• Title/Summary/Keyword: Operating limit

Search Result 518, Processing Time 0.03 seconds

A Study on Strengthening Option of T-N Effluent Water Quality Standards of Sewage Treatment Plants (하수처리시설의 T-N 방류수 수질기준 강화방안에 관한 연구)

  • Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.216-225
    • /
    • 2018
  • Over the past 40 years, the public sector has continued to invest in the sewage treatment plants (STPs) in Korea. Currently, the domestic sewage treatment rate is over 90% with the enhancement of operating efficiency of the STPs, and water quality of major rivers has been continuously improved. However, COD and T-N indicators are stagnating or slightly worsening, and though advanced treatment facilities are installed in most of the STPs, there is a limit to the removal of nutrients. Since there are a lot of water pollution sources in the vicinity of the watershed because of high population density in Korea, it is essential to reduce the inflow of the nutrients in order to prevent the eutrophication of the rivers and lakes. While the effluent T-P standard in STPs has greatly strengthened since 2012, which results in the considerable investment for the improvement of treatment process in STPs for the last few years, it is necessary to strengthen the T-N standards, as the effluent standard of T-N has been maintained at 20 mg/L since 2002. In this study, based on the analysis of the effluent T-N standard status of major industrialized countries, and the domestic nitrogen load in public waters, the option of appropriate T-N standard level is reviewed, and the required investment costs and the effect of strengthening the standard are estimated.

Development of a Scrubber Wastewater Cleaning System to Improve Odor Removal Efficiency (악취저감 향상을 위한 스크러버 세정수 처리 시스템 개발연구)

  • Chung, Gu-Hoi;Im, Moon-Soon;Kim, Youn-Soo;Kim, Duk-Hyun
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.34-41
    • /
    • 2017
  • The scrubber wastewater should be replaced frequently to maintain efficiency. Most chemical companies consign scrubber wastewater, because there are no wastewater treatment facilities. So scrubber wastewater is not frequently replaced because of high treatment cost. For this reason, the most scrubber exhaust gas exceeds the odor emission limit or has a phenomenon that the odor intensity of exhaust gas becomes higher. Therefore we have developed a scrubber wastewater cleaning system consisting of filtration and adsorption processes. The scrubber wastewater cleaning system was applied two chemical companies. We evaluated the water quality and odor reduction effect before and after system application. As a result, scrubber wastewater quality improved by 50% or more, odor reduction efficiency of scrubber exhaust gas improved by 20% or more. And the total operating costs of the scrubber could be reduced by 40% or more.

Design of Invisible Watermarking for H.264/AVC Video Protection (H.264/AVC 비디오 보호를 위한 비가시적 워터마킹의 설계 및 검증)

  • Park, Hye-Jeong;Choi, Jun-Rim
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.74-79
    • /
    • 2008
  • In this paper, we propose and design a new 0.264/AVC watermarking algorithm for protection of copyright by inserting a watermark after quantization. This invisible watermarking algorithm insets a watermark into chrominance components of I frame such that we can avoid degradation of original images. According to test results we could limit image degradation by 1dB, avoid bit rate increment within 2% and increase processing time by only 2%. The IP is designed by Hynix 0.25 micron technology and the maximum operating frequency of 115MHz is achieved. The PSNR of the embedded watermark is about 35dB according to the test result.

Identification of Pick up Sound for Laser printers Based on Psychoacoustic Parameters (심리음향의 음질요소를 이용한 레이저 프린터 급지 이음 평가 및 부품 조합 최적화)

  • Lee, Young-Jun;Shin, Tae-Jin;You, Jin;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.853-860
    • /
    • 2012
  • This paper identifies a cause of pick up noise in a laser printer and a relationship between pick up noise and major components related to pick up noise. A pick up sound is affected by many components such as spring force, spring constant, and friction coefficient. Objective evaluation for the pick up sound is difficult because of back ground sound such as operating sound. Especially, a sound between a friction pad and a paper in the process of printing has become an essential issue in an aspect of quality evaluation. However the existing criteria for determining the above sound have solely relied on human's subjective judgments; which highlights the requirement to objectify these criteria. In this paper, the standard of existing pick up noise is established by finding the tonality, which is a psychoacoustic parameter, of noticeable limit sound level. Based on the findings of the method, the study has found factors which cause pick up noise and suggests the substitution of following components of printers such as spring constants, spring force, and the quality of friction pads. As a result, it is confirmed that the proposed pick up noise index has usefulness to classify whether existence of pick up noise with an objective evaluation and not to occur the noise based on design optimized combination of laser printer components.

Validation of Serum Aminotransferases Levels to Define Severe Dengue Fever in Children

  • Srivastava, Geetika;Chhavi, Nanda;Goel, Amit
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.4
    • /
    • pp.289-296
    • /
    • 2018
  • Purpose: We aimed to study the pattern of liver-injury in children with dengue fever (DF) and validate serum aminotransferase ${\geq}1,000IU/L$ as a marker of severe DF. Methods: Children admitted with DF were included. DF was defined by presence of clinical criteria and positive serological or antigen tests in absence of other etiology. DF severity was graded as dengue without or with warning signs and severe dengue. Liver-injury was defined as alanine aminotransferase (ALT) more than twice the upper limit of normal (boys, 30 IU/L; girls, 21 IU/L). Results: Of 372 children with DF, 144 (38.7%) had liver-injury. Risk of liver-injury and aminotransferase levels increased with DF severity (p<0.001). Recommended ALT and aspartate aminotransferase (AST) cut-off at ${\geq}1,000IU/L$ had sensitivity 4.8% (5/105), specificity 99.3% (265/267) for detection of severe DF. In children with ALT and AST <1,000 IU/L (n=365), the area under receiver operating curves for prediction for severe DF, were 0.651 (95% confidence interval [CI], 0.588-0.714; p<0.001) for ALT and 0.647 (95% CI, 0.582-0.712; p<0.001) for AST. Serum ALT at 376 IU/L and AST at 635 IU/L had sensitivity and specificity comparable to ${\geq}1,000IU/L$ for defining severe DF. Conclusion: Liver-injury is common in DF. The ALT and AST levels increase with DF severity. ALT and AST levels of ${\geq}1,000IU/L$ could be lowered to 376 IU/L and 635 IU/L respectively for defining severe DF.

Prehospital Care of 119 EMT for Non-traumatic Cardiac Arrest and Improvement to Increase Advanced Care Rate (119 구급대원의 비외상성 심정지 환자의 병원전 처치실태 및 전문 처치율 향상을 위한 개선 방안)

  • Lee, Kyoung-Youl;Yun, Seong-Woo
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.21-31
    • /
    • 2011
  • This study aimed at evaluating and developing 119 emergency medical technicians' prehospital care for non-traumatic cardiac arrest. Total 322 EMT in Chungnam province and Daejeon city filled out the self-administered questionnaire. The data were analyzed by SPSS 18.0 for descriptive statistics. Among the 322 EMT, 309 (97%) and 169(53%) always or almost performed CPR and AED for nontraumatic cardiac arrest patient, respectively. Among the advanced EMT and nurse, IV were sometimes or not performed at 94.7% and medication including epinephrine which commonly used for survival of cardiac arrest were treated just at 9.3 % (14 person). The reason they did not perform each procedure for airway management, AED or IV was lack of manpower, limit of time or joggle of ambulance and legal restrictions. In conclusion, to increase survival rate of non-traumatic cardiac arrest in out-of-hospital, it is necessary to increase manpower, legal protection of EMS, establishment of standard operating procedure, practice for improvement technique and use of medication for ACLS.

Application of Cubic Spline Synthesis in On-Line Core Axial Power Distribution Monitoring (실시간 노심출력분포 측정을 위한 3차 SPLINE합성법의 응용)

  • In, Wang-Kee;Yoo, Hyung-Keun;Auh, Geun-Sun;Lee, Chong-Chul;Kim, Si-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.316-320
    • /
    • 1991
  • The Core Operating Limit Supervisory System (COLSS) is digital computer based on-line monitoring system that is designed to assist the operator in monitoring of the Limiting Conditions for Operation. A current COLSS calculates axial power distribution based on in-core detector signals using 5th order Fourier series method. It was found that the 5th elder Fourier series method was not accurate for certain axial power shapes, especially saddle power shapes, resulting in thermal margin decrease. A cubic spline synthesis was applied to the COLSS in order to improve the axial power distribution monitoring for the various axial power shapes. The results showed that the cubic spline synthesis simulated more accurately the axial power shapes, up to 5% in RMS errors, compared to those of the Fourier series.

  • PDF

경기도 일죽지역 천부지하수의 질산성 질소 오염특성

  • 김연태;신우식;우남칠;이상모
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.215-218
    • /
    • 2002
  • The purposes of this research are to identify the source and the extent of contamination of nitrate in groundwater in a typical agricultural area. The study area has many livestock raising facilities, rice paddies and grape farms. In order to identify the hydrogeological character, we sampled groundwater and surface water in 27 locations and performed chemical analyses. Nitrate-nitrogen is the major contaminant in this area. Approximately 32 ~ 42% of groundwater samples are over the drinking water limit(10 mg/L) and 77% estimated to be entered from artificial sources. The nitrogen isotope analysis indicates animal waste being the major source of nitrate in water samples. Not only presently operating livestock facilities but also abandoned ones influence groundwater quality for a long time.

  • PDF

A Study on the Design and Validation of Automatic Pitch Rocker for the Aircraft Deep Stall Recovery (항공기의 실속 회복을 위한 자동 회복 장치 설계 및 검증에 관한 연구)

  • Hahn, Seong-Ho;Hwang, Byung-Moon;Lee, Young-Ho;Lee, Dong-Kyu;Ahn, Sung-Jun;Kim, Chong-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • Modem version of supersonic jet fighter aircraft must have been guaranteed appropriate controllability and stability in HAoA(High Angle of Attack). Limit value of aircraft entering into the departure in HAoA is related to aircraft configuration design. But, the control law such as AoA and yaw-rate limiter is implemented in digital Fly-By-Wire flight control system of supersonic jet fighter to guarantee the aircraft's safety in HAoA. The HAoA flight control law have two parts, one is control law of departure prevention and the other is control law of departure recovery support. The control laws of departure prevention for advanced jet trainer consist AoA limiter, roll command limiter and rudder fader. The control laws of departure recovery support are consist yaw-rate limiter and MPO(Manual Pitch Override) mode. The guideline of pitch rocking using MPO mode is simple, but operating skill of pitch rocking is very difficult by the pilot with inexperience of departure situation. This paper addresses the design and validation of APR(Automatic Pitch Rocker) control law instead of MPO in order to automatic recovery without manual pitch rocking by the pilot. And, recovery characteristic with APR verifies by the nonlinear analysis and pilot evaluation.

Electro-fatigue Characteristic of Shape Memory Alloy Applied to the Electrosurgical Knee Wand of Variation of Wand Head Angle in Electrosurgical Knee Surgeries (헤드각이 변화하는 Electrosurgical Knee Wand에 적용된 형상기억합금 스프링의 전기적 피로특성)

  • An, Jae-Uk;Kim, Cheol-Woong;Lee, Ho-Sang;Wang, Joon-Ho;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1547-1552
    • /
    • 2008
  • The tip of these catheter with straight needles is not able to reach in the vicinity of the disc bulging, which are the cause of the low back pain and because the far indirect radio-frequency treatment results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body catheter device. To increase the possibility of nucleoplasty, the needle tip should be located at the closest area of the lesion. For this reason, the best way to increase the success rate of the operation is that the needle tip should access 3-dimensionally to the operating field as soon as possible. To achieve this aim, our studies are restricted as follows: 1) the SMA catheter design to control the 3-dimensional direction, 2) the security of the immediate response by the positive control of the SMA element thermal distribution using Peltier thermoelectric elements, 3) the aquisition of the control data by monitoring the relationship between the temperature of SMA element and the displacement, and 4) the design of the controller to guarantee the accurate location.

  • PDF