• 제목/요약/키워드: Opening Load

검색결과 410건 처리시간 0.025초

제품 신뢰성 확보을 위한 배전 계통에 사용되는 전자개폐기 가속스트레스시험에 관한 연구 (To Ensure A Product Reliability The Study on Accelerated Stress Tests for Magnetic Switch Used in Power Distribution System)

  • 류행수;박상용;한규환;권영일;윤남식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.377-380
    • /
    • 2005
  • In this paper, accelerated stress test(AST) for Magnetic Switch (MS) are applied to assure specified reliability of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, AST for product assembly are developed in order to improve the weak point so that increase the product reliability. Also we will show the basic information for the accelerated life test(ALT). The proposed AST results and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in the world markets.

  • PDF

IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구 (The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch)

  • 류행수;김갑동;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF

배전선로에 사용되는 전자개폐기(Magnetic Switch)의 가속수명시험에 관한 연구 (A Study on Accelerated Life Tests for Magnetic Switch Used in Distribution System)

  • 유행수;한규환;권영일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.536-540
    • /
    • 2002
  • In this paper, accelerated life test (ALT) models and procedures for Magnetic Switch (MS) are developed and applied to assure specified reliability of the products at development phase and guarantee the life of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, ALT models for MS are developed using the relationship between stresses and life characteristics of products. Using the ALT models, we performed life tests and analyzed the tests results. The proposed ALT models and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in world markets.

  • PDF

부하테스트를 이용한 금융 시스템의 성능개선 사례 (A Case Study for Improving Performance of A Banking System Using Load Test)

  • 김태석;이종윤;김종수
    • 한국멀티미디어학회논문지
    • /
    • 제18권12호
    • /
    • pp.1501-1508
    • /
    • 2015
  • In this paper, we describe a case study to improve performance through the load testing of multi-tired system for financial accounts before the system opening. The load test was conducted after the data collection tools(Performance Monitor, DB PSSDiag) were installed. By analyzing the collected log, we were able to identify the main sector requiring performance improvements among the presentation tier, web tier, business logic tier and data tier. The ASP.NET server-down on the web tier could be improved by modifying the parameter values in the configuration file. Some server downs occurred on the business logic tier when a large number of users access at the same time, were more difficult to be solved. By analyzing the hang-dump at the server-down time, we were able to find a process that caused the problem. and we had to modify the relevant codes. For major performance improvements of the data-tier, indices of some queries was optimized by using the built-in DBMS query analyzer, after analyzing the log of long-response-time queries. The problems and solutions considered in this case study will be a reference for the performance improvement of a multi-layer system with the similar structure.

미터링 오리피스를 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구 (A Study on the Phase Bandwidth Frequency of a Directional Control Valve based on the Metering Orifice)

  • 김성동;전세형;윤주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.1-9
    • /
    • 2018
  • The spool displacement of directional control valve can be considered as the standard signal to measure the bandwidth frequency of a directional control valve. When the spool displacement is not available, the metering-orifice system is implemented in this research as an alternative way of measuring the 90 degrees phase bandwidth frequency of the hydraulic directional control valve. The inertia effect on the transmission line oil induces the phase lead of the valve load pressure when compared with the phase of spool displacement. The capacitance effect of the oil induces the phase lag of the valve load pressure. The phase of the load pressure can be adjusted to be the same as that of the spool displacement by controlling the opening area of the metering orifice. A series of experiments were conducted to verify the effectiveness of the metering orifice. The 90 degrees phase bandwidth frequency measured from the valve load pressure was significantly deviated in some cases from the frequency of the spool displacement. The metering orifice was hard to be applied to measure the -90 degrees phase bandwidth frequency of the high precision.

소형 연근해 어선의 조업 시스템 개선에 관한 연구-I -자동 권양 윈치 시스템의 설계- (Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels-I -Design of a Automatic Winch System-)

  • 이대재
    • 수산해양기술연구
    • /
    • 제36권1호
    • /
    • pp.12-24
    • /
    • 2000
  • The electro-hydraulic servo winch system built in a automatic tension control equipment was designed with a latent need for an advanced system in fishing operations of the inshore and coastal fishing vessels. In order to keep the constant tension condition of warp under loading, a tension control circuit was added to the servo winch system.The dynamic performance in the open loop behaviour of the designed winch system was investigated and its applicability was tested for various possibilities of load using a load generator especially developed in order to this study.The mechanical characteristics of this system is different from that of a conventional type, that is, the tension, length, line speed and drum revolution can be automatically controlled by the information from various sensors, such as torque, rpm and pressure transducers. from the experiment results, it was verified that the servo winch system has very good output and tracking behaviour for the control input signals in different operating conditions though overshoot of out 8% in the transient characteristics of torque under the load though a overshoot of about 8% in the transient characteristics of torque under the load condition can be observed when the opening of servo valve, adjustable by the input voltage between - 10 V up to 10 V, changed suddenly.Consequently, the improved fishing winch system can be effectively used as the automatic shooting and hauling equipment of low cost for small inshore and coastal fishing vessels which engage in net fishing.

  • PDF

풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교 (Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test)

  • 천동진;김용철;윤성원
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.

병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석 (Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators)

  • 국정현;이흥호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

시설하우스 중하중용 동력개폐장치 개발 (Development of the thermal curtain opening and closing device under heavy load)

  • 김승희;이공인;김진영;최덕규
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2003년도 하계 학술대회 논문집
    • /
    • pp.372-377
    • /
    • 2003
  • '92년부터 추진한 농업구조개선으로 시설원예 농업은 현대화 대형화되어 환기를 위한 천측창 개폐장치와 보온을 위한 커튼개폐장치의 자동화로 시설원예농업의 편의성을 증대시켰다. 천측창 동력개폐장치에 있어서는 설치개소가 많고 빈번한 작동으로 일찍이 동력개폐기 문제점이 지적되었고, 그에 따른 많은 개선이 이루어졌다 초기의 동력개폐기는 2단 웜기어 감속방식을 사용하여 동력전달효율이 낮아지고 웜기어의 마모로 고장이 잦고 수명이 짧아지는 문제가 있어 감속방식을 유성기어로 전환하여 실용화되면서 많은 발전을 이루어 왔다. (중략)

  • PDF

개구부 경사보강철근이 철근콘크리트 연속 깊은 보의 역학적 거동에 미치는 영향 (Influence of the Diagonal Reinforcement around opening on the Structural Behavior of Reinforced Concrete Continuous Deep Beams)

  • 양근혁;심재일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.382-385
    • /
    • 2006
  • Objective of this study is to understand the diagonal reinforcement around openings on the control of diagonal crack, load distribution, and ultimate strength of reinforced concrete two-span continuous deep beams. Test results of four specimens showed that the strength lost by openings might be completed when diagonal reinforcement ratio was above 0.0014.

  • PDF