• Title/Summary/Keyword: Opening Pressure

Search Result 637, Processing Time 0.033 seconds

Effect of a surface oxide-dispersion-strengthened layer on mechanical strength of zircaloy-4 tubes

  • Jung, Yang-Il;Park, Dong-Jun;Park, Jung-Hwan;Kim, Hyun-Gil;Yang, Jae-Ho;Koo, Yang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.2
    • /
    • pp.218-222
    • /
    • 2018
  • An oxide-dispersion-strengthened (ODS) layer was formed on Zircaloy-4 tubes by a laser beam scanning process to increase mechanical strength. Laser beam was used to scan the yttrium oxide ($Y_2O_3$)-coated Zircaloy-4 tube to induce the penetration of $Y_2O_3$ particles into Zircaloy-4. Laser surface treatment resulted in the formation of an ODS layer as well as microstructural phase transformation at the surface of the tube. The mechanical strength of Zircaloy-4 increased with the formation of the ODS layer. The ring-tensile strength of Zircaloy-4 increased from 790 to 870 MPa at room temperature, from 500 to 575 MPa at $380^{\circ}C$, and from 385 to 470 MPa at $500^{\circ}C$. Strengthening became more effective as the test temperature increased. It was noted that brittle fracture occurred at room temperature, which was not observed at elevated temperatures. Resistance to dynamic high-temperature bursting improved. The burst temperature increased from 760 to $830^{\circ}C$ at a heating rate of $5^{\circ}C/s$ and internal pressure of 8.3 MPa. The burst opening was also smaller than those in fresh Zircaloy-4 tubes. This method is expected to enhance the safety of Zr fuel cladding tubes owing to the improvement of their mechanical properties.

Fabrication of silicon field emitter array using chemical-mechanical-polishing process (기계-화학적 연마 공정을 이용한 실리콘 전계방출 어레이의 제작)

  • 이진호;송윤호;강승열;이상윤;조경의
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.88-93
    • /
    • 1998
  • The fabrication process and emission characteristics of gated silicon field emitter arrays(FEAs) using chemical-mechanical-polishing (CMP) method are described. Novel fabrication techniques consisting of two-step dry etching with oxidation of silicon and CMP processes were developed for the formation of sharp tips and clear-cut edged gate electrodes, respectively. The gate height and aperture could be easily controlled by varying the polishing time and pressure in the CMP process. We obtained silicon FEAs having self-aligned and clear-cut edged gate electrode opening by eliminating the dishing problem during the CMP process with an oxide mask layer. The tip height of the finally fabricated FEAs was about 1.1 $\mu$m and the end radius of the tips was smaller than 100 $\AA$. The emission current meaured from the fabricated 2809 tips array was about 31 $\mu$A at a gate voltage of 80 V.

  • PDF

Influence of SKP 450, a $K^+$ Channel Opener, on the Pressor Actions Induced by Norepinephrine, Angiotensin II and Carotid Artery Occlusion in Rats (Norepinephrine, Angiotensin II 및 경동맥 폐쇄에 의한 혈압 상승작용에 대한 $K^+$ Channel 개방제인 SKP 450의 영향)

  • 고석태
    • Biomolecules & Therapeutics
    • /
    • v.9 no.2
    • /
    • pp.96-103
    • /
    • 2001
  • These studies were investigated about influence of SKP 450, a $K^{+}$ channel opener, on the pressor actions induced by norepinephrine, angiotensin II and carotid artery occlusion in rats. Before these studies, effect of SKP 450 itself on blood pressure was examinated. SKP 450 produced the depressor action in proportionaly to dose of 0.3, 1.0 and 3.0 $\mu$g/kg given intravenously and this depressor action was weakened by pretreatment of glibenclamide, a $K^{+}$ channel blocker. The pressor action induced by norepinephrine, an alpha-adrenergic agonist, was blocked 1 hr after administation of SKP 450 in a dose of 3.0 $\mu\textrm{g}$/kg, i.v. and directly after in a dose of 6.0 $\mu\textrm{g}$/kg, i.v.. The pressor action induced by angiotensin II was blocked immediatly after treatment of SKP 450 in a dose of 3.0 $\mu\textrm{g}$/kg, i.v.. The pressor action caused by carotid artery occlusion was not affected by SKP 450 of 3.0 $\mu\textrm{g}$/kg, i.v., whereas markedly blocked by SKP 450 of 6.0 $\mu\textrm{g}$/㎦, i.v.. The potentiated-pressor actions of norepinephrine and angiotensin II by pretreatment of chlorisondamine, a autonomic ganglionic blocking agent, were also blocked by administration of SKP 450 in a dose of 6.0 $\mu\textrm{g}$/kg, i.v.. The weakened-pressor action of carotid artery occlusion by pretreatment of chlorisondamine was more weakened by SKP 450 6.0 $\mu\textrm{g}$/kg, i.v.. The results suggest that hyperpolarization formed through $K^{+}$ channel opening in cell membrane inhibits the pressor action induced norepinephrine ; angiotensin II ; and carotid artery occlusion.usion.

  • PDF

Implant overdenture with closed impression technique for patient with Myasthenia Gravis: A case report (중증 근무력증 환자에서 폐구 인상법을 이용한 임플란트 피개의치 수복 증례)

  • Park, Lydia;Park, Minhyuk;Park, Sangwon;Lim, Hyun-Pil;Jang, Woohyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.459-468
    • /
    • 2021
  • In patients with myasthenia gravis, it is difficult to manufacture and maintain dentures because the muscles and nervous system in the oral cavity are not properly adjusted. In addition, excessively extended or thick dentures may cause muscle weakness by stimulating the muscles, so dentures should be manufactured in consideration of this. In this case, a denture was fabricated using the closed mouth technique in a patient with myasthenia gravis with mouth opening limitation. Using the closed mouth technique, the patient's masticatory pressure and muscle movements were reproduced and denture with good retention were manufactured.

Analysis of Smoke Behavior in Fire within Real-scale Theater Using FDS: Influences of Fire Curtain and Natural Smoke Vent Area (FDS를 이용한 실규모 공연장 무대 내 화재 시 연기 거동 분석: 방화막 및 자연배출구 면적의 영향)

  • Kim, Jae Han;Lee, Chi Young;Jeong, Lee Gyu;Kim, Duncan
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.7-14
    • /
    • 2018
  • This study investigated numerically the influences of fire curtain and natural smoke vent area on smoke movement in the stage fire of a theater using FDS (Fire Dynamics Simulator). The dimension of the theater stage was 31 m in width, 34 m in depth, and 32 m in height. The area ratios between the natural smoke vent and stage were approximately 10%, 8%, 5%, and 1%. The gap distance between the fire curtain and proscenium wall was 0.5 m. The fire curtain and natural smoke vent area were observed to affect significantly the behavior of smoke movement to the auditorium and the mass flow rates of inflow and outflow through the natural smoke vent and proscenium opening. In addition, under the same natural smoke vent area, the pressure in the stage with a fire curtain was lower than that without a fire curtain.

3D Numerical investigation of a rounded corner square cylinder for supercritical flows

  • Vishwanath, Nivedan;Saravanakumar, Aditya K.;Dwivedi, Kush;Murthy, Kalluri R.C.;Gurugubelli, Pardha S.;Rajasekharan, Sabareesh G.
    • Wind and Structures
    • /
    • v.35 no.1
    • /
    • pp.55-66
    • /
    • 2022
  • Tall buildings are often subjected to steady and unsteady forces due to external wind flows. Measurement and mitigation of these forces becomes critical to structural design in engineering applications. Over the last few decades, many approaches such as modification of the external geometry of structures have been investigated to mitigate wind-induced load. One such proven geometric modification involved the rounding of sharp corners. In this work, we systematically analyze the impact of rounded corner radii on the reducing the flow-induced loading on a square cylinder. We perform 3-Dimensional (3D) simulations for high Reynolds number flows (Re=1 × 105) which are more likely to be encountered in practical applications. An Improved Delayed Detached Eddy Simulation (IDDES) method capable of capturing flow accurately at large Reynolds numbers is employed in this study. The IDDES formulation uses a k-ω Shear Stress Transport (SST) model for near-wall modelling that prevents mesh-induced separation of the boundary layer. The effects of these corner modifications are analyzed in terms of the resulting variations in the mean and fluctuating components of the aerodynamic forces compared to a square cylinder with no geometric changes. Plots of the angular distribution of the mean and fluctuating coefficient of pressure along the square cylinder's surface illustrate the effects of corner modifications on the different parts of the cylinder. The windward corner's separation angle was observed to decrease with an increase in radius, resulting in a narrower and longer recirculation region. Furthermore, with an increase in radius, a reduction in the fluctuating lift, mean drag, and fluctuating drag coefficients has been observed.

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

  • Su An Kim;Jaeho Shim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • Background: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. Objectives: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. Methods: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. Results: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 ㎛, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 ㎛, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 ㎛ with a 95% LoA span of 1,110.95 ㎛, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. Conclusions: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Correlation Among the Cervical Kyphotic Angle, Pain, and Disability Level in Patients With Temporomandibular Disorders (턱관절장애 환자의 목뼈 뒤굽음 각과 통증 및 기능장애 수준 간에 상관성 연구)

  • Lee, In-su;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.102-110
    • /
    • 2020
  • Background: There is an opinion that improper postures of the head and cervical spine are associated with temporomandibular joint (TMJ) disorders (TMDs). Objects: The aim of this study was to investigate the proportions among the cervical kyphotic angle, physical symptoms including the pain intensity level of the TMJ, and severity of TMD disability in patients diagnosed with TMD. Methods: Sixty-two subjects participated in the study. The evaluation tools included measurements of the cervical kyphotic angle based on the Ishihara index, pressure pain threshold (PPT) on the TMJ, maximal mouth opening (MMO) without pain, current pain intensity level of the TMJ measured using the Quadruple Visual Analogue Scale (QVAS), Korean TMD (KTMD) disability index, KTMD Symptom Frequency/Intensity Scales (SFS/SIS), and Korean Headache Impact Test-6. Correlation analysis was conducted to investigate the correlations between the cervical kyphotic angle and parameters related to TMJ symptoms. Results: Variables that were significantly correlated with the cervical kyphotic angle were the PPT around the TMJ (r = 0.259, p < 0.05), current pain intensity level of the TMJ based on the QVAS (r = -0.601, p< 0.01), and usual pain intensity level based on the SIS (r = -0.379, p < 0.01). The level of TMD functional disability was significantly correlated with the degree of headache (r = 0.551, p < 0.01), level of PPT of the TMJ (r = -0.383, p < 0.01), pain-free MMO (r = -0.515, p < 0.01), pain intensity level of the TMJ based on the QVAS (r = 0.393, p < 0.01), TMD symptom frequency (r = 0.739, p < 0.01), usual pain intensity of the TMJ (r = 0.624, p < 0.01), and most severe pain intensity of the TMJ (r = 0.757, p < 0.01). Conclusion: There is a positive correlation between the cervical kyphotic angle and PPT and a negative correlation between the current and usual pain intensity levels of the TMJ. The cervical kyphotic angle was a predictor of the pain level, tenderness threshold, and intensity of pain in the TMJ.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.