• Title/Summary/Keyword: Operating parameters

Search Result 2,148, Processing Time 0.039 seconds

A Study on the Dynamic Analysis of Micro-Grid System (Micro-Grid 시스템의 동특성 해석에 관한 기초 연구)

  • Son, Kwang-M.;Lee, Kye-B.;Jeon, In-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.543-544
    • /
    • 2007
  • Micro-grid consists of micro-sources which adopt environmentally friendly and reliable power sources with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.

  • PDF

A Study on the Characteristics of the Parameters for the Statistical Analysis of Vibration Signal by Using Bearing Wear Test (베어링 마모시험을 이용한 진동신호의 통계적 파라미터 특성연구)

  • Jun, Oh-Sung;Hwang, Cheol-Ho;Yoon, Byung-Ok;Eun, Hee-Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.5-12
    • /
    • 1989
  • This paper is concerned with the characteristics on the statistical parameters of vibration signal from bearing with changing its operating conditions as well as the spreading of faults. The rms, Kurtosis, crest factor, probability of exceedance and probability density function have been chose as the statistical parameters. To characterize of each, vibration signals have been recorded from four ball tester at different loads, operation speeds and time. The values of the statistical parameters for each frequency band have been calculated after A/D conversion and digital filtering of the recorded signals. It has been found that unlike rms values the statistical parameters such as Kurtosis etc. are almost unchanging with the change of the operating conditions such as load and speed. This suggests that the statistical parameters may be used for determining the development of faults independent of the operating conditions. In fact, the statistical parameters deviate considerably from their respective normal values when the faults developed under load conditions in the samples, conforming the suggestion.

  • PDF

A Quantitative Evaluation of Combustion Characteristics of Coke/Anthracite in an Iron Ore Sintering Bed (소결층 내 코크스/무연탄 연소 특성의 정량적 평가)

  • Yang, Won;Yang, Gwang-Hyeok;Choi, Sang-Min;Choe, Eung-Su;Lee, Deok-Won;Kim, Seong-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.33-40
    • /
    • 2004
  • Combustion of coke/anthracite in an iron ore sintering bed is characterized quantitatively by introducing newly defined parameters related to propagation and thickness of combustion zone and maximum temperature. The parameters are obtained by sintering pot experiment and I-D, unsteady numerical model which treats solid material as multiple solid phases. Experiments and calculations are performed for various major operating parameters: air inlet velocity, different type of fuels which have different reactivity and diameter of the solid fuel. Effects of the operating parameters on the productivity and quality of the sintering process are investigated and evaluated quantitatively and the results show that optimized air supply rate and diameter of anthracite for replacement of coke can be obtained. This approach can be applied to other kinds of combustors for characterization of the combustion in the solid fuel beds.

  • PDF

Selection of Operating Parameters and Management of Operation Console for Protection and Control of Steam Turbine in a Korea Standard Type Nuclear Power Plant (한국 표준형 원자력 발전소 증기터빈 보호 및 제어를 위한 운전인자 선정과 운전반 운영)

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee;Shin, Man-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • This paper contains the selection of operation parameters for protection and control of steam turbine in a Korea Standard Type Nuclear Power Plant. The safety of nuclear reactor must be ensured which generates nuclear energy and produces steam. Also, the safety of turbine, which consume the nuclear energy as a core machine, must be ensured. For the purpose of this, we describe how the operating parameters were selected, reviewed, implemented into the operator console and finally put into actual operation of the system.

Estimation of Qualities and Inference of Operating Conditions for Optimization of Wafer Fabrication Using Artificial Intelligent Methods

  • Bae, Hyeon;Kim, Sung-Shin;Woo, Kwang-Bang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1101-1106
    • /
    • 2005
  • The purpose of this study was to develop a process management system to manage ingot fabrication and the quality of the ingot. The ingot is the first manufactured material of wafers. Operating data (trace parameters) were collected on-line but quality data (measurement parameters) were measured by sampling inspection. The quality parameters were applied to evaluate the quality. Thus, preprocessing was necessary to extract useful information from the quality data. First, statistical methods were employed for data generation, and then modeling was accomplished, using the generated data, to improve the performance of the models. The function of the models is to predict the quality corresponding to the control parameters. The dynamic polynomial neural network (DPNN) was used for data modeling that used the ingot fabrication data.

  • PDF

Estimation of Parameters in a Variable Displacement Piston Pump (가변용량형 피스톤펌프의 파라미터 추정)

  • Huh J.Y.;Burton R.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.4
    • /
    • pp.9-14
    • /
    • 2004
  • An estimation technique called the Extended Kalman filter is used to estimate viscous friction, spring initial contraction, and the spring constant on the swash plate of a variable displacement pump. The feasibility of the approach was established using a simulation study. It showed that these parameters could be estimated very accurately in a reliable and independent fashion. A special experimental system was set up to facilitate the measurement of certain states to enhance the Kalman Filtering approach. The aforementioned parameters were estimated and found to be reasonably repeatable for a common operating point. It was very evident that as the operating conditions changed (i.e. temperature) so did the estimated values of certain parameters such as viscous friction. This was believed to be a good verification test for the approach.

  • PDF

Reliability Evaluation of a Microgrid Considering Its Operating Condition

  • Xu, Xufeng;Mitra, Joydeep;Wang, Tingting;Mu, Longhua
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.47-54
    • /
    • 2016
  • Microgrids offer several reliability benefits, such as the improvement of load-point reliability and the opportunity for reliability-differentiated services. The primary goal of this work is to investigate the impacts of operating condition on the reliability index for microgrid system. It relies on a component failure rate model which quantifies the relationship between component failure rate and state variables. Some parameters involved are characterized by subjective uncertainty. Thus, fuzzy numbers are introduced to represent such parameters, and an optimization model based on Fuzzy Chance Constrained Programming (FCCP) is established for reliability index calculation. In addition, we present a hybrid algorithm which combines scenario enumeration and fuzzy simulation as a solution tool. The simulations in a microgrid test system show that reliability indices without considering operating condition can often prove to be optimistic. We also investigate two groups of situations, which include the different penetration levels of microsource and different confidence levels. The results support the necessity of considering operating condition for achieving accurate reliability evaluation.

Compound effects of operating parameters on burnup credit criticality analysis in boiling water reactor spent fuel assemblies

  • Wu, Shang-Chien;Chao, Der-Sheng;Liang, Jenq-Horng
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • This study proposes a new method of analyzing the burnup credit in boiling water reactor spent fuel assemblies against various operating parameters. The operating parameters under investigation include fuel temperature, axial burnup profile, axial moderator density profile, and control blade usage. In particular, the effects of variations in one and two operating parameters on the curve of effective multiplication factor ($k_{eff}$) versus burnup (B) are, respectively, the so-called single and compound effects. All the calculations were performed using SCALE 6.1 together with the Evaluated Nuclear Data Files, part B (ENDF/B)-VII238-neutron energy group data library. Furthermore, two geometrical models were established based on the General Electric (GE)14 $10{\times}10$ boiling water reactor fuel assembly and the Generic Burnup-Credit (GBC)-68 storage cask. The results revealed that the curves of $k_{eff}$ versus B, due to single and compound effects, can be approximated using a first degree polynomial of B. However, the reactivity deviation (or changes of $k_{eff}$, ${\Delta}k$) in some compound effects was not a summation of the all ${\Delta}k$ resulting from the two associated single effects. This phenomenon is undesirable because it may to some extent affect the precise assessment of burnup credit. In this study, a general formula was thus proposed to express the curves of $k_{eff}$ versus B for both single and compound effects.

Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach (고도처리 효율 향상을 위한 통계적 접근)

  • Moon, Kyung-Sook;Min, Kyung-Sub;Kim, Seung-Min;Lee, Chan-Hyung
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

A Study on the Stability of Micro-Grid System Considering Operating Range of Micro-Sources (Micro-Source의 운전 범위에 따른 Micro-Grid 시스템 의 안정도에 관한 연구)

  • Son, Kwang M.;Lee, Kye B.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.841-847
    • /
    • 2007
  • This paper deals with the micro-grid consisting of micro-sources which adopt voltage sourced inverters with independent real and reactive power control capability for providing premium power quality. This paper presents dynamic modeling and the stable operating range of the micro-grid system varying the parameters of the micro-sources. The fundamental frequency model of the micro-source inverters are considered to form a dynamic model of the micro-grid system. Stability analysis is performed based on the linearized dynamic model of the micro-grid system. Case study results show the parameters affecting the stability of the micro-grid and the stable operating range of the micro-sources.