• Title/Summary/Keyword: Operating margin

Search Result 298, Processing Time 0.026 seconds

An Interior Point Method based Reactive Optimal Power Flow Incorporating Margin Enhancement Constraints

  • Song Hwa-Chang;Lee Byong-Jun;Moon Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.152-158
    • /
    • 2005
  • This paper describes a reactive optimal power flow incorporating margin enhancement constraints. Margin sensitivity at a steady-state voltage instability point is calculated using invariant space parametric sensitivity, and it can provide valuable information for selection of effective control parameters. However, the weakest buses in neighboring regions have high margin sensitivities within a certain range. Hence, the control determination using only the sensitivity information might cause violation of operational limits of the base operating point, at which the control is applied to enhance voltage stability margin in the direction of parameter increase. This paper applies an interior point method (IPM) to solve the optimal power flow formulation with the margin enhancement constraints, and shunt capacitances are mainly considered as control variables. In addition, nonlinearity of margin enhancement with respect to control of shunt capacitance is considered for speed-up control determination in the numerical example using the IEEE 118-bus test system.

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

Influence of Parasitic Resistances and Transistor Asymmetries on Read Operation of High-Resistor SRAM Cells (기생저항 및 트랜지스터 비대칭이 고저항 SRAM 셀의 읽기동작에 미치는 영향)

  • Choi, Jin-Young;Choi, Won-Sang
    • Journal of IKEEE
    • /
    • v.1 no.1 s.1
    • /
    • pp.11-18
    • /
    • 1997
  • By utilizing the technique to monitor the DC cell node voltages through circuit simulation, degradation of the static read operating margin In high load-resistor SRAM cell was examined, which is caused by parasitic resistances and transistor asymmetries in this cell structure. By selectively adding the parasitic resistances to an ideal cell, the influence of each parasitic resistance on the operating margin was examined, and then the cases with parasitic resistances in pairs were also examined. By selectively changing the channel width of cell transistors to generate cell asymmetry, the influence of cell asymmetry on the operating margin was also examined. Analyses on the operating margins were performed by comparing the supply voltage values at which two cell node voltages merge to a single value and the differences of cell node voltages at VDD=5V in the simulated node voltage characteristics. By determining the parasitic resistances and the transistor asymmetries which give the most serious effect on the static read-operation of SRAM cell from this analysis based on circuit simulated, a criteria was provided, which can be referred in the design of new SRAM cell structures.

  • PDF

The Optimal Operating Points of Multiple UPFCs for Enhancing Power System Security Level (전력시스템 안전도 향상을 위한 다기 UPFC의 최적 운전점 결정)

  • 임정욱;문승일
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.8
    • /
    • pp.388-394
    • /
    • 2001
  • This paper presents how to determine the optimal operating points of Unified Power Flow controllers (UPFC) the line flow control of which can enhance system security level. In order to analyze the effect of these devices on the power system, the decoupled model has been employed as a mathematical model of UPFC for power flow analysis. The security index that indicates the level of congestion of transmission line has been proposed and minimized by iterative method. The sensitivity of objective function for control variables of and UPFC has been derived, and it represents the change in the security index for a given set of changes in real power outputs of UPFC. The proposed algorithm with sensitivity analysis gives the optimal set of operating points of multiple UPECs that reduces the index or increases the security margin and Marquart method has been adopted as an optimization method because of stable convergence. The algorithm is verified by the 10-unit 39-bus New England system that includes multiple FACTS devices. The simulation results show that the power flow congestion can be relieved in normal state and the security margin can be guaranteed even in a fault condition by the cooperative operation of multiple UPECs.

  • PDF

The Optimal VAR Planning Considering Voltage Stability Margin (전압안정도여유를 고려한 무효전력원 배분계획)

  • Song, Kil-Yeong;Choi, Sang-Kyu;NamKung, Jae-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.33-35
    • /
    • 1993
  • This paper presents a new optimal VAR planning algorithm considering voltage stability margin. The characteristic of this method is to make it possible to formulate VAR planning for the dual purpose of maintaining voltage profiles within specified limits, and increasing the voltage stability margin of anticipated operating conditions with respect to voltage collapse. The IEEE-30 bus system is used to demonstrate the capability of the proposed algorithm.

  • PDF

A Study of Financial Performance using DuPont Analysis in Food Distribution Market

  • Kim, Hak-Seon
    • Culinary science and hospitality research
    • /
    • v.22 no.6
    • /
    • pp.52-60
    • /
    • 2016
  • This study attempts to measure the financial performance of the food distribution company. In order to achieve the goal, this study have measured the ratios of ROE, ROA applying the DuPont analysis, which have been demonstrated with tables to show the change periodically. DuPont analysis is based on analysis of Return on Equity (ROE) & Return on Investment (ROI). The return on equity disaggregate performance into three components: Net Profit Margin, Total Asset Turnover, and the Equity Multiplier. The return on investment consists of Assets Turnover (Operating Income${\times}$Total Assets) and Profit Margin (EBIT${\times}$Operating Income). From the study it if found that Hyundae Green Food's Financial performance is high followed by Foodmerce and then Dongwon home food and Lotte Food. The four companies are significant at their level. In conclusion, ROE & ROI is the most comprehensive measure of profitability of a firm. It considers the operating and investing decisions can be made as well as the financing and their leverage-related decisions.

Numerical Investigation of Ring Groove Effect in a Centrifugal Compressor (원심압축기의 링 그루브 효과에 관한 수치해석적 연구)

  • Park, Chi-Yong;Choi, Young-Seok;Lee, Kyoung-Yong;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.11-16
    • /
    • 2011
  • This paper presents a numerical study of casing treatments on a centrifugal compressor stage to improve stability and the surge margin. High efficiency, a high pressure ratio, and a wide operating range are required for a high performance centrifugal compressor. In the present study, a ring groove arrangement was applied to the transonic centrifugal compressor. According to the numerical analysis using a commercial code ANSYS-CFX, the unstable phenomena limiting the range of the centrifugal compressors were compared with and without a ring groove. Although the ring groove decreased the efficiency, but increased the operating range by suppressing a flow separation at the leading-edge of the impeller especially near shroud part. Newly designed ring groove arrangement improved the compressor performance and increased the operating range of the compressor.

Comparison between Korean Regional Public Hospitals and Private non-profit General Hospitals for Investment Efficiency and Management Performance (지방공사의료원과 민간 종합병원 간의 투자효율 및 경영성과 비교)

  • Ha, Au-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.523-529
    • /
    • 2017
  • This study analyzed the financial information between 2011 and 2014 comparing management performance and utilization of capital and human resources between private non-profit general hospitals and regional public hospitals operated as general hospitals. The purpose of this study was to enhance the productivity for financial independence of regional public hospitals. Comparison analysis variables were value added to the total assets, value added to the productive activity tangible fixed assets, value added to personnel expenses, ratio of value added, and operating margin to revenues. According to the analysis results, regional public hospitals showed lower investment efficiency indicator and higher ratio of value added, as well as significantly lower operating margin-to-revenues compared with private non-profit general hospitals. Moreover, the effect of investment efficiency indicators on operating margin-to-revenues was value added to the productive activity of tangible fixed assets and value added to personnel expenses in regional public hospitals; the value added to personnel expenses in private non-profit general hospitals had a significant effect on the operating margin-to-revenues, the effect of value added to personnel expenses was the greatest. Therefore, it is necessary to asset utilization to the revenue and propriety of human resources to personnel expenses in regional public hospitals.

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

A Procedure for Statistical Thermal Margin Analysis Using Response Surface Method and Monte Carlo Technique (반응 표면 및 Monte Carlo 방법을 이용한 통계적 열여유도 분석 방법)

  • Hyun Koon Kim;Young Whan Lee;Tae Woon Kim;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.38-47
    • /
    • 1986
  • A statistical procedure, which uses response surface method and Monte Carlo simulation technique, is proposed for analyzing the thermal margin of light water reactor core. The statistical thermal margin analysis method performs the best.estimate thermal margin evaluation by the probabilistic treatment of uncertainties of input parameters. This methodology is applied to KNU-1 core thermal margin analysis under the steady state nominal operating condition. Also discussed are the comparisons with conventional deterministic method and Improved Thermal Design Procedure of Westinghouse. It is deduced from this study that the response surface method is useful for performing the statistical thermal margin analysis and that thermal margin improvement is assured through this procedure.

  • PDF