• 제목/요약/키워드: Operating mode

검색결과 1,466건 처리시간 0.031초

ESS 기능을 갖는 단상 이중변환 UPS (Single-Phase Double-Conversion UPS with Energy Storage System)

  • 임승범;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.137-138
    • /
    • 2013
  • This paper proposes the single-phase double-conversion UPS(Uninterruptible Power Supply) with ESS(Energy Storage System). The Proposed system is operating in three modes, which are normal mode, battery mode, and bypass mode. Not only in black-out but also in peak load times, the system is operating in battery mode which is using the stored energy of the battery to manage the power effectively. The validity of proposed system could be verified by simulations and experiments.

  • PDF

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

FreeBSD 커널 기반의 침입 차단 시스템 성능 분석 (A Performance Analysis of Firewall on the FreeBSD Kernel)

  • 박창서
    • 한국정보통신학회논문지
    • /
    • 제7권8호
    • /
    • pp.1726-1731
    • /
    • 2003
  • 인터넷을 통해서 침입하는 해커나 침입자로부터 기관의 내부 정보시스템을 보호하기 위하여 침입 차단 시스템(firewall)의 사용이 보편화되고 있다. 하지만 사용자 입장에서는 침입 차단 시스템의 성능을 확인 할 수 없을 뿐 아니라, 동작 모드(브리지 모드(Bridge Mode), 게이트웨이 모드(Gateway Mode))에 따른 성능 차이를 알 수 없다. 이러한 문제를 해결하기 위하여 본 논문에서는 침입 차단 시스템의 운영체제(Windows 2000, Linux, FreeBSD) 환경에 따른 성능을 분석하였다. 끝으로 FreeBSD 커널 기반의 침입 차단 시스템을 서로 다른 동작 모드에서 성능을 비교하고 침입 차단 정책 수가 성능에 미치는 영향에 대하여 분석하였다.

CVT의 변속 알고리듬과 응답특성 (Shifting Algorithm and Response Characteristics of CVT)

  • 성덕환;김현수
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.9-17
    • /
    • 1994
  • In this study, a shifting algorithm of CVT was suggested for the two(2) driving modes : (1) power mode and (2) economy mode. Shifting algorithm must be obtained to make the engine run on the optimum operating line for the desired performance of the vehicle. Optimum operating lines of the engine were obtained by connecting the shortest way of the iso-power lines for the power mode and by connecting the shortest way of the BSFC curves for the economy mode. Also dynamic model of CVT vehicle was derived considering the throttle and the brake operation. By using the shifting algorithm and the CVT vehicle model, numerical simulations were performed to estimate the performance of CVT. Simulation results showed that comparing the performance of the conventional 4-speed automatic transmission, acceleration performance of the CVT vehicle was almost same with the AT vehicle for the power mode and the fuel economy of CVT was 14% superior than that of AT for the economy mode.

  • PDF

임계모드에서 동작하는 단일 전력단을 갖는 고역률 형광등용 전자식 안정기에 관한 연구 (Study of Single-Stage High-Power-Factor Electronic Ballast for fluorescent lamps operating in critical conduction mode)

  • 서철식;김동희;변영복;이봉섭;심광열;오승훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1126-1128
    • /
    • 2001
  • A single-stage high-power-factor electron ic ballast operating in critical conduction mode is presented in this paper. The proposed topology is based on integration of a boost-like converter and a LCC Type half-bridge serial resonant inverter. The power-factor-correction(PFC) stage is a boost-like converter operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency (60Hz) so that a high power factor is achieved naturally. The simulated and experimental results for 100w fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained.

  • PDF

3-Phase Quasi-Resonant Inverter의 동작모드 확장 (Expansion of Operating Mode of 3-Phase Quasi-Resonant DC Link Inverter)

  • 양순배;이진우;박민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-271
    • /
    • 1990
  • This paper describes a 3-Phase Quasi-Resonant DC Link Inverter (3-phase QRI), which has two operating modes, ie. inverting mode and rectifying mode. First the 3-Phase QRI is simplified and the resonant circuit is analyzed in comparison with two resonant DC-to-DC converters. This analysis shows that the maximum voltage of resonant capacitor is limited to twice the input voltage irrespective of operating modes. A new simple control method in rectifying mode is suggested, which does not require any other element in power circuit. The characteristic of 3-Phase Quasi Resonant Inverter has been verified by simulation using the proposed control method.

  • PDF

새로운 3상 준공진 직류링크 인버터 (A Novel Three-Phase Quasi-Resonant DC Link Inverter)

  • Lee, Jin-Woo;Park, Min-Ho;Won, Jong-Soo
    • 대한전기학회논문지
    • /
    • 제40권5호
    • /
    • pp.479-488
    • /
    • 1991
  • A novel three-phase quasi-resonant dc link inverter (QRI)with a switch connected between dc voltage source and resonant inductor is proposed. According to the state of switching and load current, the operating mode of the proposed inverter scheme is classified into free-wheeling, inverting, and rectifying mode. By examining the behavior of the circuit in each operating mode, an equivalent circuit which represents all the modes in a unified manner is derived. The operating principle of QRI at inverting mode is analyzed, and it is shown that the maximum voltage of resonant dc link is confined to twice the dc source voltage and that both the zero voltage switching of inverter and the zero current switching of inserted switch are guaranteed. An appropriate current control algorithm is suggested, and the opeating characteristics of proposed resonant inverter are verified through both simulation and experiment.

  • PDF

동적계획법을 이용한 발전기의 운전모드 및 최적부하 배분에 관한 연구 (A Study on Optimal Electric Load Distribution and Generator Operating Mode Using Dynamic Programming)

  • H-H Yoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.313-319
    • /
    • 2002
  • Since the oil crisis in 1970, a great deal of effort has been made to develop automatic electric load sharing systems as a part of the efforts to save energy. A large scale electric generating system composes more than two generators whose characteristics may be different. When such a system is operated individually or in parallel, the lagrange multiplier's method has difficulty in achieving optimal load distribution because generators usually have the limitations of the operating range with inequality constraints. Therefore, a suitable operating mode of generators has to be decided according to the selection of the generators to meet electric power requirements at the minimum cost. In this study, a method which solves the optimal electric load distribution problem using the dynamic programming technique is proposed. This study also shows that the dynamic programming method has an advantage in dealing with the optimal load distribution problem under the limitations of the operating range with inequality constraints including generator operation mode. In this study, generator operating cost curve of second order equation by shop trial test results of diesel generators are used. The results indicate that the proposed method can be applied to the ship's electric generating system.

스마트 운영 모드를 활용한 농업용 방제 드론의 특성 분석에 관한 실험적 검증 (Experimental Verification of the Characteristic Analysis of the Aricultural Drone using Smart Operating Mode)

  • 이우람
    • 문화기술의 융합
    • /
    • 제9권6호
    • /
    • pp.1049-1055
    • /
    • 2023
  • 농업용 드론을 이용한 방제 작업의 경우 그 경제적 효율성으로 인해 활용도가 증가하고 있으나, 작업자의 숙련도에 따라 효과의 차이가 발생한다. 이에 본 연구에서는 스마트 운영 모드를 적용하여, 수동 비행 모드에서 제어의 단점을 보완하고 이에 대한 수치적 모델을 제안하고, 선행 연구와 비교 검증을 통해 실험적 검증을 수행하였다. 그 결과 농업용 방제 드론들의 분사 시간 및 방제면적을 도출하였고, 수치적 모델과 유사성이 높은 방제용 드론을 선정하여 실험적으로 검증하였다. 이를 통해 수동 비행 모드보다 스마트 운영 모드 적용 시 살포 면적 및 작업(살포 균일도 및 작업 효율)이 상대적으로 효과적인 것을 확인하였다.