• Title/Summary/Keyword: Operating mass flow rate

Search Result 200, Processing Time 0.024 seconds

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

Ignition Experiments of a High Pressure Liquid Propellant Thrust Chamber (실물형 연소기의 점화시험)

  • Moon Ilyoon;Kim SeungHan;Kim Jonggyu;Lim Byoungjik;Lee Kwangjin;Kim Intae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.265-268
    • /
    • 2005
  • A series of ignition tests had been conducted for a thrust chamber propelled by Jet A-1 and liquid oxygen with a chamber pressure of 52.5 bara and a thrust of 30 tonf. The chamber ignited by a hypergolic fluid, TEAL, keeps its first constant pressure low at $63\%$ of the design value by $61\%$ of a liquid oxygen mass flow rate and $67\%$ of fuel for 0.25 sec. The operating O/F ratio of the chamber was kept at lower values than that of the design operating condition throughout the whole ignition procedure. Surge of the chamber pressure is below $6\%$ of the design value.

  • PDF

Characteristics of Flank and Tip Seal Leakage in a Scroll Compressor for Air-Conditioners (공기조화기용 스크롤 압축기의 플랭크 및 팁실 누설특성)

  • Youn, Young;Kim, Yong-Chan;Min, Man-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.134-143
    • /
    • 2001
  • This paper presents the characteristics of flank and tip seal leakage in a scroll compressor for air-conditioners with R-22 under actual operating conditions. It is well known that the leakage has significant effect on the performance of the scroll compressor. Experiments were performed by using indirect method for measuring mass flow rate passing through flank and tip seal under actual operating conditions, In addition, an analytical model for tip seal leakage was developed to investigate tangential and radial leakage observed at grooves and contact points of tip seals. For low oil concentration, theoretical results were compared with experimental data to verify the analytical model. As a result, leakages through flank and tip seal parts were evaluated as afunction of pressure ratio, orbiting angle, discharge pressure, tip clearance, and leakage point. It was also found that the tip seal leakage was considerable even though the tip seal provided adequate sealing effect.

  • PDF

An Experimental Study on Heat Transfer Characteristics and Pressure Drop in Micro Plated Heat Exchangers with S-shape of Microchannel (S 형상의 마이크로 채널을 가진 마이크로 판형 열교환기의 열전달 특성 및 압력강하에 관한 실험적 연구)

  • Seo, Jang-Won;Kim, Yoon-Ho;Moon, Chung-Eun;Lee, Kyu-Jung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1876-1881
    • /
    • 2007
  • The micro plated heat exchangers were designed to transfer more heat/volume or mass than previous heat exchangers within the context of the design constraints specified. The increase of the surface-to-volume ratio results in an increase of the interfacial area. This enhances considerably the performance of a heat exchanger. This can be an important component in a wide range of applications fuel cell, aerospace, automotive, electronic system and home heating, etc). In this study, the performance evaluation of micro plated heat exchangers under the counter flows with straight and S-shaped channel are carried out. The pressure drop as well as inlet and outlet fluid temperature were measured at steady state under various operating conditions and the total heat transfer rate were also calculated.

  • PDF

Rotordynamci Effects Due to Aerodynamic Instability in a Turbo-compressor with Air Foil Bearings (공기 포일 베어링으로 지지되는 터보 압축기의 공력 불안정성이 로터에 미치는 진동 영향)

  • Kim, Tae-Ho;Lee, Yong-Bok;Kim, Chang-Ho;Kim, Kwang-Ho;Lee, Nam-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.191-198
    • /
    • 2002
  • Oil-free turbo-compressor supported by compliant foil bearings which remove oil-contamination by elimination of the conventional ball bearing and oil lubrication systems is presented. Turbo-compressor makes two individual air compression with two impellers at operating speed, 39,000rpm. In this study, the rotordynamic effects caused by aerodynamic instability were investigated with variable mass flow rate. Correlation between frequencies of pressure fluctuation in two diffusers and those of excitation forces on rotor were clearly developed in aerodynamic unsteady region. Thus, these results show that it is beneficial to design high speed rotating turbomachinery considering coupling effect between aerodynamic instability and rotordynamic force.

  • PDF

A Study on the Performance Analysis of Automotive Air Conditioning System (자동차용 에어컨 시스템의 성능해석에 관한 연구)

  • 이대웅;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.304-314
    • /
    • 2002
  • Performance analysis of the automotive air-conditioning system is conducted by using computer simulation, and performance tests are carried out by using the climate wind tunnel in order to verify simulation. Evaporator and condenser were modeled by using empirical correlation which was obtained from calorimeter data, and compressor was modeled by using map based method. The steady state thermodynamic conditions of refrigerant satisfying mass and energy balance were assumed in the simulation program for automotive airconditioning system. The system performance was analyzed by finite difference method until differential air enthalpy between evaporator inlet and outlet becomes converged. Simulation results are in good agreement with experimental results at most operating conditions. Variation of discharge temperature and pressure of compressor, outlet temperature of evaporator, cooling capacity, and COP were investigated in term of air volume flow rate for evaporator, compressor capacity, compressor speed, superheat of thermostatic expansion valve, and diameter of suction line.

A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22 (R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교)

  • Pak, H.Y.;Park, K.W.;Park, Y.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

Adsorption Characteristics of Volatile Organic Compounds-BTX on Activated Carbon Fiber (활성탄소섬유를 이용한 휘발성유기화합물 (VOCs-BTX)의 흡착특성)

  • 김한수;박영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.805-812
    • /
    • 1999
  • Adsorption characteristics of volatile organic compounds(VOCs) by activated carbon fiber(ACF) were investigated using a continuous system for benzene, toluene, xylene(BTX) generation. Studied characteristics for adsorption were equilibrium capacity, accumulative adsorption, and breakthrough curve. Operating variables were adsorption temperature(25~45$^{\circ}C$) and partial pressure(1.2~12 mmHg) of BTX. The experimental results show that the adsorption equilibrium capacity increases with increasing partial pressure of BTX and decreases with increasing temperature. It was also found that the break point was decreased with increasing partial pressure, temperature and gas flow rate due to an effect of mass transfer of adsorbate.

  • PDF

Study for the Cooling Performance Improvement of a Mini Bus (소형버스 냉각성능 향상 연구(I))

  • Lyu, Myung-Seok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.10-15
    • /
    • 2005
  • This study was initiated to evaluate the cooling performance of CAC (charged air cooler) and radiator in the engine room of a mini bus. So we had firstly to predict the mass flow rate coming from radiator grille and front bum per opening using computational fluid dynamics (CFD) simulation based on 3D configuration. And simulations were carried out for different cooling module layout and bum per opening hole size on sam e vehicle operating condition. Simulation results show that CAC cooling performance at reverse protecting plate-applying model was much efficient than that of the bum per opening hole size-increasing model in IMTD point of view. Part of the CFD simulation results was com pared to with experimental data. It was confirm ed that the CFD approach using STAR-CD based on pursuing no-com promise solution could provide design engineers with useful design information in the early design stage of vehicle development.

Analysis of Decompression Control Characteristics of Pneumatic Pressure Control System Considering Heat Transfer Characteristics (열전달 특성을 고려한 공기압 압력제어계의 감압제어특성 해석)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2006
  • Pneumatic control systems have been mainly used as a high speed operating system. Therefore, state change of air in a control volume was assumed to be adiabatic change and, pneumatic control systems have been analyzed by using this assumption. Especially, when absolute value of pressure change in the control volume is small, there is a tendency to neglect effect of temperature change on pneumatic control system because temperature change owing to pressure change is small. In this study, an effect of temperature change of air on the decompression control process was analyzed by considering change of mass flow rate, and heat transfer characteristics between air in the chamber and the chamber wall. As a result, this study could confirm that a slight temperature change of the air in the pneumatic pressure control system can influence on the dynamic characteristics of pressure response, and pressure control performance.

  • PDF