• Title/Summary/Keyword: Operating control system

Search Result 3,099, Processing Time 0.169 seconds

An Efficient TCP Buffer Tuning Algorithm based on Packet Loss Ratio(TBT-PLR) (패킷 손실률에 기반한 효율적인 TCP Buffer Tuning 알고리즘)

  • Yoo Gi-Chul;Kim Dong-kyun
    • The KIPS Transactions:PartC
    • /
    • v.12C no.1 s.97
    • /
    • pp.121-128
    • /
    • 2005
  • Tho existing TCP(Transmission Control Protocol) is known to be unsuitable for a network with the characteristics of high RDP(Bandwidth-Delay Product) because of the fixed small or large buffer size at the TCP sender and receiver. Thus, some trial cases of adjusting the buffer sizes automatically with respect to network condition have been proposed to improve the end-to-end TCP throughput. ATBT(Automatic TCP fluffer Tuning) attempts to assure the buffer size of TCP sender according to its current congestion window size but the ATBT assumes that the buffer size of TCP receiver is maximum value that operating system defines. In DRS(Dynamic Right Sizing), by estimating the TCP arrival data of two times the amount TCP data received previously, the TCP receiver simply reserves the buffer size for the next arrival, accordingly. However, we do not need to reserve exactly two times of buffer size because of the possibility of TCP segment loss. We propose an efficient TCP buffer tuning technique(called TBT-PLR: TCP buffer tuning algorithm based on packet loss ratio) since we adopt the ATBT mechanism and the TBT-PLR mechanism for the TCP sender and the TCP receiver, respectively. For the purpose of testing the actual TCP performance, we implemented our TBT-PLR by modifying the linux kernel version 2.4.18 and evaluated the TCP performance by comparing TBT-PLR with the TCP schemes of the fixed buffer size. As a result, more balanced usage among TCP connections was obtained.

Sharing of DLNA Media Contents among Inter-homes based on DHCP or Private IP using Homeserver (동적 사설 IP 기반의 다중 홈간 DLNA 미디어 컨텐츠 공유)

  • Oh, Yeon-Joo;Lee, Hoon-Ki;Kim, Jung-Tae;Paik, Eui-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.13C no.6 s.109
    • /
    • pp.709-716
    • /
    • 2006
  • According to the increase of various AV media devices and contents in the digital home, the DLNA becomes to play an important role as the interoperability standard between then Since this guideline only focuses on the interoperability among home networked devices, media players, and media contents existing inside of the homenetwork, there is no retrieval and transmission method for sharing multimedia contents located over several homes via Internet. Additionally, this guideline lets device-detection and notification messages to be transmitted using W multicast methods, and current Internet environment cannot guarantee consistent IP multicast services, it has the limitation that it cannot retrieve and control DLNA devices in other digital homes remotely via the Internet. Therefore, in this paper, we propose the IHM(Inter-Home Media) proxy system and its operating mechanism to provide a way of sharing media contents distributed over multiple DLNA-based homes, through analyzing these limitations and building up a sharing method for A/V media contents distributed over the DLNA homes based on the dynamic or private IP networks. Our method removes the limitation on the user locations through sharing distributed media contents, and also makes cost-downs for storing media contents, from the view point of individual residents.

A Reduction in Pressure Ripples of Axial Piston Pumps of Bent Axis by Phase Interface (위상간섭을 이용한 사축식 액셜 피스톤 펌프의 압력 맥동 감소)

  • Kim, Kyung-Hoon;Park, Kyung-Seok;Jang, Ju-Sub;Kim, Bong-Hwan; Lee, Kyu-Won;Son, Kwon;Shin, Min-Ho
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1261-1265
    • /
    • 2003
  • Axial piston pumps of bent axis have been commonly used in hydraulic systems because of high pressure level. best efficiency, low shear force on pistons and low operating costs. The other side, they have a few demerits like that they have the relatively high number of moving parts and more discharge pressure ripples. Especially, the discharge pressure ripples bring about vibrations and noises in hydraulic system components such as connecting pipes and control valves, so that these deteriorate the stability and accuracy of the systems. Therefore, the hydraulic systems having the axial piston pumps of bent axis require the methods to reduce the discharge pressure ripples. So, the purpose of this paper is to reduce the discharge pressure ripples by the phase interference of pressure wave and to develope the analysis model of the pumps to predict the discharge pressure ripples. In this paper, the analysis model of the axial piston pumps of bent axis was developed using the AMESim software, and the reliability of that was verified by the comparison with the experimental results. The hydraulic pipeline with a parallel line was used as the method to generate the phase interference of pressure wave. the dynamics characteristics of the hydraulic pipeline with a parallel line were analyzed by a transfer matrix method. the usefulness of the phase interference of pressure wave was investigated through the experiment and simulation. The results from the experiment and simulation said that the phase interference of pressure wave by the hydraulic pipeline with a paralle linel could reduce the discharge pressure wave of the pump well. The analysis model of the axial piston pumps of bent axis developed in this paper and the method of the phase interference by the hydraulic pipeline with a parallel line are expected to be helpful to achieve the design of the pump and to reduce the discharge pressure wave of the pump effectively.

  • PDF

Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique (Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS)

  • Lim, Ji-Hoon;Park, Young-Kyun;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • In this paper, we suggest the dynamic-response-free SMPS using a new high-resolution DPWM generator based on switched-capacitor delay technique. In the proposed system, duty ratio of DPWM is controlled by voltage slope of an internal capacitor using switched-capacitor delay technique. In the proposed circuit, it is possible to track output voltage by controlling current of the internal capacitor of the DPWM generator through comparison between the feedback voltage and the reference voltage. Therefore the proposed circuit is not restricted by the dynamic-response characteristic which is a problem in the existing SMPS using the closed-loop control method. In addition, it has great advantage that ringing phenomenon due to overshoot/undershoot does not appear on output voltage. The proposed circuit can operate at switching frequencies of 1MHz~10MHz using internal operating frequency of 100 MHz. The maximum current of the core circuit is 2.7 mA and the total current of the entire circuit including output buffer is 15 mA at the switching frequency of 10 MHz. The proposed circuit has DPWM duty ratio resolution of 0.125 %. It can accommodate load current up to 1 A. The maximum ripple of output voltage is 8 mV. To verify operation of the proposed circuit, we carried out simulation with Dongbu Hitek BCD $0.35{\mu}m$ technology parameter.

Magnetic Properties of RF Diode Sputtered $Ni_{80}Fe_{20}/SiO_2$ Multilayers (모양으로 유도된 자기 이방성을 가진 $Ni_{80}Fe_{20}/SiO_2$ 다층막의 자기적 성질)

  • Yun, Eui-Jung;Jung, Myung-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.2
    • /
    • pp.1-6
    • /
    • 2007
  • This study investigated the magnetic properties of $Ni_{80}Fe_{20}/SiO_2$ laminates with shape-induced magnetic anisotropy. The multilayer films were deposited on Si or upilex substrates, from separate $Ni_{80}Fe_{20}$ and $SiO_2$ (at %) alloy targets using a rf diode sputtering system. $Ni_{80}Fe_{20}/SiO_2$ laminates with a various number of bilayers (N) were prepared. The laminates with ellipse array patterns were prepared using photolithographic technique. The magnetic properties were measured at room temperature using a B-H hysteresisgraph and a high frequency permeameter. The several steps during domain wall reversal were observed in multilayer films, attributing to inter-magnetic layer coupling. Intrinsic uniaxial anisotropy field increases with N. The experimental values of the total anisotropy field are found to be in good agreement with the calculated values. This study utilized the shape anisotropy of the laminated film objects with small ellipse array patterns to induce a larger uniaxial anisotropy so as to maximize their operating frequency.

Design of Low Power Optical Channel for DisplayPort Interface (저전력 광채널용 디스플레이포트 인터페이스 설계)

  • Seo, Jun-Hyup;Park, In-Hang;Jang, Hae-Jong;Bae, Gi-Yeol;Kang, Jin-Ku
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents a transceiver design for DisplayPort interface using an optical channel. By converting the electronic channel to the optical channel, the DisplayPort's main channel can provide a high-speed data transmission for long distance. The design converting the electronic channel to the optical channel in the main channel and AUX channel of the DisplayPort is presented in this paper. Futhermore, the HPD signal transmission by using AUX channel is proposed. In order to minimize power consumption, this paper also proposed a method of controlling the TX block in the main link. The proposed system is designed by a FPGA and an optical module. The FPGA used 651 ALUT(adaptive look-up table)s, 511 resisters and 324 block memory bits. The maximum operating rate of the FPGA is 250MHz. With the proposed power control scheme, 740mW of power dissipation reduction can be achieved at the main link optical TX module.

A Study on the Safety Handling Method of KCG's Water Jet Propulsion Ship (해양경찰 Water Jet 추진함정의 안전 조함법 연구)

  • Yun, Chong-Gum;Pak, Chae-Hong;Park, Deuk-Jin;Jung, Cho-Yeong
    • Journal of Navigation and Port Research
    • /
    • v.41 no.6
    • /
    • pp.373-380
    • /
    • 2017
  • Operational errors caused by human factors, which is the major cause of marine accidents, include lack of knowledge, misunderstanding knowledge, and inadequate procedures. Recently, the type of propulsion mounted on KCG cutters has been diversified. In particular, the water jet propulsion unit, which was mainly installed in small boats, have been gradually expanded to medium and large size Coast Guard cutters, reaching 50% of the total. Axes types are divided into 2 to 4, and the bucket types are divided into Double Reverse Bucket(DRB) and Single Reverse Bucket(SRB); in these, the backward and steering control methods are completely different. Diversification of these operating systems can increase factors causing human error by the ships' operators. However, there is a lack of research on the maneuvering methods, considering the inherent active characteristics of each type of water jet. In this paper, we analyze the sideway method suitable for the condition of Coast Guard Exclusive wharf without assistance, based on the astern performance of each type. Then, a ship handling simulator was used for the experiment; they compared and verified through interviews of captains.

Membrane Fouling Control Effect of Periodic Water-back-flushing in the Tubular Carbon Ceramic Ultrafiltration System for Recycling Paper Wastewater (제지폐수 재활용을 위한 관형 탄소계 세라믹 한외여과장치에서 물 역세척의 막오염 제어 효과)

  • 김미희;박진용
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.190-203
    • /
    • 2001
  • In this study the discharged wastewater from a paper plant was filtrated by 4 kinds of tubular carbon ceramic ultrafiltration membranes with periodic water-back-flushing. We could investigate effects of watch-back-flushing period, transmembrane pressure (TMP) and flow rate, and find optimal operating conditions. The back-f1ushing time (BT) was fixed at 3 sec, and fi1tration times (FT) werc changed in 15~60 scc, TMP in 1.00~2.50$kg_{f}$/$cm^2$, and the flow rates in 0.27~1.75 L/min. The optimal conditions were discussed in 7he viewpoints of dimensionless permeate flux (J/J$_{0}$), total permeate volume ($V^T$) and resistance of membrane fouling ($R^f$). Optima1 back-flushing period was BT/FT=0.20, suggesting that the frequent back-flushing should decrease membrane fouling. Optimal TMP in the viewpoint of $V^T$ was 1.00~1.55$kg_{f}$/$cm^2$, suggesting that rising TMP should increase membrane fouling and decrease permeate flux. But, rising f1ow rate should decrease membrane fouling and increase permeate flux. Then, average rejection rates of pollutants filtratedby carbon ceramic membranes were 88~98 % for turbidity, 48~72% fort $COD_{cr}$ and 37~76% for TDS.

  • PDF

Defining the Tumour and Gross Tumor Volume using PET/CT : Simulation using Moving Phantom (양전자단층촬영장치에서 호흡의 영향에 따른 종양의 변화 분석)

  • Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.935-942
    • /
    • 2021
  • Involuntary movement of internal organs by respiration is a factor that greatly affects the results of radiotherapy and diagnosis. In this study, a moving phantom was fabricated to simulate the movement of an organ or a tumor according to respiration, and 18F-FDG PET/CT scan images were acquired under various respiratory simulating conditions to analyze the movement range of the tumor movement by respiration, the level of artifacts according to the size of the tumor and the maximum standardized uptake value (SUVmax). Based on Windows CE 6.0 as the operating system, using electric actuator, electric actuator positioning driver, and programmable logic controller (PLC), the position and speed control module was operated normally at a moving distance of 0-5 cm and 10, 15, and 20 reciprocations. For sphere diameters of 10, 13, 17, 22, 28, and 37 mm at a delay time of 100 minutes, 80.4%, 99.5%, 107.9%, 113.1%, 128.0%, and 124.8%, respectively were measured. When the moving distance was the same, the difference according to the respiratory rate was insignificant. When the number of breaths is 20 and the moving distance is 1 cm, 2 cm, 3 cm, and 5 cm, as the moving distance increased at the sphere diameters of 10, 13, 17, 22, 28, and 37 mm, the ability to distinguish images from smaller spheres deteriorated. When the moving distance is 5 cm compared to the still image, the maximum values of the standard intake coefficient were 18.0%, 23.7%, 29.3%, 38.4%, 49.0%, and 67.4% for sphere diameters of 10, 13, 17, 22, 28, and 37 mm, respectively.

Differences in Static Lower Extremity Alignment according to the History of Lateral Ankle Sprain: Efficacy and Limitation of Static Lower Limb Alignment Measurement as a Predictor of Lateral Ankle Sprain (외측 발목 염좌 병력에 따른 정적 하지 정렬 차이: 외측 발목 염좌의 예측인자로서 정적 하지 정렬 검사의 효용성과 한계점)

  • Jeon, Hyung Gyu;Ha, Sunghe;Lee, Inje;Kang, Tae Kyu;Kim, Eun Sung;Lee, Sae Yong
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.1-15
    • /
    • 2021
  • Objective: The aim of this study was to investigate 1) the difference in static lower extremity alignment (SLEA) according to a history of lateral ankle sprain (LAS), 2) to identify SLEA factors affecting LAS, and 3) to present the cut-off value and 4) the usefulness and limitations of the SLEA measurement. Method: This case-control study recruited 88 men (age: 27.78±4.69 yrs) and 39 women (age: 24.62±4.20 yrs) subjects with and without LAS. SLEA measurement protocol included Q angle, tibiofemoral angle, genu recurvatum, rear foot (RF) angle, tibal varum and torsion, navicular drop, ankle dorsiflexion range of motion (DF ROM). Independent t-test, logistic regression and receiver operating characteristic (ROC) curve were used for statistical analysis. Results: Men with a history of LAS had significantly smaller Q angles both in standing and in supine position, while women with a history of LAS had significantly greater DF ROM in non-weight bearing (NWB; p < 0.05). Logistic regression model suggests tibial varum (OR = 0.779, p = 0.021) and WB DF ROM (OR = 1.067, p = 0.045) were associated with LAS in men. In case of women, there were no significant SLEA factors for LAS, however, ROC curve analysis revealed standing RF angle (AUC = 0.647, p = 0.028) and NWB DF ROM (AUC = 0.648, p = 0.026) could be affecting factors for LAS. Conclusion: There are differences in SLEA according to the history of LAS, furthermore, the identified items were different by sex. In case of men, tibial varum and WB DF ROM affect LAS occurrence. Standing RF angle and NWB DF ROM of women could be a predictor for LAS. However, since the sensitivity and specificity in most of the SLEA measurements are low, kinematic in dynamic tasks should be considered together for a more accurate evaluation of LAS risk.