• Title/Summary/Keyword: Operating parameters

Search Result 2,160, Processing Time 0.035 seconds

Development of Operating Parameters for Composting of Municipal Sewage Sludge (도시 생활하수 슬러지의 퇴비화를 위한 부숙공정지표 설정)

  • Lee, Hong-Jae;Cho, Ju-Sik;Choi, Hyoung-Sub;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.382-389
    • /
    • 1997
  • To study the optimum conditions of composing with sewage sludge, the variations of temperature and $CO_2$ generation amount during composting periods were investigated. The conditions were that sewage sludge added to bulking agents such as sawdust and rice hull were used and differently treated with microorganism seeding or not, initial C/N ratio, air flow rate and initial moisture contents. The results were summarized as follows : Seeding of 5% microorganism was higher temperature than not seeding. And using rice hull as bulking agents, and adjusting 21${\sim}$22 of initial C/N ratio, $200ml/l\;{\cdot}\;min$. of air flow rate and 64${\sim}$65% of initial moisture contents were higher temperature than any other conditions. Seeding of 5% microorganism was more $CO_2$ generation amount than not seeding. And using saw dust was more $CO_2$ generation amount than using rice hull as bulking agents. In the case of initial C/N ratio, adjusting 21${\sim}$42 was also more $CO_2$ generation amount than adjusting 12${\sim}$14. Judging from the result, it should be considered that the optimum conditions of composting with sewage sludges were seeding of 5% microorganism and adjusting 21${\sim}$22 of initial C/N ratio, $200ml/l\;{\cdot}\;min$. of air flow rate and 64${\sim}$65% of initial moisture contents.

  • PDF

A Study on 3[kW] PMA-RSG Optimal Design for Mobile Power Supply (이동형 전원장치용 3[kW] PMA-RSG의 최적 설계에 대한 연구)

  • Baik, Jei-Hoon;Toliyat, Hamid A.;Kim, Nam-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.109-117
    • /
    • 2009
  • In this paper, an analytical model using equivalent magnetic circuits for the PMA-SynRG is presented. The lumped parameter model (LPM) is developed from machine geometry, stator winding and machine operating specifications. By the LPM, magnetic saturation of rotor bridges is incorporated into model and it provides effective means of predicting machine performance for a given machine geometry. The LPM is not as accurate as finite element analysis but the equivalent magnetic circuits provide fast means of analyzing electromagnetic characteristics of PMa-SynRG. It is the main advantage to find the initial design and optimum design. The initial design of PMa_RSG is performed by LPM model and FEM analysis, and the final PMA-RSG design is optimized and identified by FEM analysis considering actual machine design. The linear LPM and the nonlinear LPM are programmed using MATLAB and all of machine parameters are calculated very quickly. To verify justification of the proposed design of PMa-RSM, back-EMF is measured.

Speed Control of Marine Gas Turbine Engine using Nonlinear PID Controller (비선형 PID 제어기를 이용한 선박용 가스터빈 엔진의 속도 제어)

  • Lee, Yun-Hyung;So, Myung-Ok
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.457-463
    • /
    • 2015
  • A gas turbine engine plays an important role as a prime mover that is used in the marine transportation field as well as the space/aviation and power plant fields. However, it has a complicated structure and there is a time delay element in the combustion process. Therefore, an elaborate mathematical model needs to be developed to control a gas turbine engine. In this study, a modeling technique for a gas generator, a PLA actuator, and a metering valve, which are major components of a gas turbine engine, is explained. In addition, sub-models are obtained at several operating points in a steady state based on the trial running data of a gas turbine engine, and a method for controlling the engine speed is proposed by designing an NPID controller for each sub-model. The proposed NPID controller uses three kinds of gains that are implemented with a nonlinear function. The parameters of the NPID controller are tuned using real-coded genetic algorithms in terms of minimizing the objective function. The validity of the proposed method is examined by applying to a gas turbine engine and by conducting a simulation.

Analysis on Compatibility between wireless headset and WiFi in ISM bands (ISM 대역에서 무선 헤드셋과 WiFi 간의 양립성 분석)

  • Cho, In-Kyoung;Kim, Tae-Youn;Jang, Jae-Woong;Jang, Kyung-Duk;Moon, Guee-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.272-278
    • /
    • 2015
  • This paper analyzed interference impact between wireless headset and Wireless Fidelity which get a high possibility of simultaneously operating in the Industry Science Medical(ISM) bands. Analysis methods of Minimum Coupling Loss(MCL) and Monte Carlo(MC) were applied by using the characters and parameters referenced to Institute of Electrical and Electronic Engineers(IEEE) 802.11b. The protection distance between interferer (WiFi transmitter) and victim (Wireless headset receiver) was calculated through the MCL. The protection distance was obtained for the case of single interferer, and the maximum allowable number of multiple interferers was computed according to the cell radius of a victim system to meet 5 % below of interference probability by using a statistical analysis based on the MC method. The analysis results are expected to be used as a guideline to coexist the wireless headset and low power devices in the ISM band.

Effects of the Support and Control of Franchisors on Franchisees' Satisfaction and Response Strategies (프랜차이즈 가맹본부의 지원, 통제가 가맹점사업자의 만족 및 반응전략에 미치는 영향)

  • Kwon, Yong-Deok;Yu, Jong-Pil
    • Journal of Distribution Science
    • /
    • v.12 no.8
    • /
    • pp.43-54
    • /
    • 2014
  • Purpose - This study was based on a theoretical consideration of the structural relationship between the support and control of the franchisor and the satisfaction and strategic response (voice, loyalty, exit, neglect) of the franchisee. First, based on the preceding research, this study systematically organized the type of support and control of the franchisor. Second, the study examined the effects of a franchisor's support and control on the expectancy disconfirmation between affiliated franchisees' expectations before a franchise agreement and performance after operating an affiliated store. Third, the study looked into the effects of expectancy disconfirmation relating to a franchisor's support and control on an affiliated franchisees' general satisfaction. Fourth, this study examined the influence of the general satisfaction of a franchisee on affiliated franchisees' response strategies. Research design, data, and methodology - In this study, the population comprised the nation's franchisors, and the sample comprised franchisees conducting business in Seoul and Gyeonggi-do. A self-administered questionnaire was used; the author and examiner explained the study's parameters to the interviewees in advance, to lessen the rate of rejection of the answers and to maintain reliability. The author distributed 350 copies of the questionnaire and collected 327 copies (93.4%). The author removed 54 copies of the sample, as these copies belonged to franchisees that were not registered by the Fair Trade Commission and/or were thought to have either defects or inadequate answers. The author selected an effective sample of 273 copies to enter data and to do the statistical analysis. Results - Both a reliability analysis and a confirmatory factor analysis were performed to measure reliability and validity, and a structural equation model was used to conduct the hypothesis test and investigate the models. The hypothesis was tested (Table 5). The models had a suitable fit, for instance, χ2 = 447.663(df = 212, p = .000), χ2/df = 2.112, GFI = .881, AGFI = .858, RMR = .083, RMSEA = .067, NFI = .932, and CFI = .961. The hypothesis test results were as follows. Hypothesis 1 was accepted (C.R. = -2.339, p = .019). Hypothesis 2 was accepted (C.R. = 15.213, p = .000). Hypothesis 3 was accepted (C.R. = -2.631, p = .006). Hypothesis 4 was accepted (C.R. = 16.271, p = .000). Hypothesis 5 was accepted (C.R. = 2.391, p = .017). Hypothesis 6 was accepted (C.R. = 5.777, p = .000). Hypothesis 7 was accepted (C.R. = 17.153, p = .000). Hypothesis 8 was accepted (C.R. = 24.746, p = .000). Hypothesis 9 was accepted (C.R. = -10.150, p = .000). Hypothesis 10 was accepted (C.R. = -12.124, p = .000). Conclusions - The research results showed that expectations for a franchisor's support and control had a significant influence on expectation disconfirmation in a negative way, whereas the performance of support and control were found to have a significant influence on expectation disconfirmation in a positive way. In addition, the expectation disconfirmation of support and control was found to have a significant influence on satisfaction of franchisees in a positive way. Generally, regarding the research on control, control is found to have a negative influence on the satisfaction of franchisees, but this study proves that control is found to affect it in a positive way through conformity.

Comparison of the National Early Warning Score+Lactate score with the pre-endoscopic Rockall, Glasgow-Blatchford, and AIMS65 scores in patients with upper gastrointestinal bleeding

  • Kim, Daejin;Jo, Sion;Lee, Jae Baek;Jin, Youngho;Jeong, Taeoh;Yoon, Jaechol;Park, Boyoung
    • Clinical and Experimental Emergency Medicine
    • /
    • v.5 no.4
    • /
    • pp.219-229
    • /
    • 2018
  • Objective We compared the predictive value of the National Early Warning Score+Lactate (NEWS+L) score with those of other parameters such as the pre-endoscopic Rockall score (PERS), Glasgow-Blatchford score (GBS), and albumin, international normalized ratio, altered mental status, systolic blood pressure, age older than 65 years score (AIMS65) among patients with upper gastrointestinal bleeding (UGIB). Methods We conducted a retrospective study of patients with UGIB during 2 consecutive years. The primary outcome was the composite of in-hospital death, intensive care unit admission, and the need for ${\geq}5$ packs of red blood cell transfusion within 24 hours. Results Among 530 included patients, the composite outcome occurred in 59 patients (19 inhospital deaths, 13 intensive care unit admissions, and 40 transfusions of ${\geq}5$ packs of red blood cells within 24 hours). The area under the receiver operating characteristic curve of the NEWS+L score for the composite outcome was 0.76 (95% confidence interval, 0.70 to 0.82), which demonstrated a significant difference compared to PERS (0.66, 0.59-0.73, P=0.004), but not to GBS (0.70, 0.64-0.77, P=0.141) and AIMS65 (0.76, 0.70-0.83, P=0.999). The sensitivities of NEWS+L scores of 3 (n=34, 6.4%), 4 (n=92, 17.4%), and 5 (n=171, 32.3%) were 100%, 98.3%, and 96.6%, respectively, while the sensitivity of an AIMS65 score of 0 (n=159, 30.0%) was 91.5%. Conclusion The NEWS+L score showed better discriminative performance than the PERS and comparable discriminative performance to the GBS and AIMS65. The NEWS+L score may be used to identify low-risk patients among patients with UGIB.

Flow Diverter Devices for the Treatment of Unruptured Vertebral Artery Dissecting Aneurysm

  • Kim, Chang Hyeun;Lee, Chi Hyung;Kim, Young Ha;Sung, Soon Ki;Son, Dong Wuk;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.891-900
    • /
    • 2021
  • Objective : Vertebral artery dissecting aneurysm (VADA) is a very rare subtype of intracranial aneurysms; when ruptured, it is associated with significantly high rates of morbidity and mortality. Despite several discussions and debates, the optimal treatment for VADA has not yet been established. In the last 10 years, flow diverter devices (FDD) have emerged as a challenging and new treatment method, and various clinical and radiological results have been reported about their safety and effectiveness. The aim of our study was to evaluate the clinical and radiological results with the use of FDD in the treatment of unruptured VADA. Methods : We retrospectively evaluated the data of all patients with unruptured VADA treated with FDD between January 2018 and February 2021 at our hybrid operating room. Nine patients with unruptured VADA, deemed hemodynamically unstable, were treated with FDD. Among other parameters, the technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcomes were evaluated. Results : Successful FDD deployment was achieved in all cases, and the immediate follow-up angiography showed intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of facial numbness and palsy was noted in one patient; however, the symptoms had completely disappeared when followed up at the outpatient clinic 2 weeks after the procedure. The 3-6 months follow-up angiography (n=9) demonstrated complete/near-complete obliteration of the aneurysm in seven patients, and partial obliteration and segmental occlusion in one patient each. In the patient who achieved only partial obliteration, there was a sac 13 mm in size, and there was no change in the 1-year follow-up angiography. In the patient with segmental occlusion, the cause could not be determined. The clinical outcome was modified Rankin Scale 0 in all patients. Conclusion : Our preliminary study using FDD to treat hemodynamically unstable unruptured VADA showed that FDD is safe and effective. Our study has limitations in that the number of cases is small, and it is not a prospective study. However, we believe that the study contributes to evidence regarding the safety and effectiveness of FDD in the treatment of unruptured VADA.

The Significance of the Strong Ion Gap in Predicting Acute Kidney Injury and In-hospital Mortality in Critically Ill Patients with Acute Poisoning (중증 급성 중독 환자에서 급성 신장 손상과 병원 내 사망률을 예측하기 위한 강이온차(Strong Ion Gap)의 중요성)

  • Sim, Tae Jin;Cho, Jae Wan;Lee, Mi Jin;Jung, Haewon;Park, Jungbae;Seo, Kang Suk
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.72-82
    • /
    • 2021
  • Purpose: A high anion gap (AG) is known to be a significant risk factor for serious acid-base imbalances and death in acute poisoning cases. The strong ion difference (SID), or strong ion gap (SIG), has recently been used to predict in-hospital mortality or acute kidney injury (AKI) in patients with systemic inflammatory response syndrome. This study presents a comprehensive acid-base analysis in order to identify the predictive value of the SIG for disease severity in severe poisoning. Methods: A cross-sectional observational study was conducted on acute poisoning patients treated in the emergency intensive care unit (ICU) between December 2015 and November 2020. Initial serum electrolytes, base deficit (BD), AG, SIG, and laboratory parameters were concurrently measured upon hospital arrival and were subsequently used along with Stewart's approach to acid-base analysis to predict AKI development and in-hospital death. The area under the receiver operating characteristic curve (AUC) and logistic regression analysis were used as statistical tests. Results: Overall, 343 patients who were treated in the intensive care unit were enrolled. The initial levels of lactate, AG, and BD were significantly higher in the AKI group (n=62). Both effective SID [SIDe] (20.3 vs. 26.4 mEq/L, p<0.001) and SIG (20.2 vs. 16.5 mEq/L, p<0.001) were significantly higher in the AKI group; however, the AUC of serum SIDe was 0.842 (95% confidence interval [CI]=0.799-0.879). Serum SIDe had a higher predictive capacity for AKI than initial creatinine (AUC=0.796, 95% CI=0.749-0.837), BD (AUC=0.761, 95% CI=0.712-0.805), and AG (AUC=0.660, 95% CI=0.607-0.711). Multivariate logistic regression analyses revealed that diabetes, lactic acidosis, high SIG, and low SIDe were significant risk factors for in-hospital mortality. Conclusion: Initial SIDe and SIG were identified as useful predictors of AKI and in-hospital mortality in intoxicated patients who were critically ill. Further research is necessary to evaluate the physiological nature of the toxicant or unmeasured anions in such patients.

Prediction of Axillary Lymph Node Metastasis in Early Breast Cancer Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and Diffusion-Weighted Imaging

  • Jeong, Eun Ha;Choi, Eun Jung;Choi, Hyemi;Park, Eun Hae;Song, Ji Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.125-135
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) variables, for axillary lymph node (ALN) metastasis in the early stage of breast cancer. Materials and Methods: January 2011-April 2015, 787 patients with early stage of breast cancer were retrospectively reviewed. Only cases of invasive ductal carcinoma, were included in the patient population. Among them, 240 patients who underwent 3.0-T DCE-MRI, including DWI with b value 0 and $800s/mm^2$ were enrolled. MRI variables (adjacent vessel sign, whole-breast vascularity, initial enhancement pattern, quantitative kinetic parameters, signal enhancement ratio (SER), tumor apparent diffusion coefficient (ADC), peritumoral ADC, and peritumor-tumor ADC ratio) clinico-pathologic variables (age, T stage, multifocality, extensive intraductal carcinoma component (EIC), estrogen receptor, progesterone receptor, HER-2 status, Ki-67, molecular subtype, histologic grade, and nuclear grade) were compared between patients with axillary lymph node metastasis and those with no lymph node metastasis. Multivariate regression analysis was performed, to determine independent variables associated with ALN metastasis, and the area under the receiver operating characteristic curve (AUC), for predicting ALN metastasis was analyzed, for those variables. Results: On breast MRI, moderate or prominent ipsilateral whole-breast vascularity (moderate, odds ratio [OR] 3.45, 95% confidence interval [CI] 1.28-9.51 vs. prominent, OR = 15.59, 95% CI 2.52-96.46), SER (OR = 1.68, 95% CI 1.09-2.59), and peritumor-tumor ADC ratio (OR = 6.77, 95% CI 2.41-18.99), were independently associated with ALN metastasis. Among clinico-pathologic variables, HER-2 positivity was independently associated, with ALN metastasis (OR = 23.71, 95% CI 10.50-53.54). The AUC for combining selected MRI variables and clinico-pathologic variables, was higher than that of clinico-pathologic variables (P < 0.05). Conclusion: SER, moderate or prominent increased whole breast vascularity, and peritumor-tumor ADC ratio on breast MRI, are valuable in predicting ALN metastasis, in patients with early stage of breast cancer.

Measurement and Correlation of density and excess volume for Water+DIPA, DIPA+MDEA and Water+DIPA+MDEA systems (Water+DIPA, DIPA+MDEA, Water+DIPA+MDEA 계의 밀도와 과잉부피 측정 및 상관)

  • Kim, Jinho;Na, Jaeseok;Shin, Hun Yong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.2
    • /
    • pp.198-204
    • /
    • 2019
  • For the removal of carbon dioxide from the chemical process, a chemical absorption method is typically used industrially. Development of new processes for the removal of carbon dioxide by the chemical absorption method has been developing new absorbents by using various absorbents. Thermodynamic data of the sorbent mixture in the new process design using hybrid absorbent is essential to reduce the equipment cost and operating costs of the process. In this study, densities of water+diisopropanolamine (DIPA), DIPA+MDEA(Methyldiethanolamine) binary systems and Water+DIPA+MDEA ternary system were measured over the full range of composition at temperatures from 303.15 K to 333.15 K by using an Anton Paar digital vibrating tube densimeter (DMA4500). The experimental excess volumes have been obtained from the experimental density results and have been fitted using the Redlich-Kister-Muggianu expression. The parameters obtained from the binary excess volume data were used for the correlation of ternary system with one additional ternary parameter for each isotherm. All investigated binary and ternary systems are completely miscible, because the values of excess volume are negative under the examined conditions.