• Title/Summary/Keyword: Operating Pressure

Search Result 2,518, Processing Time 0.024 seconds

The Effect of Exhaust Gas Recirculation (EGR) on Combustion Stability, Engine Performance and Exhaust Emissions In a Gasoline Engine

  • Jinyoung Cha;Junhong Kwon;Youngjin Cho;Park, Simsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.10
    • /
    • pp.1442-1450
    • /
    • 2001
  • The EGR system has been widely used to reduce nitrogen oxides (NO$\_$x/) emission, to improve fuel economy and suppress knock by using the characteristics of charge dilution. However, as the EGR rate at a given engine operating condition increases, the combustion instability increases. The combustion instability increases cyclic variations resulting in the deterioration of engine performance and emissions. Therefore, the optimum EGR rate should be carefully determined in order to obtain the better engine performance and emissions. An experimental study has been performed to investigate the effects of EGR on combustion stability, engine performance,70x and the other exhaust emissions from 1.5 liter gasoline engine. Operating conditions are selected from the test result of the high speed and high acceleration region of SFTP mode which generates more NO$\_$x/ and needs higher engine speed compared to FTP-75 (Federal Test Procedure) mode. Engine power, fuel consumption and exhaust emissions are measured with various EGR rate. Combustion stability is analyzed by examining the variation of indicated mean effective pressure (COV$\_$imep/) and the timings of maximum pressure (P$\_$max/) location using pressure sensor. Engine performance is analyzed by investigating engine power and maximum cylinder pressure and brake specific fuel consumption (BSFC)

  • PDF

An experimental study on the stern bottom pressure distribution of a high-speed planing vessel with and without interceptors

  • Seok, Woochan;Park, Sae Yong;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.691-698
    • /
    • 2020
  • In this study, the effects of hydrodynamic interceptors on a high-speed vessel were investigated to identify the operating principle based on experiments. Model tests were performed using a high-speed towing carriage. The resistance, trim and rise of Center of Gravity (CG) of the high-speed vessel were measured for various ship speeds and interceptor heights. As the interceptor height increased, the trim and rise of CG were reduced. In order to quantitatively analyze these phenomena, the pressure at the stern bottom was measured using tactile sensors. The reliability of the measured results from the tactile sensors was verified through repeat tests. The pressure on the stern bottom increased in proportion to the interceptor height, as the interceptor partially blocked the flow there. Then, the trim was reduced. However, as the ship speed increases, the pressure at the location close to the interceptor decreases when the interceptor height is small, leading to increased trim. Therefore, the interceptor height for running attitude control should be carefully determined considering multiple factors in the operating condition of the high-speed planing hull.

A Study on Reduction of Cavitation with Orifice on High Differential Pressure Control Butterfly Valve (오리피스를 이용한 고차압 제어 버터플라이 밸브의 캐비테이션 저감에 관한 연구)

  • Lee, Sang-Beom
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.131-139
    • /
    • 2022
  • The exchange of goods over the sea is a situation in which the amount of trade between countries is gradually increasing. In order to maintain the optimal operating condition, the ship maintains stability and optimal operating conditions by inserting or withdrawing ballast water from the ballast tank according to the loading condition of cargo capacity is also increasing. Control valves play an important role in controlling fluid flow in these pipes. When the flow rate is controlled using a control valve, problems such as cavitation, flashing, and suffocating flow may occur due to high differential pressure, and in particular, damage to valves and pipes due to cavitation is a major problem. Therefore, in this study, the cavitation phenomenon is reduced by installing orifices at the front and rear ends of the high differential pressure control butterfly valve to reduce the sudden pressure drop at the limiting part of the butterfly valve step by step. The flow coefficient according to the shape of the orifice, the degree of cavitation occurrence, and the correlation were analyzed using a CFD(Cumputational Fluid Dynamics), and an optimal orifice design for reducing cavitation is derived.

Characteristics of the Concentration Process of Lactobacillus Cell Using a Ceramic Membrane (세라믹막을 이용한 Lactobacillus cell의 농축 공정의 특성)

  • Lee Yong Taek;Song Min-Ho
    • Membrane Journal
    • /
    • v.14 no.3
    • /
    • pp.192-200
    • /
    • 2004
  • It is an anaerobic germ that Lactobacillus cell concentrated using ceramic membrane has high stability and long lifetime as compared with polymeric membrane. The effects of operating pressure, temperature, crossflow velocity on cell harvesting have been studied. Also the variation of flux and transmembrane pressure (TMP) with increasing concentration ratio and the change of TMP at constant concentration ratio (volumetric concentration factor: VCF) regarding the optimization have been examined. It showed that the permeate flux increased gradually with the increasing of transmembrane pressure, crossflow velocity, and volumetric concentration factor. The higher initial flux was due to the reduction of viscosity at elevated temperature. However, as operating time progressed, the effect of temperature was negligible since the effect of viscosity became minor. As a result, that operate in a constant concentration ratio, decreased degree could know that become slowly although the flux decreases according as operating time progressed. The flux is a very stable in the condition of constant VCF range. The yield of Latobaciilus (PS 406) which was cultivated at $37^{\circ}C$ was concentrated about 4.9{\times}10^9$ after operation.

Performance Evaluation and Improvement of Medium and Small Scale Rice Polishers(II) - medium scale rice polisher - (중.소형 연미기의 성능평가 및 성능개선에 관한 연구(II) - 중형 연미기에 대하여 -)

  • 정종훈;권홍관
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.445-456
    • /
    • 1998
  • This study was carried out to evaluate the performance of a medium scale rice polisher of 2.5 t/h and to improve its performance for producing the clean rice with high quality. The maximum internal pressure, broken rice ratio. whiteness in the rice polisher were investigated, and the effects of outlet resistance, water spraying rate, shaft revolution speed and rice moisture content on the polishing performance were analyzed to find out proper operating conditions. The conclusions of this study were as follows: 1. In the performance evaluation of the polisher, the broken rice ratio increment of 0.1%, the max. internal pressure of about 11 N/${cm}^2$, and whiteness increment of 2.2~3.7 resulted at the conditions of 20 PS driving power, 950 rpm, 150 cc/min water spraying rate, 44.1 Nㆍcm outlet resistance and about 15% rice moisture content. 2. Though max. internal pressure and whiteness at the 17% rice moisture content were higher than those at the 15% moisture content under the same operating conditions of the polisher, but the broken rice rate at the 17% moisture content was absolutely low compared with that at 15% moisture content. The water spraying effect to reduce broken rice and to increase whiteness was much significant at the 15% moisture content not significant at 17% moisture content. 3. The main parameter of the performance was outlet resistance, and low resistance of about 44.1 Nㆍcm was recommended at the polisher. 4. The proper water spraying rate in the polisher was about 150 cc/min. 5. As the shaft revolution speed decreased from 950 rpm and 800 rpm to 650 rpm, the broken rice ratio increased and whiteness decreased. 6. As the driving power of the polisher increased from 20 PS to 30 PS, the max. internal pressure decreased by about 1~2.5 N/${cm}^2$ and whiteness increased by about 1~2, but the broken rice rate was not changed. 7. The proper operating conditions of the polisher seemed to be the revolution speed of 800-950 rpm, the water spraying rate of about 150 cc/min, the oulet resistance of about 44.1 N.cm and 30 PS driving power.

  • PDF

Investigation of Pressure Drop for a Pseudo-plastic Fluid Flow in Isosceles Triangle Pipes (이등변삼각형 단면을 갖는 파이프 내의 Pseudo-Plastic 유체유동에 대한 압력강하의 연구)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.30-35
    • /
    • 2009
  • Numerical Calculations for dimensionless pressure drop (friction factor times Reynolds number) have been obtained for fully developed laminar flow of MPL(Modified Power Law) fluid in isosceles triangle pipes. The solutions are valid for Pseudoplastic fluids over a wide range from Newtonian behavior at low shear rates through transition region to power law behavior at higher shear rates. The analysis identified a dimensionless shear rate parameter which for a given set of operating conditions specifies where in the shear rate range a particular system is operating, i.e., Newtonian, transition or power law region. The numerical calculation data of the dimensionless pressure drop for the Newtonian and power law regions are compared with previously published asymptotic results presenting within 0.16 % in Newtonian region and 2.98 % in power law region.

  • PDF

A Numerical Analysis on the System Impedance in a Fan Cooling System (Fan 냉각장치에서 System 저항에 관한 수치해석)

  • Kim, Dong-Il;Bok, Ki-So;Lee, Seung-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1424-1429
    • /
    • 2004
  • To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance and it has been usually examined with the fan tester(wind tunnel) based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated.

  • PDF

A Study on the Structure of Turbulent Flow Fields According to the Operating Loads of Three-Dimensional Small-Size Axial Fan by Large Eddy Simulation (대규모와 모사에 의한 3차원 소형축류홴의 운전부하에 따른 난류유동장 구조에 대한 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.80-85
    • /
    • 2015
  • The unsteady-state, incompressible and three-dimensional large eddy simulation(LES) was carried out to analyze the structure of turbulent flow fields according to the operating loads of three-dimensional small-size axial fan(SSAF). LES shows the best prediction performance in comparison with any other Reynolds averaged Navier-Stokes(RANS) method because static pressure coefficients analysed by LES show a little bit larger than measurements including all flow coefficients. Also, it can be known that the wake of SSAF is divided into from axial flow to radial flow before and behind stall region according to the increase of static pressure through LES analysis.

The design of heat exchanger of small size steam boiler using the concentric annuli tube with pin fin (동심원관-pin fin 열교환기를 이용한 소형 증기보일러 대류실 설계)

  • Kim, Sungil;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.115-118
    • /
    • 2012
  • The configurations of the heat exchanger of the boiler can be determined from the trade-off between the heat transfer area which is related to the capital cost and the pressure drop which is related to operating cost. In this study, 3.5 ton/hr small size marine boiler having concentric annuli tubes is the design boiler. To determine the optimizing point, according to diameter, number, length of tube, heat transfer, pressure drop, operating cost and capital cost have been calculated. Also, when the fin tube is replaced by the bare tube design parameters changed have been calculated.

  • PDF

Study of the Linear Compressor Characteristics of The Stirring Refrigerator (스터링 냉동기의 선철압축기 운전특성에 관한 연구)

  • 홍용주;박성제;김효봉;고득용;김종학;유병건
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.49-54
    • /
    • 2001
  • The purpose of this study is to analyze the characteristics of the linear compressor for Stirling refrigerator. To ensure high performance and long life of the FPFD(Free Piston. Free Displacer) type Stirling refrigerator, the operating parameters of the linear compressor should be optimized. The experimental results show that the operating frequency of the linear compressor has significant effect on the input power characteristics. and that the compressor with higher charging pressure of working fluid has high pressure ratio. For the high performance of the linear compressor. compressor should be operated at the resonance frequency with respect to the given charging pressure.

  • PDF