• Title/Summary/Keyword: Opening area

검색결과 759건 처리시간 0.028초

A Study on the Cremation Status of Public Cremation Facilities By Jurisdiction Area and Outside of the Jurisdiction Area Targeting Users of E-Haneul Funeral Information System in Jeollabuk-do

  • Choi, Jae-sil;Kim, Jeong-lae
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.187-197
    • /
    • 2021
  • We present following research summary and implications through the analysis of the research. First, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation increases to annual average of 5.5% of the rate, and it has a positive effect on increasing rate of the cremation. Therefore, a policy of expanding the supply of public cremation facilities should be pursued to improve cremation rate in the area of uninstalled public cremation facilities. Second, the before the opening of public cremation facilities compared to new opening of those, the number of the corpse cremation has increased to the annual average 3,623 people(56.9%) at jurisdiction area, while it has decreased to 949 people (28.3%) at the out of the jurisdiction area. The active efforts and building the funding expansion should be made to establish public cremation facilities of the central and local governments to improve convenience of the use of public cremation facilities. Third, since the before and after opening of public cremation facilities at Jeongeup City lead to great effect on demand of jurisdiction area and out of the jurisdiction area, the cremation demand should be reduced through the supply expansion of public cremation facilities and differentiation strategy to control cremation demand at the out of the jurisdiction area, focusing on metropolitan areas with high cremation demand, such as metropolitan areas or metropolitan cities.

Ultimate strength of simply supported plate with opening under uniaxial compression

  • Yu, Chang-Li;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.423-436
    • /
    • 2012
  • Unstiffened plates are integral part of all kinds of structures such as ship and offshore oil platforms. Openings are unavoidable and absolutely reduce the ultimate strength of structures. In this study, the finite element analysis package, ABAQUS, is used to analyze the behavior of unstiffened plate with rectangular opening. The rectangular opening form is divided into two cases. In case1, opening depth is constant, but opening width is varied. Meanwhile, in case2 opening width is fixed and opening depth is varied. Besides, for the two different form opening, the effect of plate slenderness parameter (${\beta}$), opening area ratio (AR) and opening position ratio (PR) on the ultimate strength of plate with opening under axial compression are presented. It has been found that the ultimate strength of plate ofcase1is much more sensitive to the plate slenderness parameter (${\beta}$) and opening area ratio (AR) than that of case2. However, for case1, opening position (PR) almost has no effect on the ultimate strength, whereas, regardingcase2, the influence of opening position (PR) depends on the plate slenderness parameter (${\beta}$). Based on nonlinear regression analysis, three design formulae are not only developed but also approved reasonably for the practical engineering design.

Internal pressures in buildings with a dominant opening and background porosity

  • Kim, P.Y.;Ginger, J.D.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.47-60
    • /
    • 2013
  • A dominant opening in a windward wall, which generates large internal pressures in a building, is a critical structural design criterion. The internal pressure fluctuations are a function of the dominant opening area size, internal volume size and external pressure at the opening. In addition, many buildings have background leakage, which can attenuate internal pressure fluctuations. This study examines internal pressure in buildings for a range of dominant opening areas, internal volume sizes and background porosities. The effects of background porosity are incorporated into the governing equation. The ratio of the background leakage area $A_L$ to dominant opening area $A_W$ is presented in a non-dimensional format through a parameter, ${\phi}_6-A_L/A_W$. Background porosity was found to attenuate the internal pressure fluctuations when ${\phi}_6$ is larger than 0.2. The dominant opening discharge coefficient, ${\kappa}$ was estimated to lie between 0.05 to 0.40 and the effective background porosity discharge coefficient ${\kappa}^{\prime}_L$, was estimated to be between 0.05 to 0.50.

Stresses around an underground opening with sharp corners due to non-symmetrical surface load

  • Karinski, Y.S.;Yankelevsky, D.Z.;Antes, M.Y.
    • Structural Engineering and Mechanics
    • /
    • 제31권6호
    • /
    • pp.679-696
    • /
    • 2009
  • The paper aims at analyzing the stress distribution around an underground opening that is subjected to non-symmetrical surface loading with emphasis on opening shapes with sharp corners and the stress concentrations developed at these locations. The analysis is performed utilizing the BIE method coupled with the Neumann's series. In order to implement this approach, the special recurrent relations for half plane were proven and the modified Shanks transform was incorporated to accelerate the series convergence. To demonstrate the capability of the developed approach, a horseshoe shape opening with sharp corners was investigated and the location and magnitude of the maximum hoop stress was calculated. The dependence of the maximum hoop stress location on the parameters of the surface loading (degree of asymmetry, size of loaded area) and of the opening (the opening height) was studied. It was found that the absolute magnitude of the maximum hoop stress (for all possible surface loading locations) is developed at the roof points when the opening height/width ratio is relatively large or when the pressure loading area is relatively narrow (compared to the roof arch radius), and contrarily, when the opening height/width ratio is relatively small or when the surface pressure is applied to a relatively wide area, the absolute magnitude of the maximum hoop stress is developed at the bottom sharp corner points.

A Study on the Cremation Status by the Jurisdiction Area and Outside of the Jurisdiction Area Using the E-Haneul Funeral Information System of Public Cremation Facilities in Gyeonggi-do : Focusing on Before and After the Opening of Public Cremation Facilities in Hwaseong City

  • Choi, Jae Sil;Nam, Yun Ju
    • International journal of advanced smart convergence
    • /
    • 제11권4호
    • /
    • pp.193-205
    • /
    • 2022
  • Based on the results of this study, we presented the following policy recommendations to improve the efficiency of operation and management of public cremation facilities. First, we findings the cremation number of all public cremation facilities in Gyeonggi-do increased from 39,918 people before the opening of public cremation facilities in Hwaseong to 55,642 people after the opening, showing a high rate of increase of 15,724 people(39.4%). Therefore, in order to increase the cremation ratio, the policy of expanding the supply of public cremation facilities should be actively pursued. Second, in this study we compared to before the opening of public cremation facilities in Hwaseong City, the ratio of cremation number the jurisdiction area of all public cremation facilities in Gyeonggi-do using the E-Haneul Funeral Information System increased by 19.0% from 35.9% to 54.9% after the opening, whereas it was analyzed that the outside of the jurisdiction area decreased by 19.0% from 64.1% to 45.1%. Therefore, in order to improve the convenience of citizens using the jurisdiction area, priority should be given to the promotion of policies for the establishment of public cremation facilities by local governments that do not have public cremation facilities. Third, through we research it is analyzed that the cremation ratio of the jurisdiction area of the public cremation facilities in Hwaseong City, which was jointly installed by six local governments located in Gyeonggi-do, was 92.4%, indicating that the ratio proportion of cremation number in the area is very high. Therefore, in order to improve the efficiency of the operation of public cremation facilities, the promotion of policies for joint installation and operation of public cremation facilities should be encouraged.

성형 Polyethylene의 연소성에 관한 연구 (A Study on the Combustability of Formed Polyethylene)

  • 정국삼;류영순
    • 한국안전학회지
    • /
    • 제9권3호
    • /
    • pp.60-66
    • /
    • 1994
  • The purpose of this study is to compare the combustability of the formed high density polyethylene (HDPE) with the low density polyethlyene(LDPE). That is, the easiness of ignition is examined by using the methods with Oxygen Index(OI) Tester and ventilation parameter, and the combustion velocity of these polyethylenes is measured by changing the size and shape of opening area. As the result of it, the oxygen index of HDPE, in a ignition, is required more than LDPE. Then, the concentration distribution of CO by combustion is increased when the opening area is small, but, in the same opening area, LDPE tends to increase more than HDPE. In addition, as the ratio of height to width of opening area is increased, combustion velocity becomes faster relatively. In consequence, when it is generally considered, the combustability of LDPE is better than HDPE.

  • PDF

국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구 (A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea)

  • 이규민;구태윤;황의청;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구 (A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System)

  • 오원신;정석환
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

스크린 망사의 견장과 오프닝의 변화 (The Opening Size Change for Screen Tension)

  • 정기영;강영립
    • 한국인쇄학회지
    • /
    • 제28권1호
    • /
    • pp.43-50
    • /
    • 2010
  • The 200mesh screen was tensioned and fixed on a frame. When applied tension to 5N and 10N per unit area, a side length of opening of the screen was 163.223${\mu}m$ and 168.224${\mu}m$, respective. But side length not tensioned was 158.879${\mu}m$. We knew that a side length of opening of the screen rarely changes with tension applied to the screen. The appearances that a side length of opening of the screen expand little are due to a decreasing diameter of thread by means of tension. In a thickness measurement of screen, While the high density mesh screen that had a lot of knots that crossed a line of latitude and longitude per unit area appeared a higher numerical value, the low density mesh screen that had a few knots appeared a low numerical value.