• Title/Summary/Keyword: Operating Requirement

Search Result 328, Processing Time 0.026 seconds

An Analysis of Operating Policies for Multi-Product Unit Load AS/RS (다품종 단위적재 자동창고 시스템의 운영정책 분석)

  • Park, Yang-Byeong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 1989
  • In the past few years, increasing numbers of automatic storage/retrieval system (AS/RS) using computer controlled storage/retrieval machine have been installed. This paper introduces two modeling approaches to determine the best operating policy for AS/RS : an M/G/1 queueing model and a computer simulation model. The operating policy consists of three elements. : the operation command cycle, the storage location method, and the operation dispatching rule. The analysis based on M/G/1 model is suitable for a quick and approximate evaluation, due to its inherent strict assumptions. The computer simulation can be used to perform a more realistic analysis. It is shown through the study that a significant improvement in the throughput and/or the space requirement can be expected by determining the best operating policy to a particular system. Most important, the computer simulation demonstrates its powerful capability in evaluating dynamic stochatic systems with imperfect information.

  • PDF

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

Analysis of Power Requirement of Agricultural Tractor by Major Field Operation (농업용 트랙터의 주요 농작업 소요동력 분석)

  • Kim, Yong-Joo;Chung, Sun-Ok;Park, Seung-Jae;Choi, Chang-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.79-88
    • /
    • 2011
  • The purpose of this study was to analyze power requirement of an agricultural tractor by major field operations. First a survey was conducted to obtain annual usage ratio of agricultural tractor by field operation. Plowing, rotary tillage, and loader operations were selected as major field operations of agricultural tractor. Second, a power measurement system was constructed with strain-gauge sensors to measure torque of four driving axles and a PTO axle, speed sensors to measure rotational speed of the driving axles and an engine shaft, pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to calculate power requirement. Third, the major field operations were experimented under fields with different soil conditions following planned operation paths. Power requirement was analyzed during the total operation period consisted of actual operation period (plowing, rotary tillage, and loader operations) and period before and after the actual operation (3-point hitch operating, forward and reverse driving, braking, and steering). Power requirement of tractor major components such as driving axle part, PTO part, main hydraulic part, and auxiliary hydraulic part were measured and calculated to determine usage ratio of agricultural tractor power. Results of averaged power requirement for actual field operation and total operation were 23.1 and 17.5 kW, 24.6 and 19.1 kW, and 14.9 and 8.9 kW, respectively, for plowing, rotary tillage, and loader operations. The results showed that rotary tillage required the greatest power among the operations. Averaged power requirement of driving axles, PTO axle, main hydraulic part, and auxiliary part during the actual field operation were 8.1, 7.8, 3.4, and 1.5 kW, respectively, and the total requirement power was about 70 % (20.8 kW) of the rated power. Averaged power requirement of driving axles, PTO axle, main hydraulic, and auxiliary hydraulic for the total operation period were 6.5, 6.0, 2.1, 0.9 kW, respectively, and total requirement power was about 52 % (15.5 kW) of the rated power. Driving axles required the greatest amount of power among the components.

Creating of Standard Operating Procedures for Chronic Inhlation and Carcinogenicity Test (흡입노출에 의한 만성·발암성시험 표준작업지침서 작성 연구)

  • Rim, Kyung-Taek;Kim, Soo-Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.578-586
    • /
    • 2014
  • Objectives: There is a requirement to establish the standard operating procedures(SOPs) for chronic inhalation/carcinogenicity testing, so we would like to set them appropriately. Methods and Results: We established SOPs according to guidelines from international organizations such as OECD, the US EPA, and relevant institutions in advanced countries. We also benchmarked other contract research organizations(CROs) in Korea. Conclusions: We created appropriate SOPs for chronic inhalation/carcinogenicity testing.

Cathodic Recirculation System Using a Dual-ejector to Improve Oxygen Utilization of a Submarine Fuel Cell

  • Kim, Min-Jin;Sohn, Young-Jun;Lee, Won-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.3
    • /
    • pp.193-197
    • /
    • 2010
  • In terms of the system efficiency, it is very useful to apply the ejector into the fuel recirculation system of a fuel cell system since the ejector needs no parasitic power to operate. Since the conventional automotive fuel cell use hydrogen and air as their fuel, the only hydrogen is needed to be recirculated for the better fuel efficiency. On the other hand, the submarine fuel cell needs both hydrogen and oxygen recirculation systems because the submarine drives under the sea. In particular, the cathodic recirculation has to meet the tougher target since the oxygen based pressurized stack generally used in the submarine applications generates the significant amount of the water in the stack during the operation. Namely, the oxygen utilization has designed less than 50% in the whole operating range for the better exhausting of the generated waters. And thereby in terms of the oxygen utilization, the entrainment ratio of the ejector should be more than 1 within the whole operating range. However, the conventional ejector using a constant nozzle can not afford to satisfy the mentioned critical requirement. To overcome the problem, the dual-ejector and its control strategy are designed. The performance of the proposed dual-ejector is verified by the experiments based on the real operating conditions of the target submarine system. Furthermore, the proposed design method can be used for the other fuel recirculation system of a large-scale fuel cell system with the critical requirement of the fuel utilization.

Design and Implementation of the Transmit and Receive Equipments for Wide Band Signals of a Spaceborne High Resolution Synthetic Aperture Radar (위성탑재 고해상도 합성개구 레이다용 광대역 신호 송 수신장치 설계 및 제작)

  • Ka, Min-Ho;Jeon, Byung-Tae;Kim, Se-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.3
    • /
    • pp.44-51
    • /
    • 2001
  • In general, the realization of spaceborne system is constrained by its space environment. In this paper, we suggest chirp stitching technique which generates and processes wideband radar signal with minimum hardware, design and implement transmit/receive equipments and operating programs to satisfy the requirement of this spaceborne high resolution SAR(Synthetic Aperture Radar). We apply the top down design approach to this system, and divide hardware into equipment, module and circuit levels, and software into SR(Software Requirement), AD(Architecture Design), DD(Detailed Design) and coding levels, and then extract each requirement to satisfy the wideband requirement of this spaceborne high resolution SAR. We, at first, test the hardware functions, confirm the wideband handling capability of this system with 85MHz wideband signals generated from two 42.5MHz narrow band signals, and show that this system can be used in spaceborne high resolution SARs.

  • PDF

A Study on the Effects of ISO 14001 Environment Management Systems's Requirement on Management Performance : Focused on the Manufacturer in the Small Businesses (ISO 14001 환경경영시스템의 요구사항이 경영성과에 미치는 영향에 관한 연구 : 중소기업 제조업체를 중심으로)

  • Park, Hyung-Geun;Kim, Geun-Sik;Kim, Yong-Jun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.22-29
    • /
    • 2015
  • Many enterprises have been adopting management systems good enough for them and operating the schemes to have competitive edge better than their competitor. One of the finest systems that most companies have been selecting is ISO 14001. ISO 14001, environment management system, is widely known as advancing internal efficiency and productivity in the various industries. As a result, the number of companies that have adopted ISO 14001's certification have been increasing continuously year by year since ISO 14000 standard was called in 1994s from ISO 18000 standard that originally used. The purpose of this study is to present that ISO 14001's requirement execution influences on management performance in the small manufacturer. In order to carry out this research, we obtained 96 survey sheets and inspected ten assumptions based on the reliability, validity of the questionnaires. The results of regression analysis are summarized as follows; First, the three factors of ISO 14001 requirement, plan, implementation and operation and management consideration, have an important effect on the operational performance. Second, the three elements of ISO 14001 requirement, environment policy, implementation and operation and management consideration, affect to the financial performance significantly. Based on the results, it is sure that the companies that execute the factors of implementation and operation and management policy have a good performance to achieve operational and financial performance so that it is important to clarify the member's role, authority and follow the procedure by a company's process. Also, the truth shows CEO's continuous will and periodical review of ISO 14001 influence on management performance as well.

Design Parameters of A Six-bar Linkage Vibrating Digger (6절 링크를 이용한 진동굴취기의 설계요인)

  • 문학수;강화석
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2003
  • An oscillating digger mechanism was designed, constructed. and tested. The mechanism is consisted of a six-bar linkage, one four-bar linkage was fer the digger blade and the other one fur variable soil-crop separation. Experimental variables were amplitude(3, 6, 9 mm). frequency(11.2, 14.9. 17.0 Hz), and forward speed of tractor(0.91, 1.13, 1.56 km/h). Each combination of these variables was replicated three times to measure the draft and torque for power requirement evaluation. and the broken-up soil height on the soil separation sieve mechanism. Four parameters λ(the ratio of vibration speed to forward velocity), p(the ratio of vibration acceleration to forward velocity), K(the ratio of vibration acceleration to gravitational acceleration), and T(the product of λ and K) were induced from three experimental variables: amplitude, frequency, and tractor speed. And the power requirement and soil separation ability were analyzed by regression. Though λ and K were known to be the representative parameters. T was the most moderate one to explain draft. torque. and soil separation in this study. It was estimated that the T equal to or greater than 2.4 was the minimum recommended value. Figure 18 would be useful fir the selection of amplitude. frequency, or operating tractor speed once any two variables are known.

Development of An Onion Peeler (I) - Root cutting equiment - (양파 박피기 개발(I))

  • 민영봉;김성태;정태상;최선웅;김정호
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.301-310
    • /
    • 2002
  • With a purpose to manufacture an onion peeler, the root cutting equipment of the onion could be attached to a prototype onion peeler was developed. Before the experiment, the distribution of the dimensions of the Korean native onion were measured. And some types of the blades to cut and remove the root of the onion were designed and such characteristics as feasible revolution, conveying speed, and power requirement were investigated. From the result of the test, the selected one among the various cutters was the wing type blade with the round blade to cut out the root and with the vertical blade to cut a circular line. The optimum operating conditions of the wing type blade were revealed the revolution with no load was at 630 rpm, and the conveying speed was 0.08 m/s. Under these conditions, the maximum torque was 5.25 kg·m and the power requirement was 33 W, respectively.

Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load (싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정)

  • Park, No-Jung;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF