• Title/Summary/Keyword: Operating Method

Search Result 6,098, Processing Time 0.038 seconds

Reduction of an Operating Voltage of Liquid Crystal Display based on Kerr Effect

  • Kim, Min-Su;Kim, Mi-Young;Kang, Byeong-Gyun;Kim, Mi-Kyung;Yoon, Su-Kin;Choi, Suk-Won;Lee, Gi-Dong;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.637-640
    • /
    • 2009
  • The LCD based on Kerr effect is highly interesting because it uses an optically isotropic state with no need of alignment layer and it shows sub-millisecond response time. The problem of the device is that it requires very high operating voltage and the transmittance is relatively low compared with other LCDs that use nematic LC. In this work, we study on various electrode structures and driving method which can lower operating voltage.

  • PDF

An Analysis of Operating Policies for Multi-Product Unit Load AS/RS (다품종 단위적재 자동창고 시스템의 운영정책 분석)

  • Park, Yang-Byeong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 1989
  • In the past few years, increasing numbers of automatic storage/retrieval system (AS/RS) using computer controlled storage/retrieval machine have been installed. This paper introduces two modeling approaches to determine the best operating policy for AS/RS : an M/G/1 queueing model and a computer simulation model. The operating policy consists of three elements. : the operation command cycle, the storage location method, and the operation dispatching rule. The analysis based on M/G/1 model is suitable for a quick and approximate evaluation, due to its inherent strict assumptions. The computer simulation can be used to perform a more realistic analysis. It is shown through the study that a significant improvement in the throughput and/or the space requirement can be expected by determining the best operating policy to a particular system. Most important, the computer simulation demonstrates its powerful capability in evaluating dynamic stochatic systems with imperfect information.

  • PDF

The Blocking of buffer overflow based attack for Linux kernel (리눅스 시스템의 버퍼 오버플로우 공격 대응 기법)

  • Kim, Jeong-Nyeo;Jeong, Gyo-Il;Lee, Cheol-Hun
    • The KIPS Transactions:PartA
    • /
    • v.8A no.4
    • /
    • pp.385-390
    • /
    • 2001
  • In this paper, we describe a blocking method of buffer overflow attack for secure operating system. Our team developed secure operating system using MAC and ACL access control added on Linux kernel. We describe secure operating system (SecuROS) and standardized Secure utility and library. A working prototype able to detect and block buffer overflow attack is available.

  • PDF

Optimized design for operating system model of automated container terminal in Korea (우리나라에 적합한 자동화 터미널의 운영시스템 모델 설계)

  • 홍동희
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.62-67
    • /
    • 2002
  • Construction of automated terminal is urgently demanded to gain the foundation of hub-port in north east Asia. Therefore I suggest an adequate operating system model of automated terminal in Korea. In this paper the aim of automated terminal operating system is satisfied, four basic models are divided according to moving course of export and import cargo of each automated equipments, several input data are changed and analyzed dynamically by Trial and Error method, and then an optimized operating system model is designed. It is a Premise that all the yard equipments described in this paper must be automatic except quay crane.

  • PDF

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

AVR Parameter tuning with On-line System model using Parameter optimization technique (On-line 시스템 모델과 파라메터 최적화 기법을 이용한 AVR의 최적 파라메터 튜닝)

  • Kim, Jung-Mun;Moon, Seung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1242-1244
    • /
    • 1999
  • AVR parameter tuning for voltage control of power system generators has generally been done with the open-circuit model of the synchronous generator. When the generator is connected on-line and operating at rated load conditions, the AVR operates in an entirely different environment from the open-circuit conditions. This paper describes a new method for AVR parameter tuning using optimization technique with on-line linearized system model. As this method considers not only the on-line models but also the off-line open-circuit models, AVR parameters tuned by this method can give the sufficiently stable performance at the open-circuit commissioning phase and give the desired performance at the operating conditions. Also this method estimates the optimum parameters for desired performance indices that are chosen for satisfying requirements in some practical applications, the performance of the AVR can satisfy the various requirements.

  • PDF

Sampling Inspection Plans for Defect

  • Jeong, Jeong-Im;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.867-877
    • /
    • 2004
  • The sequential sampling inspection method is an extension of the multiple-sampling methods, and its theory is based on the sequential probability ratio test (SPRT) of Wald. In this paper, the characteristics of SPRT for testing the number of defects are approximated by using the estimated excess over the boundaries. The use of the estimated excess shows good performances in estimating the operating characteristic function and the average sample number of SPRT compared to the method by neglecting the excess. It also makes it possible to determine the boundary values which satisfy the desired error probabilities.

  • PDF

Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method (영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리)

  • 손승찬;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.409-416
    • /
    • 2000
  • In case of operating two converters in parallel with ZCT operation method using one current sensor for fault tolerance by system characteristics, identifying fault detection and isolation is difficult of which converter is fault since the ZCT output is a difference of two converters' supply current when a converter has fault. This thesis suggest a fault detection and isolation method of converter in case of operating two converters in parallel for fault tolerant system and verified this suggested method through an experiment.

  • PDF