Arc Phenomena and Induced Voltage due to Inductive Energy of Superconducting Coil (초전도 코일의 유도성 에너지에 의한 아크현상과 유기 과전압)

  • 최병주;류경우;성기철;김해종
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.24-30
    • /
    • 2000
  • This paper present the characteristics of the internal induced voltage and arc phenomena in liquid helium at the energy transfer from a superconducting magnet to a load resistor. Especially generation mechanism of the oscillated wave from of the coil terminal voltage is analyzed by considering circuit constant of the superconducting magnet, load condition and arc resistance of the mechanical opening switch. The wavefront and peak portion of the voltage are strongly influenced by arc discharge triggered by the switch separation in liquid helium. Abrupt arc extinction leads to voltage oscillation with an enormous peak. It is suggested that the superconducting magnet should be designed to ensure the internal surge when arc is possibly formed by switch opening or coil short circuit between turns or layers. Finally, a suppression method of the oscillating surge is proposed based on the load condition.

  • PDF

Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator (스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

Analysis on interaction of Ground and support using Ground response curve for tunnel design (지반응답곡선을 이용한 지반과 지보재의 상호작용 분석)

  • Ahn, Tae-Hun;Ahn, Sung-Hak;Lee, Song
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1059-1064
    • /
    • 2002
  • The behavior of an opening and the performance of support system depend upon the load-deformation characteristics of ground and support as well as of the manner and of timing of support installation. The load-deformation characteristics of ground and support are derived by the interaction between ground and support. The interaction between ground and support is qualitatively illustrated by a ground response curve. The behavior of an opening and the performance of support system depend upon the load-deformation characteristics of ground and support as well as of the manner and of timing of support installation. The interaction between ground and support is qualitatively illustrated by a ground response curve. The convergence-confinement method don't need the basic assumptions for a mathematical model. Also This is applicable to general tunnel. Consequently the stability of tunnel must be qualitatively investigated by a ground response curve and quantitatively adjudged by a numerical analysis for the reasonable design of tunnel.

  • PDF

Effect of local web buckling on the cyclic behavior of reduced web beam sections (RWBS)

  • Akrami, Vahid;Erfani, Saeed
    • Steel and Composite Structures
    • /
    • v.18 no.3
    • /
    • pp.641-657
    • /
    • 2015
  • Application of reduced web beam section (RWBS) as a sacrificial fuse element has become a popular research field in recent years. Weakening of beam web in these connections may cause local web buckling around the opening area which can affect cyclic behavior of connection including: maximum load carrying capacity, strength degradation rate, dissipated energy, rotation capacity, etc. In this research, effect of local web buckling on the cyclic behavior of RWBS connections is investigated using finite element modeling (FEM). For this purpose, a T-shaped moment connection which has been tested under cyclic loading by another author is used as the reference model. Fracture initiation in models is simulated using Cyclic Void Growth Model (CVGM) which is based on micro-void growth and coalescence. Included in the results are: effect of opening corner radii, opening dimensions, beam web thickness and opening reinforcement. Based on the results, local web buckling around the opening area plays a significant role on the cyclic behavior of connection and hence any parameter affecting the local web buckling will affect entire connection behavior.

Assistant Model For Considering Slot-Opening Effect on No-load Air-gap Flux Density Distribution in Interior-type Permanent Magnet Motor (매입형 영구자석 전동기에서 무부하시 공극 자속밀도 분포에 대한 Slot-Opening Effect를 고려한 보조 모델)

  • Fang, Liang;Kim, Do-Jin;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.759-765
    • /
    • 2011
  • This paper proposes an effective assistant model for considering the stator slot-opening effect on air gap flux density distribution in conventional interior-type permanent magnet (IPM) motor. Different from the conventional slot-opening effect analysis in surface-type PM (SPM) motor, a composite effect of slot-opening uniquely existing in IPM motor, which additionally causes enhancement of air gap flux density due to magnet flux path distortion in iron core between the buried PM and rotor surface. This phenomenon is represented by a proposed assistant model, which simply deals with this additional effect by modifying magnetic pole-arc using an effective method. The validity of this proposed analytical model is applied to predict the air gap flux density distribution in an IPM motor model and confirmed by finite element method (FEM).

A Study on Fatigue Crack Growth Characterization Of Surface Crack In Pressure Vessel Materials (압력용기 소재에서의 표면균열의 피로균열 성장특성에 관한 연구)

  • 허용학;이주진;한지원;김종집;문한규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.96-102
    • /
    • 1990
  • Cracks found in pressure vessels have been reported to be mostly semi-elliptic surface cracks. The fatigue crack growth behaviour of the surface cracks on pressure vessel materials, SPV 50Q and API 5A-K55, was studied with the consideration of the crack opening character. To determine the crack opening loads for the surface cracks, the displacement/strain were measured at three positions; the center and the side of the surface crack, the back face of the specimen using CMOD gauge and strain gauges. The experimental results showed that the crack opening load levels measured at the side of the surface crack were generally a little higher than those measured at the back face. As for the crack growth rates at the different parts of the surface crack, the experiments also showed that, if .DELTA.K$_{eff}$ is used, the exponent n of the Paris' law obtained were the same for the rear and the side parts of the surface cracks.

Numerical Study on Variations in the Sealing Performance of Air Curtains in Large-Scale Factory Opening Considering Various Design Factors (대형 공장 개구부용 에어커튼의 설계 인자에 따른 차단 성능 변화에 대한 전산해석 연구)

  • Moon, Jongmin;Rhee, Gwang Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.703-711
    • /
    • 2015
  • In large-scale factories, there are usually openings in the building to increase the efficiency of workers. However, if the factory is heated during winter, openings significantly increase the heating load. Therefore, there is a need for air curtains to be installed at the top of openings in factories to reduce the heating load due to the cold air entering from outside. The main design variables of these air curtains are the discharge angle, speed, and temperature, etc. While there have already been many studies focusing on these design variables, the distance from the opening and the width of the discharge have not been studied even though they also affect the sealing performance. As a result, when the distance from the opening decreases and the width of the discharge increases, we realize an optimum air curtain performance. However, if the distance from the opening is about 1.5 m, by adjusting the discharge angle and the distance from the opening, the sealing performance of the air curtain is improved by 13.7%.

Experimental and numerical investigation of reinforced concrete beams containing vertical openings

  • Parol, Jafarali;Ben-Nakhi, Ammar;Al-Sanad, Shaikha;Al-Qazweeni, Jamal;Al-Duaij, Hamad J.;Kamal, Hasan
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.383-393
    • /
    • 2019
  • Horizontal openings in reinforced concrete (RC) beams are quite often used to accommodate service pipelines. Several research papers are available in the literature describing their effect. RC beams with vertical openings are commonly used to accommodate service lines in residential buildings in Kuwait. However, there are lack of design guidelines and best practices reported in the literature for RC beams with vertical openings, whereas the detailed guidelines are available for beams with horizontal openings. In the present paper, laboratory experiments are conducted on nine RC beams with and without vertical openings. Parametric study has been carried out using nonlinear finite element analysis (FEA) with changes in the diameter of the opening, various positions of the opening along the length and width of the beam, edge distance, etc. 50 finite element simulations were conducted. The FEA results are verified using the results from the laboratory experiments. The study showed that the load carrying capacity of the beam is reduced by 20% for the RC beam with vertical openings placed near the center of the beam compared to a solid beam without an opening. Significant reduction in load carrying capacity is observed for beams with an opening near the support (${\approx}15%$). The overall stiffness of the beam, crack pattern and failure modes were not affected due to the presence of the vertical opening. Furthermore, an artificial neural network (ANN) analysis is carried out using the FEA generated data. The results and observations from the ANN and FEA are in good agreement with experimental results.

Effects of the location and size of web openings on shear behavior of clamped-clamped reinforced concrete beams

  • Ceyhun Aksoylu;Yasin Onuralp Ozkilic;Ibrahim Y. Hakeem;Ilker Kalkan
    • Computers and Concrete
    • /
    • v.33 no.3
    • /
    • pp.251-264
    • /
    • 2024
  • The present study pertains to the effects of variations in the location and size of drilled web openings on the behavior of fixed-fixed reinforced concrete (RC) beams. For this purpose, a reference bending beam with a transverse opening in each half span was tested to failure. Later, the same beam was modeled and analyzed with the help of finite element software using ABAQUS. Upon achieving close agreement between the experimental and numerical results, the location and size of the web opening were altered to uncover the effects of these factors on the shear strength and load-deflection behavior of RC beams. The experimental failure mode of the tested beam and the numerical results were also verified by theoretical calculations. In numerical analysis, when compared to the reference (D0) specimen, if the distance of the opening center from the support is 0 or h or 2h, reduction in load-bearing capacity of 1.5%-22.8% or 2.0%-11.3% or is 4.1%-40.7%. In other words, both the numerical analyses and theoretical calculations indicated that the beam behavior shifted from shear-controlled to flexure-controlled as the openings approached the supports. Furthermore, the deformation capacities, energy absorption values, and the ductilities of the beams with different opening diameters also increased with the decreasing distance of the opening from supports. Web compression failure was shown to be the predominant mode of failure of beams with large diameters due to the lack of sufficient material in the diagonal compression strut of the beam. The present study indicated that transverse openings with diameters, not exceeding about 1/3 of the entire beam depth, do not cause the premature shear failure of RC beams. Finally, shear damage should be prevented by placing special reinforcements in the areas where such gaps are opened.

A Study on the Fatigue Crack Propagation Behavior in the SB41 Welding Material (SB41용접재의 피로크랙 진전거동에 관한 연구)

  • 최병기;장경천
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.43-49
    • /
    • 2002
  • SB41 material is welded automatically and is investigated some effects of the welding residual stress in the growth and propagation of fatigue crack, so as to study the fatigue behaviour in the welding residual stress field. The summarized results are as follows; 1) In case of the load amplitude is constant, as the stress ratio is changing to 0.1, 0.33 and 0.5 the propagation life is constant but the growth life decreases. And than, when maximum load or minimum load is constant as the stress ratio increases the growth life and propagation life. 2) It was shown that fatigue crack propagation ratio da/dN was almost constant regardless of the stress ratio change at constant load amplitude and that the larger stress ratio, the slower was the fatigue crack propagation ratio. 3) The opening ratio U is influenced by $K_max$ but it isn't only the function of $K_max$ because data range is very large. 4) The fatigue life of the specimens on tensile compressive residual stress field was decreased and increased respectably more than that of the base metal.