• 제목/요약/키워드: Open-Cell Foam

검색결과 38건 처리시간 0.023초

선수 규칙파 중 KCS의 부가저항 및 운동성능 수치해석 (Numerical Simulations of Added Resistance and Motions of KCS in Regular Head Waves)

  • 서성욱;박선호
    • 대한조선학회논문집
    • /
    • 제54권2호
    • /
    • pp.132-142
    • /
    • 2017
  • As the International Maritime Organization (IMO) recently introduced the Energy Efficiency Design Index (EEDI) for new ships building and the Energy Efficiency Operational Indicator (EEOI) for ship operation, thus an accurate estimation of added resistance of ships advancing in waves has become necessary. In the present study, OpenFOAM, computational fluid dynamics libraries of which source codes are opened to the public, was used to calculate the added resistance and motions of the KCS. Unstructured grid using a hanging-node and cut-cell method was used to generate dense grid around a wave and KCS. A dynamic deformation mesh method was used to consider the motions of the KCS. Five wavelengths from a short wavelength (${\lambda}/LPP=0.65$) to a long wavelength (${\lambda}/LPP=1.95$) were considered. The added resistance and the heave & pitch motions calculated for various waves were compared with the results of model experiments.

반경질 폴리우레탄 발포체의 물성에 대한 사슬 연장제와 무기 충전제의 영향 (Effects of Chain Extender and Inorganic Filler on the Properties of Semi-Rigid Polyurethane Foams)

  • 차국찬;송점식;이석민;문무성
    • 폴리머
    • /
    • 제34권1호
    • /
    • pp.8-13
    • /
    • 2010
  • 발포체의 물성은 발포체의 밀도, 사용된 폴리머의 기계적 물성과 열린 셀의 함량, 셀 크기, 셀 크기 분포, 셀 형태, 스킨층의 두께 등을 포함하는 셀 구조에 의존하며, 이러한 발포체의 밀도는 사용된 폴리머의 종류와 가교제의 농도 그리고 가공 기술 및 가공 조건과 같은 다양한 원료 물질과 가교 조건에 영향을 받는다. 본 연구에서는 폴리에스터 폴리올, MDI, 아민계 촉매, 틴계 촉매, 실리콘 유화제, 물을 기본 폴리우레탄 발포체의 조성으로 설정하였으며, 발포체에 있어서 stiff-chain 요소인 사슬 연장제의 첨가에 의하여 가교 밀도를 증가시켰다. 또한, 폴리우레탄 발포체의 기계적 물성을 높이기 위해 무기 충전제로 입자 크기와 $SiO_2$ 함량이 다른 실리카와 탈크 각각 2종류를 사용하였다. 발포체의 제조시 사슬 연장제와 무기 충전제의 종류와 함량비를 달리하면서 모듈러스, 인장 강도, 압축 강도, 경도의 물성 변화를 알아보았고, 전자현미경을 통해 셀의 크기 변화와 무기 충전제의 분포도를 관찰하였다.

행동기관으로서 발의 보온 및 항균방취에 대한 연구 (Research on warmth-keeping, anti-bacteria and deodorant treatment for feet, the active organ of human body)

  • 한상덕;이상도;정중희
    • 대한인간공학회지
    • /
    • 제6권1호
    • /
    • pp.41-44
    • /
    • 1987
  • Researches were made on foot-warming, anti-bacteria and deodorant treatment. Feet, the very important organ to human body, perspire much and their temperature is lower than those of other parts. Hence, keeping feet warm, sanitary and deodorant is the area of this study. Latex sponge of activated carbon, impregnated open cell foam, treated with Vikol DZ-anti-bacteria finishing agent, was developed and tested for warmth-keeping by KSK 0560 test method and for sanitization by AATCC 90 HALO test method and for deodorization by wearing tests. The results show that the new developed latex spongee has warmth-keeping ratio of 2.5 times higher than that of the conventional spong and it has an excellent anti-bacteria effect. Actual wearing function tests also show that it improves significantly the performance of deodorization, sanitization, warmth-keeping and bulkiness.

  • PDF

난류 경계층에서 컴플라이언트 코팅과 점탄성 벽면의 방사 소음에 관한 실험적 연구 (Radiated Sound from Compliant and Viscoelastic Plates in a Turbulent Boundary Layer)

  • 이승배;이창준;권오섭;전우평
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.779-782
    • /
    • 2002
  • We examine the problem in which porous/viscoelastic compliant thin plates are subject to pressure fluctuations under transitional or turbulent boundary layer. Measurements are presented of the frequency spectra of the near-field pressure and radiated sound by compliant surface. A porous plate consisting of 5mm thick, open-cell foam with fabric covering and a viscoelastic painted plate of 1mm thick over an acoustic board of 4m thick were placed over a rigid surface in an anechoic wind tunnel. Streamwise velocity and wall pressure measurements were shown to highly attenuate the convective wall pressure energy when the convective wavenumber ($k_{ch}$) was 3.0 or more. The sound source localization on the compliant walls is applied to the measurement of radiated sound by using an acoustic mirror system.

  • PDF

난류 경계층에서 컴플라이언트 코팅된 벽면과 점탄성 벽면의 방사 소음에 관한 실험적 연구 (Radiated Sound from Compliant and Viscoelastic Plates in a Turbulent Boundary Layer)

  • 이창준;이승배;권오섭;전우평
    • 대한기계학회논문집B
    • /
    • 제27권3호
    • /
    • pp.294-301
    • /
    • 2003
  • We examine a problem in which porous/viscoelastic compliant thin plates are subject to pressure fluctuations under transitional or turbulent boundary layer. Measurements are presented of the frequency spectra of the near-field pressure and radiated sound by compliant surface. A porous plate consisting of 5mm thick. open-cell foam with fabric covering and a viscoelastic-painted plate of 1mm thick over an acoustic board of 4mm thick were placed over a rigid surface in an anechoic wind tunnel. Streamwise velocity and wall pressure measurements were shown to highly attenuate the convective wall pressure energy when the convective wavenumber (k$_{c}$h) was 3.0 or more. The sound source localization on the compliant walls is applied to the measurement of radiated sound by using an acoustic mirror system.

Characteristics and osteogenic effect of zirconia porous scaffold coated with ${\beta}$-TCP/HA

  • Song, Young-Gyun;Cho, In-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.285-294
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate the properties of a porous zirconia scaffold coated with bioactive materials and compare the in vitro cellular behavior of MC3T3-E1 preosteoblastic cells to titanium and zirconia disks and porous zirconia scaffolds. MATERIALS AND METHODS. Titanium and zirconia disks were prepared. A porous zirconia scaffold was fabricated with an open cell polyurethane disk foam template. The porous zirconia scaffolds were coated with ${\beta}$-TCP, HA and a compound of ${\beta}$-TCP and HA (BCP). The characteristics of the specimens were evaluated using scanning electron microscopy (SEM), energy dispersive x-ray spectrometer (EDX), and x-ray diffractometry (XRD). The dissolution tests were analyzed by an inductively coupled plasma spectrometer (ICP). The osteogenic effect of MC3T3-E1 cells was assessed via cell counting and reverse transcriptase-polymerase chain reaction (RT-PCR). RESULTS. The EDX profiles showed the substrate of zirconia, which was surrounded by the Ca-P layer. In the dissolution test, dissolved $Ca^{2+}$ ions were observed in the following decreasing order; ${\beta}$-TCP > BCP > HA (P<.05). In the cellular experiments, the cell proliferation on titanium disks appeared significantly lower in comparison to the other groups after 5 days (P<.05). The zirconia scaffolds had greater values than the zirconia disks (P<.05). The mRNA level of osteocalcin was highest on the non-coated zirconia scaffolds after 7 days. CONCLUSION. Zirconia had greater osteoblast cell activity than titanium. The interconnecting pores of the zirconia scaffolds showed enhanced proliferation and cell differentiation. The activity of osteoblast was more affected by microstructure than by coating materials.

Multi-Termination Technique for the Measurement of Characteristic Impedance and Propagation Constant of Sound Absorbing Materials Using an Impedance Tube

  • Lee, Jong-Hwa;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권2E호
    • /
    • pp.79-84
    • /
    • 2006
  • Acoustic characteristics of a sound absorbing material can be identified, if the characteristic impedance and propagation constants are known, which have generally been determined experimentally. One easy method determining these two essential parameters is to measure the one dimensional wave characteristics in the impedance tube. In th udy, the effects of backing conditions on the impedance tube measurement have been examined using several pairs of generally used end conditions. The results showed that the measured values are similar for most pairs of end conditions: however, it was observed that the measured characteristic impedance for different thickness did not agree well for some pairs. In this work, the multi termination method, using three or more known backing con ns, was suggested to reduce such random errors, which are mostly caused by the test procedure. Employing three terminations as a set, comprised of a rigid end, an end with porous material, and an end with a backing cavity, it was demonstrated that improved measured results could be obtained for an open cell PU foam varying widely with three different thicknesses.

침투성 코팅 처리된 벽면 주위의 벽 압력 특성 (Characteristics of Wall Pressure over Wall with Permeable Coating)

  • 송우석;신승열;이승배
    • 대한기계학회논문집B
    • /
    • 제36권11호
    • /
    • pp.1055-1063
    • /
    • 2012
  • 16채널 어레이 마이크로폰을 이용하여 난류 유동장 내 벽면 압력섭동에 대한 측정을 수행하였다. 본 실험에 사용된 코팅재질은 약 50 ppi (pores per inch)의 다공성 구조로 이루어진 우레탄 물질로 이루어져 있다. 코팅의 주된 목적은 난류 유동장 내 최소한의 공간을 유지하면서 대류속도로 진행하는 난류 와들을 필터링하는 역할을 하는 것이다. 평판 위 경계층의 측정은 열선 유속계를 이용하였으며 표면 마찰계수 값을 얻기위해 CPM법을 사용하였다. 벽압력 스펙트럼과 파수-주파수 스펙트럼 측정은 코팅에 의해 얼마나 에너지가 저감되는 지를 비교하기 위해 사용되었다. 벽면 코팅은 대류하는 무차원 벽면섭동압력에너지를 저감시켰지만, 컴플라이언트 코팅된 벽면 거칠기로 인해 일반 강체 평판에 비해 상대적으로 발달된 경계층을 형성하였으며 벽면 평균전단응력과 저주파수 압력스펙트럼 레벨도 함께 증가하였다.