• Title/Summary/Keyword: Operating mode

Search Result 1,466, Processing Time 0.034 seconds

Investigation on vapor-cooled current leads operating in pulse mode (펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구)

  • 인세환;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

Instantaneous sinusoidal currant tracking mode inverter with quasi-resonant Link in DC side (공진 DC Link 순시 정현파 전류 추종형 인버터를 이용한 유도전동기 제어시스템)

  • Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.324-327
    • /
    • 1990
  • In this paper describes the feasibility study on a single-phase / three-phase voltage-fed inverter using 1GBTs, incorporating voltage-mode quasi-resonant DC Link and the instantaneous Sinusoidal Current tracking adaptive control implementation under zero voltage switching resfriction. The simulation and experimental results are shown here and discussed for single-phase voltage-fed and three-phase voltage-fed inverter in order to verify the new operating principle of the Inverter topology proposed here.

  • PDF

Ultra-Low-Power Differential ISFET/REFET Readout Circuit

  • Thanachayanont, Apinunt;Sirimasakul, Silar
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.243-245
    • /
    • 2009
  • A novel ultra-low-power readout circuit for a pH-sensitive ion-sensitive field-effect transistor (ISFET) is proposed. It uses an ISFET/reference FET (REFET) differential pair operating in weak-inversion and a simple current-mode metal-oxide semiconductor FET (MOSFET) translinear circuit. Simulation results verify that the circuit operates with excellent common-mode rejection ability and good linearity for a single pH range from 4 to 10, while only 4 nA is drawn from a single 1 V supply voltage.

  • PDF

Building Blocks for Current-Mode Implementation of VLSI Fuzzy Microcontrollers

  • Huerats, J.L.;Sanchez-Solano, S.;Baturone, I.;Barriga, A.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.929-932
    • /
    • 1993
  • A fuzzy microcontroller is presented implementing a simplified inference mechanism. Fuzzification, rule composition and defuzzification are carried out by means of (basically) analog current-mode CMOS circuits operating in strong inversion. Also a voltage interface is provided with the external world. Combining analog and digital techniques allow a programming capability.

  • PDF

Nano-particles emission characteristics of GDI vehicles using Engine Exhaust Particle Sizer (Engine Exhaust Particle Sizer를 통한 GDI 자동차에서 발생하는 나노미세입자 배출특성 분석)

  • Jang, Jihwan;Lee, Jongtae;Kim, Kijoon;Kim, Jeongsoo;Park, Sungwook
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.95-96
    • /
    • 2014
  • In this study, the nano-particle emitted from Gasoline Direct Injection(GDI) vehicles was measured using the Engine Exhaust Particle Sizer(EEPS) on a chassis dynamometer. In addition, driving mode were divided into cold start mode(CVS-75, NEDC) and hot start mode(NIER-6, NIER-9) to evaluated the characteristics in the various operating conditions. The Particle Number(PN) concentration was analyzed for various driving patterns, i.e., acceleration, deceleration, idling, cruising and the phases of mode. In a result, Total concentration of PN for size was concentrated from 50 to 100 nm and acceleration represents the highest concentration among the driving pattern. It is believed that the increases quantity of fuel, and mixture will be richer than other patterns.

  • PDF

A Study on Particle Displacement Distributions of Energy-trapped Piezoelectric Resonators and Filters Utilizing the Harmonic Modes (고차진동을 이용하는 에너지포획형 압전 공진자와 필터의 변위분포에 관한 연구)

  • 이개명
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.954-962
    • /
    • 1998
  • Energy-trapped thickness vibrations of piezoelectric substrates are utilized in fabricating resonators and filters which have their operating frequencies in HF band. Normalized particle displacement distributions of the fundamental thickness shear vibration mode and overtone modes into the thickness direction in energy-trapped resonators and double-coupled filters were obtained by solving the wave equation and calculating the solved equations. These results show that as the number order of the harmonic mode in a energy-trapped resonator becomes larger, the degree of energy-trapping in the resonator increase, and if the conditions for energy-trapping become sufficiently weak, the energy-trapping effect of the harmonic mode which has the lower order disappears the earlier. Above simulation results were proved by the experiments.

  • PDF

Simulation on a Residential Heat Pump System Using $CO_2$ (이산화탄소를 적용한 주거용 냉난방 겸용 열펌프 시스템의 시뮬레이션)

  • 조홍현;이무연;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.987-995
    • /
    • 2003
  • The performance of a residential heating and cooling system with $CO_2$ is predicted by using a cycle simulation model. The simulations are conducted by varying design parameters and operating conditions. The efficiency of the transcritical cycle can be improved by utilizing the advantages in heat transfer characteristics of $CO_2$ and developing microchannel indoor and outdoor heat exchangers. For the designed system of this study, the predicted COP of the heat pump system is approximately 3.5 in the heating mode and 3.0 in the cooling mode. The predicted optimal discharge pressure for the heat pump system is approximately 11 MPa in the heating mode and 9 MPa in the cooling mode.

A High-speed 8-Bit Current-Mode BICMOS A/D Converter (BICMOS를 이용한 전류형 고속 8비트 A/D변환기)

  • Han, Tae-Hi;Cho, Sang-Woo;Lee, Heui-Deok;Han, Chul-Hi
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.857-860
    • /
    • 1991
  • This paper describes a High-Speed 8-bit Current-Mode BiCMOS A/D Converter. The characteristics of this A/D Converter are as fellows. First, as ADC is operating in current-mode we can obtain the properties of increase of converting speed, low noise, and wideband. Second, the properties of high switching speed in bipolar transistor and of high packing density, low power consumption in MOS trnsistor are combined. Finally we reduce chip area by designing it with subranging mode and improve the converting speed by performing subtraction directly, which doesn't need D/A convertings, using current switching element. This converter is composed of two 4-bit ADC, current soure array which provides signal and reference current, current comparator and encoding network.

  • PDF

Operating Characteristics Analysis of Bidirectional DC/DC Converter in Idling Mode of Fuel Cell - Supercapacitor Combined System (연료전지와 슈퍼커패시터가 결합된 발전시스템의 대기모드에서 양방향 DC-DC 컨버터의 특성해석)

  • Lee, Jong-Gyu;Song, Woong-Hyub;Kim, Jin-Young;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.13-14
    • /
    • 2011
  • This paper deals with the ZVS characteristics of a bidirectional DC/DC converter in idling mode. Simulations are carried out with the supercapacitor which maximum voltage is 50 V. It is found that the ZVS can be achieved as far as the supercapacitor voltage is below 94% of the maximum voltage in idling mode. Therefore, the switching loss in the mode can be small by control the upper limit of the supercapacitor voltage.

  • PDF

An Optimal Block Replacement Policy Using Items with Different Reliability

  • Lie, Chang-Hoon;Bae, Moon-Sik;Chun, Young-Ho
    • Journal of the military operations research society of Korea
    • /
    • v.10 no.2
    • /
    • pp.61-73
    • /
    • 1984
  • A block replacement policy using items with different reliability is discussed. We divide system unit failure modes into two modes and use less reliable unit when operating unit fails near the planned preventive replacement time. In this policy, item A has two failure modes. Mode-1 failure is removed by minimal repair, mode-2 failure by replacement. If mode-2 failure of item A happens in (0, $T-{\delta}$), failure item A is replaced by new item A. If mode-2 failure of item A happens in ($T-{\delta}$, T), failure item A is replaced by new item B. Item B should be cheaper and less durable than item A. Under this policy, we determine the preventive replacement interval $T^{*}$ and the interval ${\delta}^{*}$ of item B replacement which minimize the cost rate per unit time.

  • PDF