• Title/Summary/Keyword: Opening Pressure

Search Result 637, Processing Time 0.028 seconds

Structural Capability Evaluation of the Conventional and Pilot Type Valves for LNG/LNG-FPSO Ships (LNG/LNG-FPSO 선박용 컨벤셔널 및 파일럿 타입 밸브의 구조성능평가)

  • Hwang, Dong Wook;Kim, Sung Jin;Bae, Jun Ho;Jung, Sung Yuen;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.12
    • /
    • pp.1331-1339
    • /
    • 2012
  • Safety valve used in LNG/LNG-FPSO ships is a high value valve, and it plays an important role in maintaining a fixed level of pressure by emitting LNG gas out of pipes in LNG piping system under the cryogenic and high-pressure condition when the pressure of the system connected with the LNG storage tank and pipes reaches over the set pressure. The structural stability is required for the inner pressure and thermal load because of the cryogenic and high-pressure condition, and a reliability of the safety valve is necessary for impact and deformation by opening the valve. But, the safety valve, which plays a key role for a safety of the transport and storage system, is depended on imports for over 90%, and in domestic production, the design of the valve is performed on the basis of experiences of the works without quantitative analysis for the inner operation characteristics and structural stability of the valve. In this study, impact velocity is calculated by theoretical analysis for obtaining the structural stability of the guide according to the impact load by opening the valve. The shape of the guide and the diaphragm for satisfying the structural stability are suggested and verified by using a thermal-structural analysis.

An Experimental Study on the Spray Characteristics by Twin-Fluid Atomizer for Wide Band Spray (광폭면 분무를 위한 2유체 노즐의 분무 특성에 관한 연구)

  • Lee, Joong-Soon
    • Journal of ILASS-Korea
    • /
    • v.13 no.4
    • /
    • pp.212-219
    • /
    • 2008
  • To develop the twin-fluid atomizer having the excellent performance of painting, the spray characteristics of how a wide area can be painted efficiently by one time spraying were studied in this paper. Spray phenomena are affected by the many factors determining the spray field such as the spraying pressure of gas, the spraying pressure and viscosity of liquid paints, the opening duration of needle valve, the design dimension of nozzle, and so on. As the results of experiments, these factors affecting on spray characteristics were suggested as followings; 1) The optimum spraying pressure of gas was $0.015{\sim}0.02\;kPa$, and the appropriate spraying pressure of liquid paint was 0.01kPa, In these situations, the setting up pressures must be compensated as much as the losing amount of pressure because a decompression occurred when operating valves. 2) The duration of opening the needle valve must be sustained for $1{\sim}2$ seconds to inject gas after spraying the liquid paint. This operating of the needle valve was necessary to avoid the affect on the changing of liquid column length, and to prevent the droplet deposit at the initial time of spraying. 3) The spray tip penetration was gained form the experimental equation, and the effective spraying angle was $85^{\circ}{\pm}5^{\circ}$ just at he appropriate spraying pressure of gas. The distribution of the area sprayed had the variation in $350{\pm}50\;mm$ because of the spraying pressure of gas, the its distance from the spray tip, and the lift of the needle valve.

  • PDF

Pressure Differentials in the Elevator Lobby Depending on the Evacuation Scenarios (피난 시나리오에 따른 승강장 부속실 차압 특성 연구)

  • Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • The aim of this paper is to investigate the change of pressure differential and smoke propagation characteristics in the elevator lobby with the resident's evacuation scenarios using fire modelling technique. The results showed absolute pressures in the fire room and elevator lobby can significantly increase to cause fire door to the stairway unclosed once it is open. This is due to constant pressure differentials, the increasing reference pressure of fire lobby and pressure leak from elevator lobby to fire lobby. Smoke exhaust mechanism was needed to prevent the continuous pressure rise in the living room. Over 200 Pa was expected upon closing the door during pressurization, which provide difficulties in opening the door for next refugee. Opening both fire door and entrance door may induce smoke flow from fire room to elevator lobby and stairway.

An Aerodynamic Study of Velopharyngeal Closure Function in Cleft Palate Patients (구개열 환자의 비인강폐쇄 기능에 대한 공기역학적 연구)

  • Ahn, Tae-Sub;Yang, Sang-Ill;Shin, Hyo-Keun
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.237-259
    • /
    • 1997
  • Cleft Palate speech appears to have hyper/hyponasality with velopharyngeal insufficiency and articulation disorders. Previous studies on Cleft Palate speech have shown that speech tends to have lower airflow and air pressure. To examine the aerodynamic characteristics of Cleft Palate speech, Aerophone II Voice function Analyzer was used. We measured sound pressure level, airflow, air pressure and glottal power. Three Cleft Palate adults and five normal adults participated in this experiment. The test words are composed of: (1) the sustained vowel /o/ (2) /CiCi/, where C is one of three different stop consonants in Korean (3) /bimi/. Subjects were asked to produce /bimi/ five times without opening their lips. All the data was statistically tested by t-test for Cleft Palate patients before operation groups and control groups and paired t-test for Cleft Palate patients before and after operation groups. The results were as follow: (1) Cleft Palate patients generally speak with incomplete oral closure and lower oral air pressure. As a result, the SPL of Cleft Palate before operation is 3 dB lower than control groups. (2) Airflow of Cleft Palate in phonation and articulation is lower than that of control groups. However, it increased after operation. Lung volume and mean airflow in phonation are significantly increased (p<0.05). (3) Although velopharyngeal function (velar opening rate) of Cleft Palate is poor in comparison with control groups, it was recovered after operation. In this event maximum flow rate and mean airflow rate are significantly increased (p<0.05). (4) Air pressure of Cleft Palate in speech is lower than that of control groups. In general, the air pressure of Cleft Palate increased after operation. In this event air pressure of glottalized consonant is significantly increased (p<0.04). (5) Glottal Power(mean power, mean efficient and mean resistant) of Cleft Palate patients is lower than that of control groups. But mean efficient and mean resistant of Cleft Palate patients increased significantly (p<0.05) after operation.

  • PDF

An Effect of Pressure and Temperature on Spray Characteristic (분무특성에 미치는 압력.온도의 영향)

  • Oh, Eun-Tak;Ryu, Ho-Sung;Ahn, Byoung-Kyu;Song, Kyu-Keun;Jung, Jae-Youn
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.946-951
    • /
    • 2001
  • This experimental study is to investigate the intermittent spray characteristics of a pintle nozzle. High speed camera used in this expreiment with 9000fps. The factor, which controls the diesel spray, is the Injection pressure, ambient pressure and ambient temperature. In this paper, experiments were conducted free spray for the ambient pressure(3, 4, 5Mpa), nozzle Injection pressure(10, 14, 18MPa) and ambient temperature(293, 473K). With the higher opening pressure, the spray tip velocity and spray penetration increases while the spray angle decreases, On the other hand, With the higher ambient pressure, the spray angle increase while the spray tip penetration and spray tip velocity decrease. also, With the higher ambient temperature, the spray penetration decrease while the spray angle decrease.

  • PDF

Gravity-Injection Core Cooling After a Loss-of-SDC Event n the YGN Units 3 & 4

  • Seul, Kwang-Woo;Bang, Young-Seok;Kim, Hho-Jung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.476-485
    • /
    • 1999
  • In order to evaluate the gravity-injection capability to maintain core cooling after a loss-of-shutdown-cooling event during shutdown operation, the plant conditions of the Yong Gwang Units 3&4 were reviewed. The six cases of possible gravity-injection paths from the refueling water tank (RWT) were identified and the thermal-hydraulic analyses were performed using the RELAP5/MOD3.2 code. The core cooling capability was significantly dependent on the gravity-injection path, the RCS opening, and the injection rate. In the cases with the pressurizer manway opening higher than the RWT water level, the coolant was held up in the pressurizer and the system pressure continued increasing after gravity-injection. The gravity injection eventually stopped due to the high system pressure and the core was uncovered. In the cases with the injection path and opening on the same leg side, the core cooling was dependent on whether the water injected from the RWT passed the core region or not. However, in the cases with the injection path and opening on the different leg side, the system was well depressurized after gravity-injection and the core boiling was successfully prevented for a long-term transient. In addition, from the sensitivity study on the gravity-injection flow rate, it was found that about 54 kg/s of injection rate was required to maintain the core cooling and the core cooling could be provided for about 10.6 hours after event with that injection rate from the RWT. Those analysis results would provide useful information to operators coping with the event.

  • PDF

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

Development of DME Engine Using 3.9 Liter Diesel Engine with Mechanical Type Fuel System (3.9 리터 기계식 디젤 엔진을 이용한 DME 엔진 개발 연구)

  • JANG, JINYOUNG;WOO, YOUNGMIN;KIM, GANGCHUL;CHO, CHONGPYO;JUNG, YONGIN;KO, AHYUN;PYO, YOUNGDUG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.3
    • /
    • pp.307-313
    • /
    • 2020
  • The 3.9 liter diesel engine with a mechanical fuel injection system was converted to di-methyl ether (DME) engine and performance optimized. In order to switch to the DME engine, the plunger of the high pressure fuel pump was replaced and the diameter of the injector nozzle was increased. Through this, the disadvantage of DME having low calorific value per volume can be compensated. To optimize the performance, the number of injector nozzle holes, injector opening pressure, and fuel injection timing were changed. As a result, the optimum number of injector nozzle holes was 5, the injector opening pressure was from 15 MPa to 18 MPa, and the injection timing was 15 crank angle degree before top dead center (CAD BTDC). The power was at the same level as the base diesel engine and nitrogen oxides (NOx) emissions could be reduced.

A FLUID TRANSIENT ANALYSIS ON THE PIPE NETWORK OF BIPROPELLANT PROPULSION SYSTEM WITH AN UNSTEADY FRICTION (이원추진제 추진시스템의 배관망에 대한 비정상 마찰을 고려한 과도기유체 해석)

  • Chae, Jong-Won;Han, Cho-Young;Kim, Jung-Hoon;Jun, Hyoung-Yoll
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.487-490
    • /
    • 2010
  • A fluid transient analysis on the pipe network of bipropellant propulsion system is conducted through numerical parametric studies in which unsteady friction results are compared with quasi-steady friction results and also show the pressure drop results during the liquid apogee engine firing. The fluid transient analysis program has verified through comparing with the original Zielke model, the full and recursive convolution model and quasi-steady model as a reference. And the pressure drop program also has verified through comparing with results of the well-known program, EPANET2. The bipropellant propulsion system has two different fluids as fuel and oxidizer, and mostly they are hypergolic combination so that the valve opening and closing of the thrusters, that cause the pressure waves, shall take place simultaneously to get proper performance. The different physical properties of the fuel and oxidizer result in the different responsive to the same valve opening and closing. The response results may be helpful to know the characteristics of the bipropellant propulsion system and design it.

  • PDF