• Title/Summary/Keyword: Operating system laboratory class

Search Result 6, Processing Time 0.021 seconds

Operation Results of a 5kW-Class SOFC System Composed of 2 Sub-Module Stacks (2 모듈 스택을 이용한 5kW급 SOFC 시스템 운전결과)

  • Lee, Tae-Hee;Choi, Mi-Hwa;Yoo, Young-Sung
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.5
    • /
    • pp.609-615
    • /
    • 2011
  • A 5 kW class SOFC system for cogeneration power units was consisted of a hot box part and cold BOPs. High temperature components such as a stack, a fuel reformer, a catalytic combustor, and heat exchanges are arranged in the bot box considering their operating temperatures for the system efficiency. The hot box was made of ceramic boards for the thermal insulation. A 5 kW class SOFC stack was composed of 2 sub-modules and each module had 64 cells with $15{\times}15cm^2$ area and stainless steel interconnects. The 5 kW class SOFC system was operated with a hydrogen and a city gas. With a hydrogen, the total power of the stacks was about 7.1 kWDC and electrical efficiency was about 49.3% at 80 A. With a city gas, the total power of the stacks was about 5.7 $kW_{DC}$ and electrical efficiency was about 38.8% at 60 A. Under self-sustained operating condition, the system efficiency including a power conditioning loss and a consumed power by BOPs was about 30.2%.

A Case Study on the Ventilation System of the General hospital (종합병원의 환기설비 사례 연구)

  • Jung, Jong-Rim
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.

Effects of Reciprocal Peer Tutoring on Academic Achievement and Satisfaction: Focused on Application Practices in Computer Operating System Lab Education (상호 동료 교수법이 학업성취도와 만족도에 미치는 영향에 관한 연구: 컴퓨터 운영체제 실습 수업 적용 방안을 중심으로)

  • Lee, Manhee
    • The Journal of Korean Association of Computer Education
    • /
    • v.16 no.3
    • /
    • pp.61-70
    • /
    • 2013
  • In order to increase students' academic achievement effectively and at the same time to draw active participations from students during the computer lab, we applied the reciprocal peer tutoring education model. We focused on a short-term application of the reciprocal peer tutoring to computer operating system lab education with as little preparation as possible. 61 college students majoring in computer engineering participated in this research; half of them studied in the reciprocal peer tutoring setting, and rest of them did in the normal lab setting. Results show that students who participated in the reciprocal peering tutoring lab have higher academic achievement and better satisfaction on overall education and the class's professor. We hope that our method will be easily used in other universities' computer lab education.

  • PDF

Damping Properties of a Superconductor Bearing in a 35 kWh Class Superconductor Flywheel Energy Storage System (35 kWh급 플라이휠용 초전도 베어링의 댐핑 특성평가)

  • Park, B.J.;Jung, S.Y.;Han, S.C.;Han, S.J.;Lee, D.H.;Han, Y.H.
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.66-70
    • /
    • 2012
  • Superconductor flywheel energy storage system (SFESs) is an electro-mechanical battery with high energy storage density, long life, and good environmental affinity. SFESs have been developed for application to a regenerative power of train, the storage of distributed power sources such as solar and wind power, and a power quality improvement. As superconductor bearing is completely passive, it is not necessary to control a system elaborately but accurate analysis in mechanical properties of the HTS bearing is very important for application to SFESs. Stiffness and damping properties are the main index for evaluation the capacity of HTS bearings and make it possible to adjust rotordynamic properties while operating the rotor-bearing system. The superconductor bearing consists of a stator containing single grain YBCO bulks, a ring-type permanent magnet rotor with a strong magnetic field that can reach the bulk surface, and a bearing support for assembly to SFESs frame. In this study, we investigated the stiffness and damping properties of superconductor bearings in 35 kWh SFESs. Finally, we found that 35 kWh superconductor bearing has uniform stiffness properties depend on the various orientations of rotor vibration. We discovered total damping coefficient of superconductor bearing is affected by not only magnetic damping in superconductor bulk but also external damping in bearing support. From the results, it is confirmed that the conducted evaluation can considerably improve energy storage efficiency of the SFESs, and these results can be used for the optimal capacity of superconductor bearings of the SFESs.

Vibration Monitoring and Analysis of a 6kW Wind Stand Alone Turbine Generator (6kW 독립형 풍력발전기의 진동 모니터링 및 분석)

  • Kim, Seock-Hyun;Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jeong-Wan;Park, Mu-Yeol;Park, Hae-Gyun;Kim, Tae-Hyeong
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.81-86
    • /
    • 2005
  • A vibration monitoring system for a small class of wind turbine (W/T) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW W/T generator is investigated. Acceleration data of the W/T tower under various operation condition is acquired in real time using LabVIEW and is remotely transferred from the test site to the laboratory in school by internet. Vibration state of the tower structure is diagnosed within the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site.

  • PDF

Development of SaaS cloud infrastructure to monitor conditions of wind turbine gearbox (풍력발전기 증속기 상태를 감시하기 위한 SaaS 클라우드 인프라 개발)

  • Lee, Gwang-Se;Choi, Jungchul;Kang, Seung-Jin;Park, Sail;Lee, Jin-jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.316-325
    • /
    • 2018
  • In this paper, to integrate distributed IT resources and manage human resource efficiently as purpose of cost reduction, infrastructure of wind turbine monitoring system have been designed and developed on the basis of SaaS cloud. This infrastructure hierarchize data according to related task and services. Softwares to monitor conditions via the infrastructure are also developed. Softwares are made up of DB design, field measurement, data transmission and monitoring programs. The infrastructure is able to monitor conditions from SCADA data and additional sensors. Total time delay from field measurement to monitoring is defined by modeling of step-wise time delay in condition monitoring algorithms. Since vibration data are acquired by measurements of high resolution, the delay is unavoidable and it is essential information for application of O&M program. Monitoring target is gearbox in wind turbine of MW-class and it is operating for 10 years, which means that accurate monitoring is essential for its efficient O&M in the future. The infrastructure is in operation to deal with the gearbox conditions with high resolution of 50 TB data capacity, annually.