• Title/Summary/Keyword: Operating point loss

Search Result 119, Processing Time 0.03 seconds

Centralized Control Algorithm for Power System Performance using FACTS Devices in the Korean Power System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Chang, Byung-Hoon;Myung, Ro-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 2010
  • This paper presents a centralized control algorithm for power system performance in the Korean power system using Flexible AC Transmission Systems (FACTS) devices. The algorithm is applied to the Korean power system throughout the metropolitan area in order to alleviate inherent stability problems, especially concerns with voltage stability. Generally, control strategies are divided into local and centralized control. This paper is concerned with a centralized control strategy in terms of the global system. In this research, input data of the proposed algorithm and network data are obtained from the SCADA/EMS system. Using the full system model, the centralized controller monitors the system condition and decides the operating point according to the control objectives that are, in turn, dependent on system conditions. To overcome voltage collapse problems, load-shedding is currently applied in the Korean power system. In this study, the application of the coordination between FACTS and switch capacitor (SC) can restore the solvability without load shedding or guarantee the FV margin when the margin is insufficient. Optimal Power Flow (OPF) algorithm, for which the objective function is loss minimization, is used in a stable case. The results illustrate examples of the proposed algorithm using SCADA/EMS data of the Korean power system in 2007.

Study on the Application of the Electric Drive System of Fuel Pump for Diesel Engine of Commercial Vehicle using HILS (HILS기반 상용차 디젤엔진용 연료펌프의 전기구동 시스템 적용에 관한 연구)

  • Ko, Youngjin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.166-174
    • /
    • 2014
  • Fuel injection pressure has steadily increased in diesel engines for the purpose of improving fuel efficiency and cleaning exhaust gas, but it has now reached a point, where the cost for higher pressure does not warrant additional gains. Common rail systems on modern diesel engines have fuel pumps that are mechanically driven by crankshaft. The pumps actually house two pumping module inside: a low pressure pump component and a high pressure pump component. Part of the fuel compressed by the low pressure component returns to the tank in the process of maintaining the pressure in the common rail. Since the returning fuel represents pumping loss, fuel economy improves if the returned fuel can be eliminated by using a properly controled electrical fuel pump. As the first step in developing an electrical fuel pump the fuel supply system on a 6 liter diesel engine was modeled with AMESim to analyze the workload and the fuel feed rate of the injection pump, and the results served as basis for selecting a suitable servo motor and a reducer to drive the pump. A motor controller was built using a DSP and a program which controls the common rail pressure using a proportional control method based on the target fuel pressure information from the engine ECU. A test rig to evaluate performance of the fuel pump is implemented and used to show that the newly developed electrically driven fuel pump can satisfy the fuel flow demand of the engine under various operating conditions when the rotational speed of the pump is adequately controlled.

Analysis Scheme on Backup Files of Samsung Smartphone available in Forensic (포렌식에서 활용 가능한 삼성 스마트폰 백업 파일 분석 기법)

  • Lee, Gyuwon;Hwang, Hyunuk;Kim, Kibom;Chang, Taejoo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.8
    • /
    • pp.349-356
    • /
    • 2013
  • As various features of the smartphone have been used, a lot of information have been stored in the smartphone, including the user's personal information. However, a frequent update of the operating system and applications may cause a loss of data and a risk of missing important personal data. Thus, the importance of data backup is significantly increasing. Many users employ the backup feature to store their data securely. However, in the point of forensic view these backup files are considered as important objects for investigation when issued hiding of smartphone or intentional deletion on data of smartphone. Therefore, in this paper we propose a scheme that analyze structure and restore data for Kies backup files of Samsung smartphone which has the highest share of the smartphone in the world. As the experimental results, the suggested scheme shows that the various types of files are analyzed and extracted from those backup files compared to other tools.

The calculation and Measurement Methods for G/T of the Telemetry Small Aperture Antenna (원격자료수신장비 소형반사판 안테나 G/T 예측 및 측정)

  • Kim, Chun-Won;An, Na-Gyun;Kim, Dong-Hyun;Cho, Byung-Lok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.9
    • /
    • pp.657-662
    • /
    • 2022
  • In this paper, the calculation using simulation and two measurement methods for G/T of the telemetry are analyzed. Antenna gain and noise temperature are calculated by using ICARA and Antenna Noise Temperature Calculator. System G/T were calculated by using Antenna gain/noise temperature, LNA gain/noise temperature, cable loss. The first G/T measurement method is Y-factor measurement method, which is to calculate G/T by comparing LNA noise temperature and a signal level difference when an antenna and a 50ohm termination are respectively connected to an LNA input terminal Second method is Solar calibration measurement method that is to calculate G/T by comparing noise level difference when looking at the sun and lowest level point. Finally, the accuracy was reviewed by comparing the G/T calculation results with the two measurement methods, and the optimal measurement method according to antenna performance and operating environment was presented.

Effects of inlet working condition and heat load on supercritical CO2 compressor performance

  • Jinze Pei;Yuanyang Zhao;Mingran Zhao;Guangbin Liu;Qichao Yang;Liansheng Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2812-2822
    • /
    • 2023
  • The supercritical carbon dioxide (sCO2) Brayton power cycle is more effective than the conventional power cycle and is more widely applicable to heat sources. The inlet working conditions of the compressor have a higher influence on their operating performance because the thermophysical properties of the CO2 vary dramatically close to the critical point. The flow in the sCO2 compressor is simulated and the compressor performance is analyzed. The results show that the sCO2 centrifugal compressor operates outside of its intended parameters due to the change in inlet temperature. The sCO2 compressor requires more power as the inlet temperature increases. The compressor power is 582 kW when the inlet temperature is at 304 K. But the power is doubled when the inlet temperature increases to 314 K, and the change in the isentropic efficiency is within 5%. The increase in the inlet temperature significantly reduces the risk of condensation in centrifugal compressors. When the heat load of the sCO2 power system changes, the inlet pressure to the turbine can be kept constant by regulating the rotational speed of compressors. With the increase in rotational speed, the incidence loss and condensation risk increase.

The Optimum Operating Conditions of Indented-Cylinder Length Grader to Remove Broken Rice based on Varietal Characteristics (벼 품종별 입형분리기 최적 가동조건)

  • Lee, Choon-Ki;Song, Jin;Yun, Jong-Tag;Seo, Jong-Ho;Lee, Jae-Eun;Kim, Jung-Tae;Jeong, Gun-Ho;Kim, Chung-Kon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.4
    • /
    • pp.366-374
    • /
    • 2009
  • To determine the optimum operating conditions of the indented cylinder length grader based on varietal characteristics, broken rice removal capabilities were measured on the milled rice of 41 varieties at different conditions consisted of 3 types of indented cylinders with different indent-opening diameters and 3 different collecting-angles of broken rice. The broken rice removal capabilities were swayed by the indent's opening diameter and depth as well as the angle of the collecting trough of broken rice on the point of instrument, and by the kernel length and width as well as 1000 grain weight of milled rice on the point of rice variety. When the angle of broken rice collecting-trough reached to near the horizontal center line of the indented cylinder on the direction of upward turning side, which was referred $0^{\circ}$ in this paper, the amount of rice collected in trough increased, whereas the loss of head rice also increased. Considering the removal rate of broken rice as well as loss of head rice, it was thought that the suitable angle of trough for broken rice collecting was located $5^{\circ}$ to $15^{\circ}$ depending on varietal characteristic and indent opening diameter. It was thought that 4.2 mm or more of indent opening diameter was recommendable for the rice varieties having heavier 1000 grain weight than 22.3g, as well as larger sizes than 2.9 and 5.2 mm in width and length of rice kernel, respectively; 3.8 mm for the small-sized thin kernels, and a proper diameter between 3.8 and 4.2 mm for short to middle kernels. The varieties with relatively shorter length compared to width of kernel were more difficult to separate the broken rice than the opposite ones. For effective separation of that, it seems that some specific indent shapes such as wider opening and shallow depth etc. are required. When the broken rice content were excessively high, wider diameters of indent openings than specified sizes were thought to be the better.

An Analytic Case Study on the Management of an Upper-level General Hospital(2010-2012)

  • Park, Hyun-Suk;Lee, Jung-Min;Baek, Hong-Suck;Lee, Jun-Ho;Park, Sang-Sub
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • Purpose. For a more efficient hospital management, this study aims to provide basic data so that the hospital management and staff in charge of hospital administration may systematically classify and collect hospital information, by analyzing the ordinary characters of an upper-level general hospital system and its common-type balance sheet, common-type profit and loss statement and financial ratio. Methods. By using information about an upper-level general hospital in C Province, provided by Alio(www.alio.go.kr), a public organization information provision site, Health Insurance Review & Assessment Service(www.hira.or.kr) and Ministry of Health and Welfare(www.mw.go.kr), this study analyzed 3 year's data from 2010 to 2012 and provided basic data by analyzing the ordinary characters of an upper-level general hospital system, and its common-type balance sheet, common-type profit and loss statement and financial ratio. Results. After analyzing the ordinary characters, common-type balance sheet, common-type proft and loss statement and financial ration of this general hospital, based on the 2010 to 2012 data, this study came to the following conclusions. Firstly, out of all the 1,069 hospital staff, there were 272 doctors working for 24 medical departments, out of whom the majority was 33 physicians. Most of the nurses were third-class ones, and about 2,000 outpatients and 600 inpatients on average were treated per day. Secondly, as a result of analyzing the common-type balance sheet, this study discovered that intangible assets out of fixed assets accounted for 41%, the majority, out of which usable and profitable donation asset buildings were of great importance, and the liquid assets increased more in 2012 than 2011. In the financial structure, the ratio of liquid liabilities was over 50% out of all the liabilities in 2012, and the ratio of purchase payables was high as well. The ratio of fixed liabilities reached up to 40%, out of which the retirement benefit appropriation fund was quite high. The capital was over 80%, but the surplus was in a deficit state. Compared to the capital, the ratio of total liabilities was about 90%, which indicates the financial structure of this general hospital was vulnerable. Thirdly, as a result of analyzing the common-type profit and loss statement, this study found out that the medical profits from inpatients were higher than profits from outpatients. The material cost was related to the medical quality of this general hospital, and it was as high as 30% out of the total costs and was about 45% of the labor cost. This general hospital showed 10% in the ratio of non-medical profits, and it seemed because of government subsidies. The ratios of medical profits and current net income were gradually changing for the better in 2012, compared to 2011. Lastly, as a result of analyzing the financial ratio, it was found that the liquidity ratio kept decreasing, from 110.7% in 2010 and 102.0% in 2011 to 77.2% in 2012. Besides, it was analyzed that the liquidity ratio and the net working capital ratio greatly decreased, while the quick ratio and the liquid ratio kept decreasing. Conclusions. 1. It is necessary to take the risk management into more consideration, and particularly, it is needed to differentiate and manage the levels of risk in detail. 2. By considering the fact that investments into hospital infrastructures were mostly based on liabilities, it is needed to deal with the scale of losses when evaluating risks. 3. By reflecting the character that investments into hospital infrastructures were based on liabilities, it is necessary to consider the ratio of ordinary profits as well as the ratio of operating profits to sales, and it is also important to consider sales productivity factors, such as the sales amount per a sickbed, by comparing them with other hospitals. As for limitations of this study, there may be some problems in terms of data interpretation because of the lack of information about the number of inpatients and the number of outpatients per year, which are needed for the break-even point analysis. Besides, to suggest a direction for the improvement of hospital management through analyses, non-financial factors should be reflected, such as the trend of economy, medical policies, and politic backgrounds. However, this study only focused on the common-type balance sheet, common-type profit and loss statement and financial ratio, so this study is actually limited to generalizing all the factors by analyzing public data only.

Basic Analysis of Heat and Mass Transfer Characteristics of Tubular Membrane Humidifier for Proton Exchange Membrane Fuel Cell (이온교환막 연료전지용 원통형 막 가습기의 열 및 물질전달특성 기초 연구)

  • Bae, Ho-June;Ahn, Kook-Young;Lee, Young-Duk;Kang, Sang-Kyu;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.473-480
    • /
    • 2011
  • The proton exchange membrane (PEM) fuel cell system is critically dependent on the humidity, which should be properly maintained over the entire operating range. A membrane humidifier is used for the water management in the PEMFC because of the membrane humidifier's reliable performance and zero parasitic power loss. In the PEMFC system, the membrane humidifier is required to provide appropriate humidity for the design point of the fuel cell. Although the performance of the fuel cell depends on the performance of the humidifier, few studies have provided a systematic analysis of the humidifier. We carry out an experimental analysis of the membrane humidifier using a vapor condensation bottle. The dry air pressure, water flow temperature, and air flow rate were chosen as the operating parameters. The results show that the time constant for the dynamic response of the membrane humidifier is relatively short, but additional analysis should be carried out.

Control and Analysis of an Integrated Bidirectional DC/AC and DC/DC Converters for Plug-In Hybrid Electric Vehicle Applications

  • Hegazy, Omar;Van Mierlo, Joeri;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.408-417
    • /
    • 2011
  • The plug-in hybrid electric vehicles (PHEVs) are specialized hybrid electric vehicles that have the potential to obtain enough energy for average daily commuting from batteries. The PHEV battery would be recharged from the power grid at home or at work and would thus allow for a reduction in the overall fuel consumption. This paper proposes an integrated power electronics interface for PHEVs, which consists of a novel Eight-Switch Inverter (ESI) and an interleaved DC/DC converter, in order to reduce the cost, the mass and the size of the power electronics unit (PEU) with high performance at any operating mode. In the proposed configuration, a novel Eight-Switch Inverter (ESI) is able to function as a bidirectional single-phase AC/DC battery charger/ vehicle to grid (V2G) and to transfer electrical energy between the DC-link (connected to the battery) and the electric traction system as DC/AC inverter. In addition, a bidirectional-interleaved DC/DC converter with dual-loop controller is proposed for interfacing the ESI to a low-voltage battery pack in order to minimize the ripple of the battery current and to improve the efficiency of the DC system with lower inductor size. To validate the performance of the proposed configuration, the indirect field-oriented control (IFOC) based on particle swarm optimization (PSO) is proposed to optimize the efficiency of the AC drive system in PHEVs. The maximum efficiency of the motor is obtained by the evaluation of optimal rotor flux at any operating point, where the PSO is applied to evaluate the optimal flux. Moreover, an improved AC/DC controller based Proportional-Resonant Control (PRC) is proposed in order to reduce the THD of the input current in charger/V2G modes. The proposed configuration is analyzed and its performance is validated using simulated results obtained in MATLAB/ SIMULINK. Furthermore, it is experimentally validated with results obtained from the prototypes that have been developed and built in the laboratory based on TMS320F2808 DSP.

Performance Analysis of Shell Coal Gasification Combined Cycle systems (Shell 석탄가스화 복합발전 시스템의 성능해석 연구)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.104-113
    • /
    • 1997
  • This study aims to develop an analysis model using a commercial process simulator-ASPEN PLUS for an IGCC (Integrated Gasification Combined Cycle) system consisting a dry coal feeding, oxygen-blown entrained gasification process by Shell, a low temperature gas clean up process, a General Electric MS7001FA gas turbine, a three pressure, natural recirculation heat recovery steam generator, a regenerative, condensing steam turbine and a cryogenic air separation unit. The comparison between those results of this study and reference one done by other engineer at design conditions shows consistency which means the soundness of this model. The greater moisture contents in Illinois#6 coal causes decreasing gasifier temperature and the greater ash and sulfur content hurt system efficiency due to increased heat loss. As the results of sensitivity analysis using developed model for the parameters of gasifier operating pressure, steam/coal ratio and oxygen/coal ratio, the gasifier temperature increases while combustible gases (CO+H2) decreases throughout the pressure going up. In the steam/coal ratio analysis, when the feeding steam increases the maximum combustible gas generation point moves to lower oxygen/coal ratio feeding condition. Finally, for the oxygen/coal ratio analysis, it shows oxygen/coal ratio 0.77 as a optimum operating condition at steam/coal feeding ratio 0.2.

  • PDF