• Title/Summary/Keyword: Opening Pressure

Search Result 637, Processing Time 0.028 seconds

Development of Postdural Puncture Headache Following Therapeutic Acupuncture Using a Long Acupuncture Needle

  • Jo, Dae-Jean;Lee, Bong-Jae;Sung, Joon-Kyung;Yi, Jae-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.140-142
    • /
    • 2010
  • Acupuncture appears to be a clinically effective treatment for acute and chronic pain. A considerable amount of research has been conducted to evaluate the role that acupuncture plays in pain suppression; however, few studies have been conducted to evaluate the side effects of the acupuncture procedure. This case report describes a suspected postdural puncture headache following acupuncture for lower back pain. Considering the high opening pressure, cerebrospinal fluid leakage, and the patient's history of acupuncture in the lower back area, our diagnosis was iatrogenic postdural puncture headache. Full relief of the headache was achieved after administration of an epidural blood patch.

A realization of simulator for reliability verification on medium size steam turbine controller (중용량 증기터빈 제어기의 신뢰성 검증을 위한 시뮬레이터 구현)

  • Choi, I.K.;Woo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2578-2580
    • /
    • 2000
  • A siumlator had been developed and used for reliability verification on medium size steam turbine control programs prior to its actual operation in field. A mathematical model on thermal dynamics pertaining to prime mover steam turbine and electrical generator was realized and included in this simulator. Also, many operating data acquired from fields was utilized in order to decide mechanical and thermal dynamic characteristics such as friction loss, windage loss and inertia. A user can decide closing or opening velocity of steam stop valve and steam regulation valve. This simulator is able to generate steam pressure, turbine speed, electrical power, and power system frequency.

  • PDF

Stabilization of Fuel F1ow in a Multi-Nozzle Combustion System Burning Natural Gas (천연가스 다노즐 열원설비의 연료 유동 안정화)

  • 박의철;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1255-1265
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient flow in a utility gas turbine burning natural gas. The solution domain encompasses the supply gas pressure regulator to the combustor of the gas turbine that employs multi-nozzle fuel injectors. Some results produced for verification in the present study agree suite well with the experimental ones. It is found that the total gas flow may decrease noticeably during its combustion mode change, which would be the reason of momentary combustion upset, when a reference case of opening ratios of control valves in the system is applied. Several parameters are then varied in order to make the total gas flow stable over that period of time. Results of this study may be useful to understand the unsteady behavior of combustion system burning natural gas.

  • PDF

Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane Microvalve (열공압 방식의 Polydimethylsiloxane 마이크로 밸브의 제작 및 특성)

  • 김진호;조주현;한경희;김영호;김한수;김용상
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • A normally open thermopneumaticc-actuated microvalve has been fabricated and their properties are investigated. The advantages of the proposed microvalve are of the low cost fabrication process and the transparent optical property using polydimethylsiloxane (PDMS) and indium tin oxide (ITO) glass. The fabricated microvalves with in-channel configuration are easily integrated with other microfluidic devices on the same substrate. The fabrication process of thermopneumatic-actuated microvalvesusing PDMS is very simple and its performance is very suitable for a disposable lab-on-a-chip. The PDMS membrane deflection increases and the flow rates of the microchannel with microvalvels decrease as the applied power to the ITO heater increases. The powers at flow-off are dependent on the membrane thickness and the applied inlet pressure but are independent of the channel width of microvalves. The flow rate is well controlled by the switching function of ITO heater and the closing/opening times are around 20 sec and 25 sec, respectively.

A realization of simulator for reliability verification on large steam turbine controller (대용량 증기터빈 제어기의 신뢰성 검증을 위한 시뮬레이터 구현)

  • Choi, I.K.;Jeong, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2138-2140
    • /
    • 2001
  • A siumlator had been developed and will be used for reliability verification on large steam turbine control programs prior to its actual operation in field. A mathematical model on thermal dynamics pertaining to prime mover steam turbine and electrical generator was realized and included in this simulator. Also, many operating data acquired from fields was utilized in order to decide mechanical and thermal dynamic characteristics such as friction loss, windage loss and inertia. A user can decide closing or opening velocity of steam stop valves and steam regulation valves. This simulator is able to generate steam pressure, turbine speed, electrical power, and power system frequency.

  • PDF

A Study on Development 9f Rotary Valve for Performance Enhancement in SI Engine (스파크점화 기관의 성능향상을 위한 회전형 흡배기장치의 개발에 관한 연구)

  • 김치원;윤창식;김유식
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.11-20
    • /
    • 1995
  • In recent years, the study on the high efficiency of the internal combustion engine has been mainly proceeding. In this study, we developed rotary valve to achieve the improvement of volumetric efficiency and to be simple construction. And then made a comparative analysis between rotary and poppet valve. In this experiment, rotary valve enlarged the flow area of valve port to minimize the resistance of the fluid flow and to flow smoothly in intake and exhaust process. Indeed, valve timing was controlled properly lest positive pressure in exhaust process should affect intake process. Motoring and firing experiments were using engine speed and air-fuel ratio as the principle parameter and the full opening of throttle valve and minimum spark advance for best torque (MBT) as engine operating variables.

  • PDF

Synthesis Peculiarities of Nanocomposite Structures by Abrasive-reaction Interactions

  • Ketegenov, T.;Tyumentseva, O.;Kasymbecova, D.;Korobova, N.;Katranova, Z.;Urakaev, F.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.643-644
    • /
    • 2005
  • New methods of nano-sized material and composite coating preparations have been considered on the base of mathematical model of abrasion-reaction interaction of milling and grinding bodies in planetary centrifugal mill. The essence of the method is the abrasive and oxidative wear of the milling bodies and amorphous (better inert) additives. Interactions between them has been supplied the necessary impulse of pressure and temperature on the impact-frictional contacts and promoted chemical processes. The offered method can find application for such processing as sintering and geological minerals opening.

  • PDF

Surgical Treatment of Budd-Chiari Syndrome -1 Cases Report- (Budd-Chiari Syndrome 수술치험 -1례 보고-)

  • 조은희
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.710-713
    • /
    • 1994
  • The Budd-Chiari syndrome is a rare type of portal hypertension caused by complete or incomplete obstruction of the hepatic vein or the corresponding portion of the inferior vena cava or both. In this case, the obstruction was located just beneath the diaphragm, above the right hepatic vein opening, which was confirmed by vena cavography preoperatively. Budd-Chiari syndrome with stenosis or thrombosis of the inferior vena cava may be cured by prosthetic bypass to the right atrium. This case is caused by thrombus of unknowed primary origin. Combined mesoatrial and cavoatrial shunt should be encouraged in this specific situation. Postoperatively, there were marked fall of venous pressure and symptoms and signs improved remarkably.

  • PDF

Gas Flow Pattern Through a Long Round Tube of a Gas Fueling System (II) (기체연료주입계의 긴 원형도관에서 기체 흐름의 유형 (2))

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.594-604
    • /
    • 2006
  • Gas fueling systems operated in the mode of a fixed valve opening at a constant line pressure, and the mode of a constant inlet flow are simulated to establish the relationships between the gas flow pattern and the tube dimensions under various system conditions.

울진 3,4호기의 가압기고압력 원자로정지여유도 민감도 분석

  • 손석훈;서호택;정원상;서종태;이상근
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.594-601
    • /
    • 1996
  • 가압기고압력 원자로정지여유도(high pressurizer pressure trip margin)에 영향을 주는 요인들에 대한 민감도 분석을 울진 3,4호기 성능해석코드인 LTCUCN computer code틀 이용하여 수행하였다. 그 결과, 초기 가압기압력, 증기우회제어계통의 quick open지연시간, 터빈우회밸브의 quick opening시간, 원자로출력 감발계통의 용량, 원자로출력감발 제어붕 낙하시간, 가압기 살수작동 설정치 둥이 완전부하상실시 가압기압력을 상승시키는 주요인자임을 알 수 있었으며, 증기우회제어계통 및 가압기살수계통의 용량은 최대 가압기 압력에 미치는 영향이 미미한 것으로 판명되었다. 울진 3,4호기의 참조발전소인 영광 3,4호기의 as-built 자료를 토대로 울진 3,4호기의 원자로정지여유도를 계산한 결과 울진 3,4호기는 완전부하상실사건시 37 psi의 정지여유도를 가질 수 있는 것으로 판단된다. 그러나, 원자로출력감발계통이 있는 ABB-CE type의 울진 3,4호기에서는 완전부하상실사건보다 원자로출력감발계통이 동작하지 않는 부하감발사건이 최대 가압기 압력치를 유발하는 사건이고, 다양한 부하상실사건중에도 운전여유도는 확보하고 있음을 알 수 있었다.

  • PDF