• Title/Summary/Keyword: Open tubular

Search Result 47, Processing Time 0.024 seconds

A primo vessel-like structure in a dog with inflammatory pseudotumor

  • Cho, Sung-Jin;Hong, Sun-Hwa;Han, Sang-Jun;Kim, Ok-Jin
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.1
    • /
    • pp.77-82
    • /
    • 2012
  • Inflammatory pseudotumor (IPT) is a term defining a mass characterized microscopically by a proliferation of bland mesenchymal spindle cells infiltrated by diffuse mixed inflammatory cells with a predominance of plasma cells and lymphocytes. Here, we show the primo vessel-like structure of the primo-vascular system (PVS) in a dog with IPT. A 6-years old male Mongrel dog was diagnosed with an abnormal mass (diameter 5.5 cm, weight 22 g) near left preputial area. The dog was submitted to the surgical detectomy of the mass. During the surgical operation, we observed primo vessel-like material. After fixations, the masses appeared macroscopically as lipoid-like, firm, white to grey masses, measuring $5{\times}8cm$. Histologically, cellular infiltration into the muscular layers was frequently seen. The mesenchymal proliferation remained the main component of the mass and was composed of myofibroblastic-like spindle cells characterized by globular, irregular nuclei containing open chromatin and a prominent nucleolus. On the basis of the histopathologic lesions, the subcutaneous mass was diagnosed as IPT. Also, we detected a primo vessel-like structures in some areas of the IPT tissues. These were observed as novel thread-like structures and bundle of tubular structures. To our knowledge, this report is the first case of primo vessel-like structure in a dog with IPT.

Electrochemical Properties of Segmented-in-series SOFC Using Ni-Fe/YSZ Core-shell Anode (Ni-Fe/YSZ 코어-쉘 구조 연료극을 사용한 다전지식 고체산화물 연료전지의 전기화학적 특성)

  • An, Yong-Tae;Ji, Mi-Jung;Hwang, Hae-Jin;Lee, Min-Jin;Hong, Sun-Ki;Kang, Young-Jin;Choi, Byung-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.357-361
    • /
    • 2014
  • An Ni-Fe/YSZ core-shell structured anode for uniform microstructure and catalytic activity was synthesized. Flat tubular segmented-in-series solid oxide fuel cell-stacks were prepared by decalcomania method using synthesized anode powder. The Ni-Fe/YSZ core-shell anode exhibited better electrical conductivity than a commercially available Ni-YSZ cermet anode. Also power output increased by 1.3 times with a higher open circuit voltage. These results can be attributed to the uniformly distributed Ni particles in the YSZ framework. The impedance spectra of a Ni-Fe/YSZ core-shell anode showed comparable reduced ohmic resistance similar to those of the commercially available Ni-YSZ cermet anodes.

Priliminary Numerical Simulation of the Torque Motor for a Servo Valve in the Fuel Supply System of APU (보조동력장치 연료 공급용 서보밸브 토크모터의 기초 수치모사 연구)

  • Chang, S.M.;Jeong, H.S.;Jang, G.W.;Yang, I.Y.;Lee, W.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • The APU(Auxiliary Power Unit) needs a set of complex pipeline for the fuel supply system where some of the main valves controlling the flow rate consist of the servo valve worked with a torque motor. The input electric current produces an induced magnetic field almost perpendicular to the background magnetic filed generated by fixed permanent magnets. The induced torque deforms the tubular bushing, and directly rotates an armature, which can open and close the valve. In this study, we start from a basic analytic model using a simple electro-magneto-statics, and expand our model to the three-dimensional one computationally applying a commercial code named COMSOL. The result is compared with each other, and reasonable numerical data are obtained for the dynamic behavior and multi-physics system.

  • PDF

Fine structure of the intercalated disc and cardiac junctions in the black widow spider Latrodectus mactans

  • Yan Sun;Seung-Min Lee;Bon-Jin Ku;Myung-Jin Moon
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.20.1-20.9
    • /
    • 2020
  • Arthropods have an open circulatory system with a simple tubular heart, so it has been estimated that the contractile pumping structure of the cardiac muscle will be less efficient than that of vertebrates. Nevertheless, certain arthropods are known to have far superior properties and characteristics than vertebrates, so we investigated the fine structural features of intercalated discs and cardiac junctions of cardiac muscle cells in the black widow spider Latrodectus mactans. Characteristically, the spider cardiac muscle has typical striated features and represents a functional syncytium that supports multiple connections to adjacent cells by intercalated discs. Histologically, the boundary lamina of each sarcolemma connects to the basement membrane to form an elastic sheath, and the extracellular matrix allows the cells to be anchored to other tissues. Since the intercalated disc is also part of sarcolemma, it contains gap junctions for depolarization and desmosomes that keep the fibers together during cardiac muscle contraction. Furthermore, fascia adherens and macula adherens (desmosomes) were also identified as cell junctions in both sarcolemma and intercalated discs. To enable the coordinated heartbeat of the cardiac muscle, the muscle fibers have neuronal innervations by multiple axons from the motor ganglion.

The Operative Treatment of Scapular Glenoid Fracture (견갑골 관절와 골절의 수술적 치료)

  • Kang, Ho-Jung;Jung, Sung-Hoon;Jung, Min;Hahn, Soo-Bong;Kim, Sung-Jae;Kim, Jong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.212-219
    • /
    • 2007
  • Purpose: To determine the causes of the surgical treatment results in glenoid fracture by a retrospective analysis. Materials and methods: From March 1999 to February 2004, 9 patients who underwent an open reduction due to a glenoid fracture were reviewed. The modified Ideberg classification was used. There were 1, 3, 2, 1 and 2 cases of modified Ideberg type I, II, III, V, and VI, respectively. The internal fixators were a reconstruction plate, a small plate, a one-third tubular plate, a small screw, and a cannulated screw in 6, 1, 3, 3 and 1 case, respectively. The constant score and Adam's functional assessment method were used to evaluate the postoperative shoulder function. Results: The average time for fracture union was 7 weeks. The functional assessment was excellent in 4 cases, good in 3 cases, and fair in 2 cases. There were two complications related to surgery; articular screw encroachment, and inferior glenoid bone resorption without instability. Conclusion: A glenoid fracture with glenohumeral instability or displaced that was treated by open surgery showed good clinical results. Moreover, the more comminuted fracture had a lower functional score.

Biportal Endoscopic Spinal Surgery for Lumbar Intervertebral Disc Herniation (두 개의 입구를 통한 내시경 척추 수술: 요추부 추간판 탈출증에의 적용)

  • Lee, Ho-Jin;Choi, Dae-Jung;Park, Eugene J.
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Herniation of the intervertebral disc is a medical disease manifesting as a bulging out of the nucleus pulposus or annulus fibrosis beyond the normal position. Most lumbar disc herniation cases have a favorable natural course. On the other hand, surgical intervention is reserved for patients with severe neurological symptoms or signs, progressive neurological symptoms, cauda equina syndrome, and those who are non-responsive to conservative treatment. Numerous surgical methods have been introduced, ranging from conventional open, microscope assisted, tubular retractor assisted, and endoscopic surgery. Among them, microscopic discectomy is currently the standard method. Biportal endoscopic spinal surgery (BESS) has several merits over other surgical techniques, including separate and free handling of endoscopy and surgical instruments, wide view of the surgical field with small skin incisions, absence of the procedure of removing fog from the endoscope, and lower infection rate by continuous saline irrigation. In addition, existing arthroscopic instruments for the extremities and conventional spinal instruments can be used for this technique and surgery for recurred disc herniation is applicable because delicate surgical procedures are performed under a brightness of 2,700 to 6,700 lux and a magnification of 28 to 35 times. Therefore, due to such advantages, BESS is a novel technique for the surgical treatment of lumbar disc herniation.

The Evaluation of Donor Site after Transfer of Free Osseous and Osteocutaneous Flap of Fibula (유리 생비골 및 생비골 피부편 이식 후 공여부의 평가)

  • Lee, Kwang-Suk;Han, Seung-Bum;Hwang, In-Churl;Song, Hyung-Suk
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.2
    • /
    • pp.75-80
    • /
    • 2001
  • Purpose : We have evaluated the morbidity of donor site after transfer of free fibular osseous and osteocutaneous flap to defect site of bone and soft tissue due to chronic osteomyelitis of long tubular bone, open fracture with bony defect, bone or soft tissue tumor and congenital anomaly. Materials and methods : The 54 cases of 79 cases to be carried out from May, 1982 to May, 2001 which could be followed up were reviewed. There were forty nine in male and five in female. The mean age was 35(4 to 66)years old and mean follow up period is 21.3 month(12 to 72). We have retrospectively analyzed the various postoperative complications such as compartment syndrome, donor site infection, skin defect, hypesthesia, hammer toes, ankle instability and activity of daily living by help of questionnaire, telephone, physical examination, follow up x-ray study and chart. Results : In the total 54 cases the medication period for pain control after operation were classified into three groups under 2 weeks(49 cases), from 2 weeks to 6 weeks(3 cases) and over 6 weeks(2 cases). The postoperative morbidity were occurred in total 12 cases(compartment syndrome: 0, infection : 2, skin defect: 1, hypesthesia: 5, hammer toe: 2 ankle pain: 2 discomfort in activity of daily living: 0), and also the morbidity rates of donor site were 23.5% in osseous flap and 21.6% in osteocutaneous flap were occurred. There was no statistical significonce in morbidity between osseous and osteocutaneous free fibular flap transfer(P>0.05). Discussion : In general the morbidity of free fibular flap transfer was relatively high but it did not have any effect on daily activity of living. We think that the meticulous operation technique, detailed wound care and early range of motion exercise will reduce the morbidity of donor site of flap.

  • PDF

An Experimental Study on the Prediction of Yield Load Using Ring Analysis Method in Circular Tubular X-Type Cross Sections (링해석법에 의한 X형 강관 격점부의 항복하중 예측에 관한 실험적 연구)

  • Park, Il Min;Na, Seon Hong
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.43-54
    • /
    • 1999
  • The divergence connection between steel circular tubes is widely used in such structures as factory facilities, steel circular hollow section truss, and off-shore tower. Steel circular hollow section (SCHS) have close section, and it makes their per-unit production expense higher than open sectioned products like L-shape, H-shape steels, but the sectional resistance of SCHS against vertical compression and torsion is very high. Despite the structural merits of SCHS, however, many engineers dislike to use them in their design because of uncertainty regarding the stress distribution and deformation behavior at their connections. Therefore, this thesis dealt with X-type connections, the most common forms of connection, and studied their load-deformation relationship. It observed how to show the load-deformation relationship at steel circular tube connections according to the diameter-thickness ratio (D/T) of the chord and diameter of branch-diameter of chord ratio (d/D) and suggested prediction yield load using by ring analysis method.

  • PDF

Study on The System Suitability Test for Alcohols Separation by GCOTC (GCOTC에 의한 알코올류 분리를 위한 시스템 적합성에 관한 연구)

  • Oh, Doe Seok;Kim, Sung Hwa;Lee, Seul;Choi, Jae Gu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2017
  • Objectives: The purpose of this study is to enhance the application of analytical method of polar solvents(alcohols) by GCOTC (gas chromatography open tubular column) through the system suitability test(SST) to estimate the whole chromatographic system performance(integral part). Methods: To perform the SST, carried out repeatability(n=6) as analytical method of polar solvents by GCOTC, got the retention time($t_R$), standard deviation(${\sigma}_{n-1}$) of $t_R$, baseline width($w_b=4{\sigma}_{n-1}$) and calculated dead time($t_m$) by $v_m=d^2{\pi}L(f/4)$ and $v_m=t_m$ x flow rate. Results: In this experiment, obtained the basic data, there were $t_m=2$ min, methanol($t_R=3.569$, ${\sigma}_{n-1}=0.01$, $w_b=0.04$), ethanol ($t_R=3.892$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$), isopropanol($t_R=4.209$, ${\sigma}_{n-1}=0.004$, $w_b=0.016$). By using these data, calculated the corrected retention time($t_R{^{\prime}}$), capacity factor(k), separation factor(${\alpha}$), number of theoretical plate(n) and resolution($R_s$) for SST and got the good results. Conclusions: Through the SST, could reconfirm the whole chromatographic performance system(integral part) for analytical method of polar solvents by GCOTC. Therefore, this analytical method expect to be widely applied at the related areas.

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE ADAPTATION OF ROOT CANAL FILLING MATERIAL TO ROOT CANAL WALL WITH AND WITHOUT SMEAR LAYER (Gutta percha 충전시 도말층 유무에 따른 근관벽과의 접합도에 관한 주사전자현미경적 연구)

  • Moon, Joo-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.365-382
    • /
    • 1992
  • The purpose of this study was to evaluate the adaptation of filling material to the dentinal walls of root canals with and without smear layer. Fifty extracted upper and lower anterior teeth were selected, and the root canals were instrumented with K - files 1mm short of the apical foramen by step - back method. The teeth were randomly divided into two groups of 25 each : in the group I, smear layers were not removed, and in the group II, smear layers were removed by 15% EDTA solution. Again the two groups 25 teeth were randomly divided into unfilled contol group and filling groups(lateral, ultrasonic, ULTRAFIL, McSpadden compaction group). Upon completion of root canal filling, the teeth were grooved on the both the labial and lingual surfaces and then split with mallet and chisel. Each specimens were examined with JSM - 840 Scanning Electron Microscope (JEOL., Japan). The results were as follows : 1. In the contol group, dentinal tubules of group I couldn't be distinguished in the canal wall, but those of group II appeared to be open and patent. 2. In the filling groups of group I, the tubular penetration of the sealer or gutta percha couldn't be seen, but in the filling groups of group II, it could be seen except McSpadden compaction group. 3. In the filling groups, ULTRAFIL group showed the best adaptation of filling material to root canal wall among the group I, and lateral and ultrasonic condensation group showed the best adaptation of filling material among the group II. McSpadden compaction group showed the worst adaptation in group I, II. 4. Generally, the group II showed better adapation of filling material to root canal wall than the group I.

  • PDF