• 제목/요약/키워드: Operating condition

Search Result 3,034, Processing Time 0.032 seconds

A Configuration of Superconducting Power System Considering the Current Level & Electric Insulation Coordination of Superconducting Apparatus (초전도기기 전류레벨협조와 절연협조를 고려한 초전도전력시스템구성을 위한 기초연구)

  • Hong, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1208-1210
    • /
    • 1999
  • Design & operation power systems for meeting increase of electric power demand is becoming more difficult and complex. Some of limitations of conventional technology can be broken through by the application of superconductivity technology. This paper presents a new concept & image for the configuration of superconducting power system which has introduced superconducting(SC) generator, cable, transformer, fault current limiter(SFCL), SMES, etc. Engineering evaluation of each power apparatus and its assessment of application to power system were conducted. Futhermore, it is pointed that superconducting power system require a new operating condition. This is, SFCL should play a important part of quenching current level coordination to prevent the other superconducting devices from quenching. Its designing & operating condition including SFCL was discussed in viewpoint of quenching current level and insulation coordination of SC coil.

  • PDF

Development of Automatic Welding DB System using Panel PC (패널 PC를 이용한 용접 자동화 DB 시스템의 개발)

  • Kim, D.W.;Park, J.H.;Shin, D.R.;Park, H.S.;Jung, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2284-2287
    • /
    • 2004
  • In this paper, an automatic welding DB system using a panel PC is developed. In the developed system, a automatic welding system is remotely controlled to overcome the restriction of operating condition by a portable panel PC, and the DB system such as the operating condition and control data of automatic welding carriage is developed by ATMega128.

  • PDF

Performance Variations of Vaned Diffusers with Solidity and Exit Vane Angle (베인 디퓨저의 솔리디티와 출구 유동각에 따른 성능변화)

  • Cho, S.K.;Kang, S.H.;Cha, B.J.;Lee, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.422-427
    • /
    • 2000
  • The design of low-solidity vaned diffusers and the effect on the performance of a turbocharger compressor is discussed. The effect of vane number and turning angle was investigated while maintaining a basic design with a leading edge angle of $70^{\circ}$, leading and trailing edge radius ratios of 1.1 and 1.3. All results are compared with those obtained with the standard vaneless diffuser configuration and it was shown that all designs increased and shifted the pressure ratio to reduced flowrates. Despite the low-solidity configuration none of the vane designs provided a broad operating range, and the vane leading edge angle was not main factor that system went into the surge condition. The diffuser of higher trailing edge angle improved the flow range for the compressor to operate at lower flow region.

  • PDF

Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season (봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구)

  • Pyo, Jong-Hyun;Kim, Won-Seok;Cho, Hong-Hyun;Ryu, Nam-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

Decision of Lubricated Friction Conditions for Materials of Automobile Transmission Gear Using Neural Network

  • Cho Yon-Sang;Park Heung-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.583-590
    • /
    • 2006
  • It is hard to inspect the state of lubrication of an automobile transmission visually. Thus, it is necessary to develop a new inspection method. Wear debris can be collected from the lubricants of an operating transmission of an automobile, and its morphology will be directly related to the friction condition of the interacting materials from which the wear debris originated in the lubricated transmission. In this study, wear debris in lubricating oil are extracted by membrane filter $(0.45{\mu}m)$, and the quantitative values of shape parameters of wear debris are calculated by digital image processing. These shape parameters are studied and identified by an artificial neural network algorithm. The results of the study may be applicable to the prediction and diagnosis of the operating condition of transmission gear.

Seismic Analysis of Power Plant Piping System (발전소 배관계의 내진해석)

  • Kim, Jeong-Hyun;Lee, Young-Shin;Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.480-485
    • /
    • 2011
  • In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

  • PDF

A Seismic Analysis of Spent Fuel Handling Tool (사용후 핵연료 취급장비의 내진해석)

  • 김성종;이영신;김재훈;김남균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1210-1215
    • /
    • 2002
  • The spent fuel handling tool is used to handle the refuel bundle and treated by hoist rope on the bridge crane. The new developed handling tool of NPP(Nuclear Power Plant) should be conformed the structural stability under earthquake condition. In this study, the stress and seismic analysis of the handling tool are performed by finite element method. Using the Floor Response Spectrum(FRS) obtained through the time history analysis, the modal and seismic analysis under Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE) load conditions are carried out. Total 4 cases of different locations of the trolly and the hook are investigated. With the spring-damper element, the tension analysis of hoist rope is conducted. The stability of handling tool under earthquake load condition is conformed with regulatory guide.

  • PDF

The Analysis of Shaft Center Locus in the Refrigeration & Air-conditioning Rotary Compressor (냉동.공조용 로터리 콤프레서의 축심궤적 해석)

  • 조인성;장원수;김진문;김동우;오석형;정재연
    • Tribology and Lubricants
    • /
    • v.12 no.2
    • /
    • pp.65-73
    • /
    • 1996
  • Rapid increase of Refrigeration and Air conditioning system in modem industries brings attention to the urgency of core technology development in the area. This paper presents theoretical investigation of the lubrication characteristics of rotary compressor for refrigeration and air conditioning. In order to analyze the lubrication characteristics of the main & sub bearing of rotary compressor, the bearing force and locus of shaft center are analyzed by the dynamic analysis of rotary compressor and numerical analysis of Reynolds equation as the operating condition is changed in various ways. In this paper, we used the Runge-Kutta method for the dynamic analysis of rotary compressor and the SOR (Successive OverRelaxation) method for the numerical analysis of Reynolds equation. The result shows that the operating condition of sub bearing is severer than that of main bearing, and eccentricity ratio grows as the bearing force increases. It is believed that the result can be applied to the design of alternative refrigerant rotary compressor.

A Study on Performance Improvement in PEMFC (소면적 PEM연료전지 성능개선 연구)

  • Chon, Kwang Wu;Park, Chang Kwon;Lee, Ho Yeol;Oh, Byeong Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.4
    • /
    • pp.291-300
    • /
    • 2004
  • Performance of PEMFC is affected by many factors such as that of MEA, configuration of flow field, operating conditions, humidification, cooling and so on. In this study, in order to improve the performance of fuel cell, a small area fuel cell stack was made and its performance was tested under various operating conditions. Stack consists of 3 single PEM fuel cells. Channel is serpentine type and the active area of the electrode is $50cm^2$. The test results show that the peak power is 60W at $70^\circ{C}$ of stack temperature with humidification condition.

Operating Current Characteristics of a kA Class Conductor for a SMES device (SMES용 kA급 초전도도체의 운전전류 특성)

  • 류경우;최병주;김해종;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.3-6
    • /
    • 2003
  • We have developed a small-sized superconducting magnetic energy storage (SMES) device, which provides electric power with high quality to sensitive electric loads. In large magnets such as the SMES magnets the stability, which is determined by several factors, e.g. conductors cooling condition and operating current, magnets winding structure, is a crucial problem. The effect of the cooling condition, the copper ratio, and the conductor's size upon the recovery currents was investigated experimentally. The results indicate that the recovery current characteristics of the strands vary considerably according to their insulation method. In the fully insulated strands with a low copper ratio, the recovery current densities range from 10 to 20 % of their engineering critical current densities. The recovery current density of the 30-conductor with a cooling channel is about a factor of 1.8 higher than that without a cooling channel.

  • PDF