• 제목/요약/키워드: Operating Modes

검색결과 475건 처리시간 0.027초

Removal of Total Suspended Solids by a Foam Fractionator in a Simulated Seawater Aquaculture System

  • Peng, Lei;Jo, Jae-Yoon
    • 한국양식학회지
    • /
    • 제16권4호
    • /
    • pp.216-222
    • /
    • 2003
  • In a simulated seawater aquaculture system, effects of different operating factors like the superficial air velocity (SAY), hydraulic residence time (HRT), protein concentration and foam overflow height on the removal of total suspended solids (TSS) by a foam fractionator, with 20 cm diameter and 120 cm height, were investigated. This experiment was performed on batch and consecutive modes for different combinations of the tested factors, using synthetic wastewater. In 5 consecutive trials, TSS concentration in culture tank water decreased faster, when the foam fractionator was operated at higher SAV and lower HRT. In batch trials, with increasing SAV, TSS removal rate increased, but decreased with increasing HRT. Higher protein concentration in the bulk solution resulted in higher TSS removal rate. TSS concentration in the collected foam condensates increased but the foam overflow rate decreased with increasing foam overflow height. Foam fractionation was effective for removing TSS in seawater aquaculture systems and its performance largely depended on the operating parameters, especially superficial air velocity.

전자식안정기의 설계기준 및 전도노이즈 저감 (The Design Criteria and Conduction Noise Reduction of Electronic Ballasts)

  • 권진욱;최인식;박영진;윤덕종;홍순찬
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.409-419
    • /
    • 1994
  • This paper deals with the design criteria and conduction noise reduction of electronic ballast system which is based on half-bridge series inverters. The system is theoretically analyzed in six modes and operating frequency range is selected to obtain the high efficacy and no sound noise. It is proposed the criteria for determining the values of L and C which are the dey points in system design Because of high operating frequency, electromagnetic noise, especially conduction noise, is a serious problem in electronic ballasts. To reduce the conduction noise, the operation and attenuation characteristics of noise filter are analyzed and the method to determine the values of filter elements is proposed. Also, the parasitic components of the inductor and capacitor are taken into consideration in filter analysis. Digital simulations and experiments are carried out to prove the theoretical results. And perfor mances of the system are verified through tests.

지하역사에서의 화재연기거동 실험 (Experiments of Smoke Behavior in an Underground Subway Station)

  • 김동현;장용준;박원희
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

CVT의 변속 알고리듬과 응답특성 (Shifting Algorithm and Response Characteristics of CVT)

  • 성덕환;김현수
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.9-17
    • /
    • 1994
  • In this study, a shifting algorithm of CVT was suggested for the two(2) driving modes : (1) power mode and (2) economy mode. Shifting algorithm must be obtained to make the engine run on the optimum operating line for the desired performance of the vehicle. Optimum operating lines of the engine were obtained by connecting the shortest way of the iso-power lines for the power mode and by connecting the shortest way of the BSFC curves for the economy mode. Also dynamic model of CVT vehicle was derived considering the throttle and the brake operation. By using the shifting algorithm and the CVT vehicle model, numerical simulations were performed to estimate the performance of CVT. Simulation results showed that comparing the performance of the conventional 4-speed automatic transmission, acceleration performance of the CVT vehicle was almost same with the AT vehicle for the power mode and the fuel economy of CVT was 14% superior than that of AT for the economy mode.

  • PDF

넓은 입·출력 전압이득 특성을 갖는 3 브리지 LLC 공진컨버터 (A 3-Bridge LLC Resonant Converter with Wide Input/Output Voltage Gain Characteristics)

  • 유상재;장기찬;김은수;전용석;국윤상
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.142-151
    • /
    • 2020
  • This paper presents a DC/DC LLC resonant converter with wide input/output voltage gain characteristics and its control method for efficiency improvement. For a wide input/output voltage gain characteristics without designing small transformer magnetization inductance, the proposed converter changes the topology into three modes of operation according to the main switch switching pattern. In each operating mode, variable LINK voltage modulation and frequency modulation were performed to control output voltage and improve operating efficiency. A prototype of a 5-kW DC/DC LLC resonant converter was built and tested to verify the validity and applicability of the proposed converter.

Integrated Model for Assessment of Risks in Rail Tracks under Various Operating Conditions

  • G. Chattopadhyay;V. Reddy;Larsson, P-O
    • International Journal of Reliability and Applications
    • /
    • 제4권4호
    • /
    • pp.183-190
    • /
    • 2003
  • Rail breaks and derailments can cause a huge loss to rail players due to loss of service, revenue, property or even life. Maintenance has huge impact on reliability and safety of railroads. It is important to identify factors behind rail degradation and their risks associated with rail breaks and derailments. Development of mathematical models is essential for prediction and prevention of risks due to rail and wheel set damages, rail breaks and derailments. This paper addresses identification of hazard modes, estimation of probability of those hazards under operating, curve and environmental condition, probability of detection of potential hazards before happening and severity of those hazards for informed strategic decisions. Emphasis is put on optimal maintenance and operational decisions. Real life data is used for illustration.

  • PDF

수열원 냉난방 동시형 히트펌프 시스템의 실외 열교환기 유량제어를 통한 성능개선에 관한 연구 (A Study on the Performance Improvement of a Simultaneous Heating and Cooling Water Source Heat Pump System by Controlling of the Refrigerant Flow Rate in an Outdoor Unit)

  • 배흥희;이동혁;이상헌;김병순;안영철
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.131-136
    • /
    • 2013
  • The present study has conducted cycle design and control technology of a water source VRF heat pump system. Previously, study of a simultaneous heating and cooling in an air source VRF heat pump system has been conducted. However, performance data and design methods for simultaneous heating and cooling in a water source VRF heat pump system are limited in the literature, due to various system parameters and operating conditions. In this study, the operating characteristics and performances of a simultaneous heating and cooling heat pump system are carried out, in simultaneous operation modes. Control logics of an EEV are developed for flow rate control to the outdoor unit, and are verified. When the control logics are applied, the simultaneous cooling and heating performances are sufficiently achieved, and system COPs are increased by up to 23.4%.

모니터 기능을 갖는 통신기기용 전원 시스템 (Power supply system of the telecommunication equipment with monitoring function)

  • 이중기;김영태;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF

FreeBSD 커널 기반의 침입 차단 시스템 성능 분석 (A Performance Analysis of Firewall on the FreeBSD Kernel)

  • 박창서
    • 한국정보통신학회논문지
    • /
    • 제7권8호
    • /
    • pp.1726-1731
    • /
    • 2003
  • 인터넷을 통해서 침입하는 해커나 침입자로부터 기관의 내부 정보시스템을 보호하기 위하여 침입 차단 시스템(firewall)의 사용이 보편화되고 있다. 하지만 사용자 입장에서는 침입 차단 시스템의 성능을 확인 할 수 없을 뿐 아니라, 동작 모드(브리지 모드(Bridge Mode), 게이트웨이 모드(Gateway Mode))에 따른 성능 차이를 알 수 없다. 이러한 문제를 해결하기 위하여 본 논문에서는 침입 차단 시스템의 운영체제(Windows 2000, Linux, FreeBSD) 환경에 따른 성능을 분석하였다. 끝으로 FreeBSD 커널 기반의 침입 차단 시스템을 서로 다른 동작 모드에서 성능을 비교하고 침입 차단 정책 수가 성능에 미치는 영향에 대하여 분석하였다.

Reactive Power and Soft-Switching Capability Analysis of Dual-Active-Bridge DC-DC Converters with Dual-Phase-Shift Control

  • Wen, Huiqing;Su, Bin
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.18-30
    • /
    • 2015
  • This paper focuses on a systematical and in-depth analysis of the reactive power and soft-switching regions of Dual Active Bridge (DAB) converters with dual-phase-shift (DPS) control to achieve high efficiency in a wide operating range. The key features of the DPS operating modes are characterized and verified by analytical calculation and experimental tests. The mathematical expressions of the reactive power are derived and the reductions of the reactive power are illustrated with respect to a wide range of output power and voltage conversion ratios. The ZVS soft-switching boundary of the DPS is presented and one more leg with ZVS capability is achieved compared with the CPS control. With the selection of the optimal operating mode, the optimal phase-shift pair is determined by performance indices, which include the minimum peak or rms inductor current. All of the theoretical analysis and optimizations are verified by experimental tests. The experimental results with the DPS demonstrate the efficiency improvement for different load conditions and voltage conversion ratios.