• Title/Summary/Keyword: Operating environment

Search Result 2,892, Processing Time 0.033 seconds

A Study on the Accuracy Enhancement Using the Direction Finding Process Improvement of Ground-Based Electronic Warfare System (지상용 전자전장비의 방향 탐지 프로세스 개선을 통한 정확도 향상에 관한 연구)

  • Chin, Huicheol;Kim, Seung-Woo;Choi, Jae-In;Lee, Jae-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.627-635
    • /
    • 2017
  • Modern warfare is gradually changing into a network war, and information electronic warfare is also progressing. In modern war, electronic warfare is all military activity concerned with electromagnetic field use, such as signal collecting, communication monitoring, information analysis, and electronic attack. The one key function of signal collecting for enemy signal analysis, direction finding, collects the signal radiated from enemy area and then calculates the enemy direction. This paper examined the Watson-Watt algorithm for an amplitude direction finding system and CVDF algorithm for phase direction finding system and analyzed the difference in the direction finding accuracy between in the clean electromagnetic field environment and in the real operating field environment of electronic warfare system. In the real field, the direction finding accuracy was affected by the reflected field from the surrounding obstacles. Therefore, this paper proposesan enhanced direction finding process for reducing the effect. The result of direction finding by applying the proposed process was enhanced above $1.24^{\circ}$ compared to the result for the existing process.

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Analysis of Performance Requirements of Mechanical System for Recovery of Deposited Hazardous and Noxious Substances from Seabed around Seaport (항만 해저침적 위험유해물질(HNS) 회수용 기계장치의 성능요건 분석)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.681-688
    • /
    • 2020
  • Approximately 6,000 chemicals are transported through the sea, including hazardous and noxious substances (HNS), which cause marine pollution and are harmful to marine life. The HNS discharged into the sea during the maritime transportation process undergoes physical and chemical changes on the sea surface and in seawater, and some types of HNS sink and are deposited on the seabed. The HNS deposited on the seabed adversely affects the benthic ecosystem, and hence, it is desirable to detect, treat, and recover the HNS on the seabed. Therefore, this study was conducted to analyze the performance requirements that should be considered as the top priority when developing a mechanical system for recovering the HNS deposited on the seabed. Various types of existing dredging devices used for collecting and recovering pollutants from river beds and seabeds were investigated, and 10 performance indices for the mechanical devices were selected. The new performance requirements for the development of the seabed-deposited HNS recovery system were proposed using performance indices. By considering the depth of water in domestic seaports, some of the performance requirements of the mechanical system for recovering deposited HNS from the seabed were obtained as follows: production rate (50-300 ㎥/hr), maximum operation depth (50 m), sediment type (most forms), percentage of solids (10 % or higher), horizontal operating accuracy (±10 cm), limiting currents (3-5 knots). These performance requirements are expected to be useful in the conceptual and basic design of mechanical systems for recovering seabed-deposited HNS.

Fermentative Hydrogen Production under Various $SO_4^{2-}$ Concentration using Anaerobic Mixed Microflora (혐기 혼합균주에서 황산염 농도변화에 따른 수소 발효 특성)

  • Hwang, Jae-Hoon;Choi, Jeong-A;Lee, Jong-Hak;Jeong, Tae-Young;Cha, Gi-Cheol;Song, Ho-Cheol;Yong, Bo-Young;Kim, Dong-Jin;Jeon, Byong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.434-441
    • /
    • 2009
  • The effect of varying sulfate concentration on continuous fermentative hydrogen production was studied using enriched mixed microflora in continuously fed reactor. Glucose was used as a model substrate for carbohydrates, and hydraulic retention time (HRT) was maintained at 1, 0.5, 0.25 day, respectively. Sulfate concentration was 0${\sim}$20,000 mg/L and the operating pH was maintained at 5.5. The experimental results indicate that hydrogen production is not affected by high sulfate concentration and shorter HRT of 0.25 day enhance hydrogen production. At HRT 1, 0.5, 0.25 day, the hydrogen production rate and hydrogen yield were 2.6, 4.6, 9.4 L/day, and 2.0, 1.8, 1.6 mol $H_2$/mol glucose, respectively. Residual sulfate content was 96${\sim}$98, 95${\sim}$97, and 94${\sim}$97% at HRT 1, 0.5, 0.25 day which show that no sulfate reduction occurred in the reactor during the experiments. Results of Fluorescence In Situ Hybridization (FISH) may indicate the presence of HPB (hydrogen producing bacteria) under all experimental conditions. However, SRB (sulfate reducing bacteria) were not found.

Argo Project: On the Distribution Prediction of Drifting Argo Floats (Argo프로젝트: Argo플로트 분포 예측)

  • Yang Chan-Su;Ishida Akio
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.1
    • /
    • pp.22-29
    • /
    • 2004
  • An international project, known as Argo, for collecting data on temperature, salinity and velocity of currents in the world's oceans, has been started in the year 2000 and the full Argo array of approximately 3000 floats will be deployed by 2006. 18 countries deployed 1,023 floats, which are operating in the ocean of the world as of December 2003. In the present study, we tried to predict float distribution and a rate of drifting ashore of the floats after their termination based upon a product of the ocean general circulation model of JAMSTEC (Japan Marine Science and Technology Center). We first evaluated reliability of the model prodilct quantitatively by comparing trajectories of surface buoys of WOCE Surface Velocity Program (SVP) and those predicted by the model surface current field. It is found that the model is acceptable for practical application to deploy floats and to estimate those trajectories. 653 particles at 3-degree spacing are used to investigate the ratio of floats drifted ashore, given that during the first 4 years floats cycle between the surface and 2000m for 10 days and then floats are on just the surface for 100 years. The simulation indicates that about 29% of deployed floats will be drifted ashore within 100-year.

  • PDF

An Automatic Transfer System of the Path for an Unmanned Machine in the Greenhouse (온실내 무인작업기를 위한 경로 자동변환 시스템 개발)

  • 김창수;이대원;이승기
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.237-243
    • /
    • 2000
  • Agricultural machine is currently operated by man power in the greenhouse, which is oppressively hot and humid, and is for a farmer not to work in comfortable circumstances. In the future, agricultural machine will not have to operate by man power, but it will need do by unmanned power. In order to put into the automatic and unmanned operation of agricultural machine, this system was designed and built to move through the fixed path in the greenhouse. This system was composed of guiders(wires), a limit switch, an operating equipment, its software for automatizing a machine in the greenhouse. The guider was connected between the wall pillars, and the equipment was able to slide over the fixed path made of the guider, by rectilinear and rotational motion. A micro mouse was developed with a stepping motor to calculate on the success rate of its operation with the system As might be expected, this system with the micro mouse was moved the moved the paths with a success rate of 100% on the flat plane surface in our laboratory. However, on the sand plane or the other materials plane, the success rate was not better than 80%. If the micro mouse were well operated, the success rate was would be 100%. Based on the results of this research, this system would be expected to operate well on the path made of a simple wire.

  • PDF

Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle (고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발)

  • Hwang, A-Rom;Ahn, Nam-Hyun;Yoon, Seon-Il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.666-673
    • /
    • 2013
  • This paper proposes the performance evaluation test of attitude heading reference system (AHRS) suitable for small high speed autonomous underwater vehicle(AUV). Although IMU can provides the detail attitude information, it is sometime not suitable for small AUV with short operation time in view of price and the electrical power consumption. One of alternative for tactical grade IMU is the AHRS based micro-machined electro mechanical system(MEMS) which can overcome many problems that have inhibited the adoption of inertial system for small AUV such as cost and power consumption. A cost effective and small size AHRS which incorporates measurements from 3-axis MEMS gyroscopes, accelerometers, and 3-axis magnetometers has been developed to provide a complete attitude solution for AUV and the attitude calculation algorithm is derived based the coordinate transform equation and Kalman filter. The developed AHRS was validated through various performance tests as like the magnetometer calibration, operating experiments using land mobile vehicle and flight motion simulator (FMS). The test of magnetometer calibration shows the developed MEMS AHRS is robust to the external magent field change and the test with land vehicle proves the leveling error of developed MEMS AHRS is below $0.5^{\circ}/hr$. The results of FMS test shows the fact that AHRS provides the measurement with $0.5^{\circ}/hr$ error during 5 minutes operation time. These results of performance evaluation tests showed that the developed AHRS provides attitude information which error of roll and pitch are below $1^{\circ}$ and the error of yaw is below $5^{\circ}$ and satisfies the required specification. It is expected that developed AHRS can provide the precise attitude measurement under sea trial with real AUV.

Database Development for Equipment Performance Monitoring System in an Offshore Plant (해양플랜트 장비 성능 모니터링 시스템을 위한 데이터베이스 설계)

  • Yoo, Seung-Yeol;Seo, Ju-Wan;Lee, Jae-Chul;Hwang, Se-Yun;Hwang, Ho-Jin;Lee, Soon-Sup
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.474-482
    • /
    • 2020
  • To ensure the safe operation of offshore plants, a system is needed for evaluating the equipment performance and for monitoring the results. Currently, owing to the operating environments of of shore plants situated far from the land, measurement data must be periodically stored in storage devices and carried on the land for evaluating the equipment performance. Consequently, it is difficult to prevent equipment failure because the performance evaluation cycle is long. Furthermore, until the next performance evaluation is conducted, it is difficult to determine the equipment's degree of performance degradation. Hence, it is necessary to install an onboard equipment performance monitoring system within the offshore plant. In this study, to evaluate and visualize the results of equipment performance within an offshore plant, a database was designed as the initial step towards the development of an equipment performance monitoring system. The tag data of major equipment were selected and analyzed. Furthermore, in order to store and manage the data measured in real time within the offshore plant, a database was developed for the onboard equipment performance monitoring system.

A Study on the Unmanned convenience Store Operation System from the Viewpoint of Visual Merchandising (비주얼 머천다이징 관점에서의 무인 편의점 운영시스템에 관한 연구)

  • Seo, Jung-Hwa;Yang, Hoe-Chang;Park, Chul-Ju;Youn, Myoung-Kil
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.12
    • /
    • pp.45-53
    • /
    • 2018
  • Purpose - The purpose of the study was to investigate operation system of current convenience store and competing retail store and to find out development of unattended convenience store. Operators can save labor cost and solve labor seeking when opening shop under suitable environment and commerce area, and assure of employee's safety. Customers are allowed to select commodity comfortably without disclosure of face and to shorten standby time at simple store opening, buying and paying and to produce convenient living environment by financing, delivery and goods control. This study examined effect and problems of operation of existing and unattended convenience store from point of view of visual merchandising to find out model of unattended convenience store and to strengthen competitiveness of convenience store business. Research design, data, and methodology - Research procedure of accomplishment of goal of the study was: The study investigated state of distribution business, and role and definition of VMD. First, VMD played an important role of promotion and competitiveness of unattended convenience stores. Second, the author investigated research and cases of unattended convenience stores 14 months, that is to say, from August 15, 2017 to October 15, 2018. Third, the author investigated on-the-spot three of common convenience stores, three of unattended convenience stores and three of retailers one month, that is to say, June 1, 2018 to July 1, 2018. The subject was convenience stores and retailers selling similar type of products at Seoul and metropolitan area. Results - Layout, selling place, brand identity, goods assortment, authentication system, product information cognition and control, buying and payment system, security system, salesmen, promotion and other services should be improved from point of view of merchandising. Structure, furniture, lighting, voice, façade, VP, PP, IP and POP should be developed. Conclusions - Unattended convenience stores saved operating cost and lessened labor and gave visitors convenience and comfortable shopping and made use of resources effectively. Further studies with quantitative analysis shall find out strategic conditions for promotion of unattended convenience stores.

Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5 (PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구)

  • Lee, Yong Hwan;Park, Jin Su;Oh, Jun;Choi, Jin Soo;Kim, Hyun Jae;Ahn, Joon Young;Hong, You Deog;Hong, Ji Hyung;Han, Jin Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.