• Title/Summary/Keyword: Open water efficiency

Search Result 184, Processing Time 0.027 seconds

A Numerical and Experimental Procedure for the Open Water Characteristics of Contra-Rotating Propellers for EEDI Improvement (EEDI 개선을 위한 상반 회전 프로펠러 단독성능 분석용 수치해석과 모형시험에 대한 연구)

  • Kim, Moon Chan;Song, Mu Seok;Kang, Hyeon Ji;Kim, Dong Eon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.4
    • /
    • pp.248-254
    • /
    • 2013
  • Recently, contra-rotating propellers (CRP) having higher efficiency draw much attention since the EEDI regulation of IMO has been enforced. In this paper a numerical method based on the vortex lattice potential theory with a wake model and an experimental procedure with a newly built measuring device, specifically focusing on CRPs, are introduced. And they are applied to a series of CRP known to be designed for the purpose of improving EEDI. The numerical and experimental results showed good agreement explaining the characteristics of the CRP properly. The proposed method is believed to be effectively used for various CRP related studies.

Transformation Characteristics of Chlorinated Aliphatic Hydrocarbon (CAH) Mixtures in a Two-Stage Column: 1st Chemical Column Packed with Zinc Natural Ore and 2nd Biological Column Stimulated with Propane-Oxidizing Microorganisms (아연 광석과 프로판산화 미생물을 이용한 이단 고정상 반응기에서의 염소계 지방족 탄화수소 혼합물 분해 특성)

  • Son, Bong-han;Kim, Nam-hee;Hong, Kwang-pyo;Yun, Jun-ki;Lee, Chae-young;Kwon, Soo-youl;Kim, Young
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.723-730
    • /
    • 2007
  • This study was conducted to develop a combined method for remediating a Chlorinated Aliphatic Hydrocarbons (CAHs) mixtures-contaminated aquifer. The process is consist of two processes. A chemical process (1st) using natural zinc ores for reducing higher concentrations of CAH mixtures to the level at which biological process is feasible; and A biological process (2nd) using aerobic cometabolism for treating lower concentration of CAH mixtures (less than 1 mg/L). Natural zinc ore showed relatively high transformation capacity, average dehalogenation percentage, and the best economic efficiency in previously our study. To evaluate the feasibility of the process, we operated two columns in series (that is, chemical and biological columns). In the first column filled with natural zinc ore and sand, CAH mixtures were effectively transformed with more than 95% efficiency, the efficiency depends on the Empty Bed Contact Time (EBCT) and the mass of zinc ore packed. Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD) analysis were performed to make sure whether natural zinc ore played an key role in the dechlorination of the CAH mixtures. The characteristics of zinc metal surface changed after exposure to CAHs due to oxidation of $Zn^0$ to $Zn^{2+}$. In the biological column injecting propane, DO and effluent of the chemical column, only 1,1,1-TCA was cometabolically transformed. Consequently, the combined process would be effective to remediate an aquifer contaminated with high concentrations of CAH mixtures.

Performance Analysis of Ground Heat Exchanger in Combined Well and Open-Closed Loops Geothermal (CWG) System (밀폐형과 개방형이 결합된 복합지열시스템의 지중열교환기 성능 분석)

  • Park, Youngyun;Song, Jae-Yong;Lee, Geun-Chun;Kim, Ki-Joon;Mok, Jong-Koo;Park, Yu-Chul
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.23-29
    • /
    • 2017
  • This study was conducted to evaluate performance of geothermal heat exchanger (GHE) in the combined well and open-closed loops geothermal (CWG) systems. The CWG systems were designed to combine open loop geothermal heat pumps and closed loop geothermal heat pumps for high energy efficiency. GHE of the CWG systems could be installed at pumping wells for agricultural usage. To get optimal heat exchange capacity of GHE of the CWG systems, 4 GHEs with various materials and apertures were tested at laboratory scale. Polyethylene (PE) and stainless steel (STS) were selected as GHE materials. The maximum heat exchange capacity of GHEs were estimated to be in the range of 33.0~104 kcal/min. The heat exchange capacity of STS GHEs was 2.4~3.2 times higher than that of PE GHE. The optimal cross section area of GHE and flow rate of circulating water of GHE were estimated to be $2,500mm^2$ and 113 L/min, respectively. For more complicated GHE of the CWG systems, it is necessary to evaluate GHEs at various scales.

Development of urban river data management platform(I) (도시하천관리 연계 플랫폼 개발(I))

  • Lee, Sunghack;Shim, Kyucheoul;Koo, Bonhyun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.12
    • /
    • pp.1087-1098
    • /
    • 2019
  • In this study, we developed an integrated urban river data platform that collects, cleans, and provides data for urban river management. The urban river integrated data platform has the function of collecting data provided by various institutions using the Open API service. The collected data is purified through pre-processing and loaded into a database. The collected data can be reviewed and analyzed using a visualization system and provided through the Open API, so that it can be used as individual input data by combining them in the urban river model. In addition, the development system for real-time data was developed to apply real-time data to urban river models. Through this, users will be able to reduce the time and effort required for data collection, pre-processing and input data construction, thereby increasing efficiency and scalability in the development of urban river models and systems.

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

Experimental Analysis on the Performance of a Solar Powered Water Pump (태양열 물펌프의 실험적 성능분석)

  • Kim Y. B.;Son J. G.;Lee S. K.;Kim S. T.;La W. J.;Lee Y. K.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.6 s.107
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.

Parametric study of propeller boss cap fins for container ships

  • Lim, Sang-Seop;Kim, Tae-Won;Lee, Dong-Myung;Kang, Chung-Gil;Kim, Soo-Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.187-205
    • /
    • 2014
  • The global price of oil, which is both finite and limited in quantity, has been rising steadily because of the increasing requirements for energy in both developing and developed countries. Furthermore, regulations have been strengthened across all industries to address global warming. Many studies of hull resistance, propulsion and operation of ships have been performed to reduce fuel consumption and emissions. This study examined the design parameters of the propeller boss cap fin (PBCF) and hub cap for 6,000TEU container ships to improve the propulsion efficiency. The design parameters of PBCF have been selected based on the geometrical shape. Computational fluid dynamics (CFD) analysis with a propeller open water (POW) test was performed to check the validity of CFD analysis. The design of experiment (DOE) case was selected as a full factorial design, and the experiment was analyzed by POW and CFD analysis. Analysis of variance (ANOVA) was performed to determine the correlation among design parameters. Four design alternatives of PBCF were selected from the DOE. The shape of a propeller hub cap was selected as a divergent shape, and the divergent angle was determined by the DOE. Four design alternatives of PBCF were attached to the divergent hub cap, and the POW was estimated by CFD. As a result, the divergent hub cap with PBCF has a negative effect on the POW, which is induced by an increase in torque coefficient. A POW test and cavitation test were performed with a divergent hub cap with PBCF to verify the CFD result. The POW test result showed that the open water efficiency was increased approximately 2% with a divergent hub cap compared to a normal cap. The POW test result was similar to the CFD result, and the divergent hub cap with the PBCF models showed lower open water efficiency. This was attributed to an increase in the torque coefficient just like the CFD results. A cavitation test was performed using the 2 models selected. The test result showed that the hub vortex is increased downstream of the propeller.

High-resolution Urban Flood Modeling using Cellular Automata-based WCA2D in the Oncheon-cheon Catchment in Busan, South Korea (셀룰러 오토마타 기반 WCA2D 모형을 이용한 부산 온천천 유역 고해상도 도시 침수 해석)

  • Choi, Hyeonjin;Lee, Songhee;Woo, Hyuna;Noh, Seong Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.587-599
    • /
    • 2023
  • As climate change increasesthe frequency and risk of flooding in major cities around theworld, the importance ofsimulation technology that can quickly and accurately analyze high-resolution 2D flooding information in large-scale areasis emerging. The physically-based approaches based on the Shallow Water Equations (SWE) often requires huge computer resources hindering high-resolution flood prediction. This study investigated the theoretical background of Weighted Cellular Automata 2D (WCA2D), which simulates spatio-temporal changes offlooding using transition rules and weight-based system, and assessed feasibility to simulate pluvial flooding in the urbancatchment, theOncheon-cheon catchmentinBusan, SouthKorea.Inaddition,the computation performancewas compared by applying versions using OpenComputing Language (OpenCL) andOpenMulti-Processing (OpenMP) parallel computing techniques. Simulationresultsshowed that the maximuminundation depthmap by theWCA2Dmodel cansimilarly reproduce historical inundation maps. Also, it can precisely simulate spatio-temporal changes of flooding extent in the urban catchment with complex topographic characteristics. For computation efficiency, parallel computing schemes, theOpenCLandOpenMP, improved the computation by about 8~14 and 5~6 folds respectively, compared to the sequential computation.

Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector (복사열 반사판의 설계를 위한 광학적 해석 및 실험기법)

  • Jung, Hae-Yong;Song, Tae-Ho;Yoo, Seung-Yeol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

An Experimental Study on Dredging Efficiency for Cutter Head Type (커터헤드 형태에 따른 준설효율에 관한 실험적 연구)

  • Park, Jae Hyeon;Kim, Young Do;Lee, Man Soo
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • In this study, the hydraulic experiments were conducted for the dredging efficiency of the cutter head type, which includes the open type and the close type cutter head. The dredging experimental instrument was installed in the large water tank which has the dimension of $4.9m(L){\times}2.2m(W){\times}1.5m(H)$. The dredging experiments were performed for the various conditions of dredging depth, rotating speed, and suction speed of the cutter head. As the results, the dredging efficiency of the close-type cutter head is much higher than that of the open-type cutter head. The dredging efficiency of the same cutter head type was mainly influenced by the rotating speed of cutter head. Also the adequate suction speed of the cutter head is needed for more effective dredging.