• Title/Summary/Keyword: Operating number control

Search Result 332, Processing Time 0.03 seconds

An Operating Software Development of A Prototype Coronagraph for The Total Solar Eclipse in 2017

  • Park, Jongyeob;Choi, Seonghwan;Kim, Jihun;Jang, Be-ho;Bong, Su-Chan;Baek, Ji-Hye;Yang, Heesu;Park, Young-Deuk;Cho, Kyung-Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.85.1-85.1
    • /
    • 2017
  • We develop a coronagraph to measure the coronal electron density, temperature, and speed by observing the linearly polarized brightness of solar corona with 4 different wavelengths. Through the total solar eclipse on 21 August 2017, we test an operating software of a prototype coronagraph working with two sub-systems of two motorized filter wheels and a CCD camera that are controlled by a portable embedded computer. A Core Flight System (CFS) is a reusable software framework and set of reusable software applications which take advantage of a rich heritage of successful space mission of NASA. We use the CFS software framework to develop the operating software that can control the two sub-systems asynchronously in an observation scenario and communicate with a remote computer about commands, housekeeping data through Ethernet. The software works successfully and obtains about 160 images of 12 filter sets (4 bandpass filters and 3 polarization angles) during the total phase of the total solar eclipse. For the future, we can improve the software reliability by testing the software with a sufficient number of test cases using a testing framework COSMOS. The software will be integrated into the coronagraph for balloon-borne experiments in 2019.

  • PDF

The Influence of Diffusion of New Media Platform in Production and Distribution of Contents Industry (뉴미디어 플랫폼 확산이 콘텐츠 창작 및 유통시장에 미치는 영향 분석)

  • Suh, Byung-Moon;Park, Woo-Ram
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.43-55
    • /
    • 2009
  • We consider a Direct Input Output Manufacturing System(DIOMS) which has a number of machine centers placed along a built-in Automated Storage/Retrieval System(AS/RS). The Storage/Retrieval (S/R) machine handles parts placed on pallets for the operational aspect of DIOMS and determines the optimal operating policy by combining computer simulation and genetic algorithm. The operational problem includes: input sequencing control, dispatching rule of the SIR machine, machine center-based part type selection rule, and storage assignment policy. For each operating policy, several different policies are considered based on the known research results. In this paper, using the computer simulation and genetic algorithm we suggest a method which gives the optimal configuration of operating policies within reasonable computation time.

Adaptation of the parameters of the physical layer of data transmission in self-organizing networks based on unmanned aerial vehicles

  • Surzhik, Dmitry I.;Kuzichkin, Oleg R.;Vasilyev, Gleb S.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.23-28
    • /
    • 2021
  • The article discusses the features of adaptation of the parameters of the physical layer of data transmission in self-organizing networks based on unmanned aerial vehicles operating in the conditions of "smart cities". The concept of cities of this type is defined, the historical path of formation, the current state and prospects for further development in the aspect of transition to "smart cities" of the third generation are shown. Cities of this type are aimed at providing more comfortable and safe living conditions for citizens and autonomous automated work of all components of the urban economy. The perspective of the development of urban mobile automated technical means of infocommunications is shown, one of the leading directions of which is the creation and active use of wireless self-organizing networks based on unmanned aerial vehicles. The advantages of using small-sized unmanned aerial vehicles for organizing networks of this type are considered, as well as the range of tasks to be solved in the conditions of modern "smart cities". It is shown that for the transition to self-organizing networks in the conditions of "smart cities" of the third generation, it is necessary to ensure the adaptation of various levels of OSI network models to dynamically changing operating conditions, which is especially important for the physical layer. To maintain an acceptable level of the value of the bit error probability when transmitting command and telemetry data, it is proposed to adaptively change the coding rate depending on the signal-to-noise ratio at the receiver input (or on the number of channel decoder errors), and when transmitting payload data, it is also proposed to adaptively change the coding rate together with the choice of modulation methods that differ in energy and spectral efficiency. As options for the practical implementation of these solutions, it is proposed to use an approach based on the principles of neuro-fuzzy control, for which examples of determining the boundaries of theoretically achievable efficiency are given.

The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack

  • Homma, Shin;Maeda, Junji;Hanada, Naoya
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.333-347
    • /
    • 2009
  • Many tower-supported steel stacks have been constructed in Japan, primarily for economic reasons. However the dynamic behavior of these stacks under a strong wind is not well known and the wind load design standard for this type of a stack has not yet been formulated. In light of this situation, we carried out wind response observation of an operating tower-supported steel stack with and without a tuned-mass damper. The observation revealed the performance of the tuned-mass damper installed on the stack in order to control the wind-induced vibration. Based on the observed data, we performed a wind tunnel test of a specimen of the stack. In this paper we report the results of the wind tunnel test and some comparisons with the results of observation. Our findings are as follows: 1) the tuned-mass damper installed on the specimen in the wind tunnel test worked as well as the one on the observed stack, 2) the amplitude of the vortex-induced vibration of the specimen corresponded approximately to that of the observed stack, and 3) correlation between Scruton number and reduced amplitude, y/d, (y is amplitude, d is diameter) was confirmed by both the wind tunnel test and the observed results.

Comparisons of the Particle Emission Characteristics Between GDI and MPI Vehicles (GDI와 MPI 자동차의 미세입자 배출특성 비교)

  • Lee, Jongtae;Kim, Kijoon;Kim, Jeongsoo;Jang, Jihwan;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.182-187
    • /
    • 2014
  • As the regulations for Particulate Matter (PM) and Particle Number (PN) emissions from Gasoline Direct Injection (GDI) Vehicle stringent recently, a lot of studies have been made on the emission characteristics of PM and PN. In this study, PM and PN emission characteristics were compared to GDI and Multi Port Injection (MPI) Vehicles using the Condensation Particle Counter (CPC) measurement equipment. And driving mode is divided into normal driving mode (CVS-75, NEDC, NIER 6, NIER 9) and a constant speed driving mode (10 km/h, 35 km/h, 80 km/h, 110 km/h) to evaluate the characteristics in the various operating conditions. In the results, most of the driving mode, PM and PN were emitted from GDI Vehicle more than MPI Vehicle. However, in the constant speed mode of 110 km/h, PM and PN from MPI Vehicle were also a lot of emission. It is determined to cause a difficulty in the fuel injection control of the MPI Vehicle.

NUMERICAL ANALYSIS ON THE NATURAL CONVECTION IN A LONG HORIZONTAL PIPE WITH THERMAL STRATIFICATION

  • Ahn, Jang-Sun;Park, Byeong-Ho;Kim, Seoug-Beom;Kim, Eun-Kee;Park, Man-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.95-101
    • /
    • 1996
  • In this paper, the steady 2-dimensional model for a long horizontal line with different end temperatures undergoing natural convection at very high Rayleigh number is proposed to numerically investigate the heat transfer and flow characteristics. The dimensionless governing equations are solved by using SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm which is developed using control volumes and staggered grids. The numerical results are verified by comparison with the operating PWR test data. The analysis focuses on the effects of variation of the heat transfer rates at the pipe surface, the thermal conductivities of the pipe material and the thickness of the pipe wall on the thermal stratification. The results show that the heat transfer rate at the pipe surface is the controlling parameter. A significant reduction and disappearance of thermal stratification phenomenon is observed at the Biot number of 5.0$\times$10$^{-2}$. The results also show that the increment of the thermal conductivity and thickness of the wall weakens the thermal stratification and somewhat reduces azimuthal temperature gradient in the pipe wall. Those effects are however minor, when compared with those due to the variation of the heat transfer rates at the surface of the pipe wall.

  • PDF

A Study on ICS/SCADA System Web Vulnerability (제어시스템의 웹 취약점에 대한 현황과 연구)

  • Kim, Hee-Hyun;Yoo, Jinho
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.2
    • /
    • pp.15-27
    • /
    • 2019
  • In the past, the control system was a closed network that was not connected to the external network. However, in recent years, many cases have been opened to the outside for the convenience of management. Are connected to the Internet, and the number of operating control systems is increasing. As a result, it is obvious that hackers are able to make various attack attempts targeting the control system due to external open, and they are exposed to various security threats and are targeted for attack. Industrial control systems that are open to the outside have most of the remote management ports for web services or remote management, and the expansion of web services through web programs inherits the common web vulnerability as the control system is no exception. In this study, we classify and compare existing web vulnerability items in order to derive the most commonly tried web hacking attacks against control system from the attacker's point of view. I tried to confirm.

The Development for Localizing KTX Brake Devices and Performance Test (KTX 제동장치의 국산화 개발과 성능시험)

  • So, Jin-Sub;Lee, Seung-Gu;Hwang, Sang-Kyu;Keum, Jong-Ho;Kwak, Soo-Tae;Kim, Jong-Ryeol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.630-636
    • /
    • 2011
  • Air brake system of KTX effectively distributes air to brake panel in each bogie. System consists of carrying bogie brake panel, motor bogie brake panel, driver's valve panel, pneumatic auxiliary panel and other accessories. For the prove endurance, confirm test number. Distributor and control moderable magnet valve are 500,000 times and respectively, carrying bogie MR/BP cut-out cock are 12,000 times. Tests satisfy all of condition until now. Developments conduct a performance test to brake tester of domestic manufacturer and operating authority.

  • PDF

Spectrum Reuse with Power Control for Two-Tier Femtocell Networks

  • Kim, Youngju;Wang, Hano;Hong, Daesik
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.5
    • /
    • pp.275-284
    • /
    • 2014
  • This paper considers two-tier networks consisting of macrocells and femtocells operating in the same spectrum. This paper proposes a femtocell spectrum reuse scheme that determines the shared spectrum and transmit power for the femtocells to mitigate the effects of cross-tier interference between the macrocells and femtocells. The proposed scheme provides macrocell throughput that is unaffected by the increasing number of femtocells per cell site and improves the femtocell signal quality at the same time by limiting the cross-tier interference. This study analyzed the per-tier signal-to-interference ratio (SIR) and outage probability of the proposed scheme to investigate the macrocell and femtocell performance. The total throughput of the proposed scheme was analyzed based on the outage probabilities. The analysis and numerical results proved that high femtocell throughput can be achieved using only a small fraction of the spectrum while protecting the macrocell throughput. As a result, an improved total throughput was achieved enforcing higher spatial reuse.

A Novel Hybrid Five-Level Inverter for Medium-Voltage Applications (중전압 응용을 위한 새로운 하이브리드 5-레벨 인버터)

  • Dao, Ngoc Dat;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.485-486
    • /
    • 2016
  • This paper proposes a new hybrid five-level voltage-source inverter topology, based on the conventional five-level active neutral-point-clamped topology (5L-ANPC), where the lower number of switching devices is required, resulting in saving the cost. The operating principle and control method of the proposed topology is described. The comparison of THD, power losses, loss distribution, and cost of components are evaluated among the proposed topology, the 5L-ANPC and 5L-DCI (diode-clamped inverters) topology.

  • PDF