• Title/Summary/Keyword: Operating method

Search Result 6,063, Processing Time 0.032 seconds

Estimation of Insulated-gate Bipolar Transistor Operating Temperature: Simulation and Experiment

  • Bahun, Ivan;Sunde, Viktor;Jakopovic, Zeljko
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.729-736
    • /
    • 2013
  • Knowledge of a power semiconductor's operating temperature is important in circuit design and converter control. Designing appropriate circuitry that does not affect regular circuit operation during virtual junction temperature measurement at actual operating conditions is a demanding task for engineers. The proposed method enables virtual junction temperature estimation with a dedicated modified gate driver circuit based on real-time measurement of a semiconductor's quasi-threshold voltage. A simulation was conducted before the circuit was designed to verify the concept and to determine the basic properties and potential drawbacks of the proposed method.

Study on the optimum system operation by considering the spinning reserve power (순동예비력을 고려한 계통의 최적운용방식에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.24 no.5
    • /
    • pp.97-102
    • /
    • 1975
  • This paper describes the result of a Study for the Optimum Operating method with Spinning reserve in case of outage of large generator unit to improve the system stability and prevent the system frequency drop. This is usually done by governor free operation, so we focused our attention to the operating Char acteristics of spinning reserve. Nexy, a study was made to mesure the upper limit of Spinning reserve and when this upper limit cannot match the required power, a relationship between the amount of spinning reserve and that of the load shedding requirement was searched with regard to several system operating conditions to use it in our future system operation. By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

A Clinical Experience of Cleft Palate Repair Using Operative Microscope: Sommerlad's Method (Sommerlad씨 술식에 따른 미세수술 술기를 이용한 구개성형술의 경험)

  • Park, Myong Chul;Shin, Seung Jun;Lee, Il Jae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • The purpose of this study is to introduce the method of palate repair that combines minimal hard palate dissection and radical retropositiong of levator musculature, which was presented by Sommerlad. As this method presents, additional use of the operating microscope enables atraumatic and radical dissection, and it might provide more improved speech function to the patients. A total of 17 patients with cleft palate underwent Sommerlad's method from December 2003 to August 2004. The mean follow-up period was 4.5 months. The use of a microscope provided high quality variable magnification and good illumination at the operating field. Repair was carried out through incisions at the margins of cleft with mucoperiosteal flap elevation. Muscles were rearranged and repaired properly. It was unable to evaluate the improvement of speech because the patients were too young to learn meaningful speech. Average operating time including anesthetic induction time, V-tube insertion and recovery from anesthesia was 2 hours 45 minutes which was not quite different from conventional method's operating time. Oronasal fistula developed in 2 patients of them. One of them was healed spontaneously. As meticulous and radical muscle dissection was possible with Sommerlad's method, we could minimize the trauma to the muscular and neurovascluar structure. In addition, we expect better faculty of speech as a result of this method although longer follow-up time was unavailable.

The Protection Method against the Operation under Unbalance Voltage in 3-phase Squirrel-Cage Induction Motor (3상절형유도전동기의 불평형운전에 대한 보호 방안)

  • 이은욱;박윤호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.281-288
    • /
    • 1984
  • A new method of protecting 3-phase squirrel-cage induction motor aginst burning-out by unbalance operation is proposed. This paper studied various kinds of situations occurred by unbalance operating in 3-phase induction motor, and we provided the search coils in the slots of stator and rotor for the purpose of detecting electrical phenpmena during unbalance operation. Through experiments, we find that search coils in the slots of stator is effective method for protecting the induction motor from unbalance operating.

  • PDF

Analysis of Core Interventions of Operating Room using Nursing Intervention Classification (NIC간호중재분류체계를 이용한 수술실 핵심간호중재분석)

  • Lee, Yoon-Young;Park, Kwang-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.3
    • /
    • pp.361-372
    • /
    • 2002
  • Purpose : The purpose of study was to identify to analysis of core nursing interventions performed by Operating Room nurses. Method : The subjects of the study were arbitrarily selected nurses(n=104) working in Operating Room. The period for data collection was 15 days from July, 15, 2002 to July, 30. 2002. The instrument for study was 486 Nursing Interventions Classification developed by McClosky & Bulechek(2000) and was translated into Korean. In 486 nursing interventions, 57 nursing interventions were selected by more than half of 47 professional nurses group of Operating Room. 57 nursing interventions were used as a secondary questionnaire. In the secondary questionnaire, labels and definitions of all 57 interventions were listed. The collected data were self reported by Operating Room nurses. The data were analysed with SPSS program. Result : In 57 nursing interventions, the 'Behavior' domain was the most frequently used. Core interventions of Operating Room were performed several times a day by more than 50% of Operating Room nurses. Core interventions of Operating Room were 16 Core interventions, 7 classes, 5 domains. In the core interventions, the 'Physiological:Complex' domain was the most frequently used. Core interventions of Operating Room were Surgical Preperation, Infection Control:Intraoperative, Surgical Precautions, Fall Prevention, Documentation, Surgical Assistance, Environmental Management:Safety, Skin Surveillance, Physical Restraint, Pressure Ulcer Prevention, Environmental Management:Comfort, Infection Protection, Presence, Emotional Support, Specimen Management, Shift Report. Conclusion : Core interventions of Operating Room have implications for nursing care practice, nursing education, nursing research, and nursing information system in Operating Room.

  • PDF

A Study on Optimal Electric Load distribution of Generators on board using a Dynamic Programming (동적계획법을 이용한 선내 발전시스템의 최적부하분담 방법에 관한 연구)

  • 유희한
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.106-112
    • /
    • 2000
  • Since the oil crisis, we have been concerned about the energy saving techniques of electric generating systems. As a part of the effort to save energy, automatic electric load sharing device was developed. Usually, ship's electric generating system consists of two or three sets of generator. And, electric generating system is operated as single or parallel operation mode according to the demanded electric power. Therefore, it is important to investigate generators operating mode for the supply of required electric power in the ship in order to decrease the operating cost. So, this paper suggests the method to solve the optimal electric load distribution problem by dynamic programming. And, this thesis indicates that the proposed method is superior to the lagrange multiplier's method in obtaining optimal load distribution solution in the ship's electric generating system.

  • PDF

Application of the Partial Discharge Measuring Method in Operating Transformer (운전중인 변압기의 부분방전 측정기법 적용)

  • 권동진;최인혁;정길조
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

A Study for Determining the Permissible Operating Range of Distributed Generation interconnected into Distribution System (배편계통에 도입되는 분산전원의 운전가능범위 결정에 관한 연구)

  • Kim, Tae-Eung;Kim, Jae-Eon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.93-101
    • /
    • 2002
  • This paper describes a new method for determining the permissible operating range of DG(Distributed Generation) when DG is introduced into power distribution systems of which the voltage is controlled by LDC(Line Drop Compensator). Much of the DG installed during the next millennium will be accomplished through the reconstruction of the electric power industry. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC. This paper presents a method for determining the permissible operating range of DG for proper voltage regulation of power distribution systems with LDC. Proposed method has been applied to a 22.9 kV model and practical distribution systems, and its result is almost identical with the simulation result.

The Statistical Analysis of Operating Life Characteristic on Poler Transformers(I) (전력용 변압기 운전수명 특성의 통계적 분석(I))

  • Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Kim, Moon-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1885-1887
    • /
    • 1996
  • Power transformers are the most important facilities in the substation of electrical power, yet they do not have the efficient operating life characteristics which are the important elements of repairing and maintenance in regional conditions. This paper describes the statistical analysis of operating conditions and troubles on transformers for the operating life assessment using Statistical Analysis System programs, Hazard method and Weibull distributions. We analyze transformers in several methods, and compares correlation relationship of operating life and troubles. Therefore, this study will be the useful basic operating life prediction technique of power transformers in the future.

  • PDF

A Simulation Method of PID Tuning with Process Modeling in Operating Nuclear Power Plants (가동원전에서 공정모델링을 통한 PID 튜닝 시뮬레이션 방법)

  • Min, Moon-Gi;Jung, Chang-Gyu;Lee, Kwang-Hyun;Lee, Jae-Ki;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.290-294
    • /
    • 2014
  • PID(Proportional, Integral, Derivative) controller is the most popular process controllers in nuclear power plants. The optimized parameter setting of the process controller contributes to the stable operation and the efficiency of the operating nuclear power plants. PID parameter setting is tuned when new process control systems are installed or current process control systems are changed. When the nuclear plant is shut down, a lot of PID tuning methods such as the Trial and Error method, Ultimate Oscillation method operation, Ziegler-Nichols method, frequency method are used to tune the PID values. But inadequate PID parameter setting can be the cause of the unstable process of the operating nuclear power plant. Therefore the results of PID parameter setting should be simulated, optimized and finally verified. This paper introduces the simulation method of PID tuning to optimize the PID parameter setting and confirms them of the actual PID controller in the operating nuclear power plants. The simulation method provides the accurate process modeling and optimized PID parameter setting of the multi-loop control process in particular.