• Title/Summary/Keyword: Open circuit

Search Result 1,163, Processing Time 0.025 seconds

Reduction and Analysis for Cogging Torque of Permanent Magnet Synchronous Generators with Multi-Pole Rotor for Wind Power Application (풍력발전용 영구자석 다극 동기발전기의 코깅토크의 해석 및 저감)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.375-383
    • /
    • 2008
  • This paper deals with reduction and analysis of cogging torque for permanent magnet synchronous generators with multi-pole rotor for wind power applications. Open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions, we also derive open-circuit field solutions considering stator slotting effects. By using open-circuit field solutions considering stator slotting effects and energy variation methods, this paper analytically predicts the cogging torque considering skew effects. All analytical results are shown in good agreement with those obtained from finite element (FE) analyses. In order to reduce the cogging torque, by predicting the variation of the cogging torque according to pole arc/pitch ratio using analytical and FE methods, pole arc/pitch ratio which makes the cogging torque minimum are determined. However, we confirm that measured value for cogging torque of the PMG with determined pole arc/pitch ratio is twice higher than predicted value. Therefore, the reason for an error between measured and predicted cogging torque is discussed in terms of a shape of PMs and is proved experimentally.

Detection and Location of Open Circuit Fault by Space Search (Space Search에 의한 회로의 단선 결함을 발견 및 위치 검색법)

  • Han, Kyong-Ho;Kang, Sang-Won;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.43-49
    • /
    • 1995
  • In this paper a space search technique is used to detect and locate the faults of the circuit interconnections. The circuit interconnections are represented by the tree structure and the tree space is searched to detect and locate the open faults of the circuit interconnections. The breadth search is used to detect the open faults and reduce the space size. The depth search is used to locate the open faults.

  • PDF

Study on the Anode Electrode Reaction in the Metal-Air Cell (금속-공기전지의 Anode전극 반응에 관한 연구)

  • Kim, Yong-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.12
    • /
    • pp.1002-1006
    • /
    • 2010
  • In this study, magnesium (Mg), zinc (Zn) and aluminium (Al) as anode electrode and the solution of NaCl dissolved with 2~20 wt% as electrolytes were used for the metal-air cell. The open circuit voltage, short circuit current and I-V characteristics upon different kinds of anode electrode and electrolyte concentration were investigated. The open circuit voltage, initially about 1.45 V, rises to 1.6 V during the first 10 minutes indicating the necessity of an induction time to activate the catalyst on the air cathode. The short circuit current increases with an increased concentration of NaCl, causes an increase in the conductivity of the electrolyte solution, but the open circuit voltage did not under undergo influence of electrolyte. From NaCl 20 wt% electrolyte, the maximum output power of the magnesium electrode materials was measured with 177mW. It is found that the power characteristics of metal-air cell could be improved by using magnesium electrode materials in the NaCl electrolyte.

Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator (30(kVA) 초전도발전기 제작 및 특성)

  • ;;;;;;;I. Muta;I. Hoshino
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF

Design, Analysis, and Equivalent Circuit Modeling of Dual Band PIFA Using a Stub for Performance Enhancement

  • Yousaf, Jawad;Jung, Hojin;Kim, Kwangho;Nah, Wansoo
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.169-181
    • /
    • 2016
  • This work presents a new method for enhancing the performance of a dual band Planer Inverted-F Antenna (PIFA) and its lumped equivalent circuit formulation. The performance of a PIFA in terms of return loss, bandwidth, gain, and efficiency is improved with the addition of the proposed open stub in the radiating element of the PIFA without disturbing the operating resonance frequencies of the antenna. In specific cases, various simulated and fabricated PIFA models illustrate that the return loss, bandwidth, gain, and efficiency values of antennas with longer optimum open stub lengths can be enhanced up to 4.6 dB, 17%, 1.8 dBi, and 12.4% respectively, when compared with models that do not have open stubs. The proposed open stub is small and does not interfere with the surrounding active modules; therefore, this method is extremely attractive from a practical implementation point of view. The second presented work is a simple procedure for the development of a lumped equivalent circuit model of a dual band PIFA using the rational approximation of its frequency domain response. In this method, the PIFA's measured frequency response is approximated to a rational function using a vector fitting technique and then electrical circuit parameters are extracted from it. The measured results show good agreement with the electrical circuit results. A correlation study between circuit elements and physical open stub lengths in various antenna models is also discussed in detail; this information could be useful for the enhancement of the performance of a PIFA as well as for its systematic design. The computed radiated power obtained using the electrical model is in agreement with the radiated power results obtained through the full wave electromagnetic simulations of the antenna models. The presented approach offers the advantage of saving computation time for full wave EM simulations. In addition, the electrical circuit depicting almost perfect characteristics for return loss and radiated power can be shared with antenna users without sharing the actual antenna structure in cases involving confidentiality limitations.

Short-Circuit Current of Polymeric Materials with M1-P-M2 structure in High Temperature Region (고정영역에서 M1-P-M2형 고분자재료의 단락전류)

  • 이덕출;이능헌;임헌찬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.339-345
    • /
    • 1987
  • In the region of high temperature, a very appreciable short-circuit current Is was observed from M1(A1)-P(PET)-M2(Cu) system sandwitched with hetero metals without applying external field. The short-circuit current Is is greatly dependent on electrode material and it has been certified by measuring open-circuit voltage. From these experimental results, we can see that Is is due to electro-chemical action in M-P interface. In this electro-chemical reaction,the generation reaction and the solution reacftion of the oxidies from electrode are probably co-exist and the measured values of the open-circuit voltage was almost correspond to those calculated from Nernst equation.

  • PDF

Stretchable Characteristics and Power Generation Properties of a Stretchable Thermoelectric Module Filled with PDMS (PDMS로 충진된 신축열전모듈의 신축특성과 발전특성)

  • Han, Kee Sun;Oh, Tae Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.149-156
    • /
    • 2019
  • A stretchable thermoelectric module consisting of 5 pairs of Bi2Te3-based hot-pressed p-n thermoelectric legs was processed by filling the module inside with polydimethylsiloxane (PDMS) and removing the top and bottom substrates. Its stretchable characteristics and power generation properties were measured. The integrity of the module was kept well even after 10 strain cycles ranging from 0 to 0.1. With increasing the tensile strain to 0.2, the module circuitry became open because of joint failure between Cu electrodes and thermoelectric legs. The stretchable thermoelectric module exhibited an open circuit voltage of 4.6 mV with a temperature difference of 2.2K across both ends of thermoelectric legs, and changes in its open circuit voltage were below 5% for tensile strains of 0~0.1. Being elongated for a strain of 0.1, it exhibited the maximum output power of 18.5 ㎼ with the temperature difference of 2.2K across its both ends.

Performance Characteristics of Thermoelectric Generator Modules For Parallel and Serial Electrical Circuits (전기회로 구성 방법에 따른 열전발전 모듈 성능 특성)

  • Kim, Yun-Ho;Kim, Myung-Kee;Kim, Seo-Young;Rhee, Gwang-Hoon;Um, Suk-Kee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.5
    • /
    • pp.259-267
    • /
    • 2010
  • An experiment has been performed in order to investigate the characteristics of multiple thermoelectric modules (TEMs) with electrical circuits. The open circuit voltage of TEM connected parallel circuit is equal to the sum of individual TEMs. In contrast, the open circuit voltage is equal to the average of that individual TEM for a series circuit. The power output and conversion efficiency of TEM for both parallel and series circuits increase as the operating temperature conditions for individual TEMs becomes identical. Comparing parallel with series circuits, the power generation performance is more excellent for series circuit than parallel circuit. This result is attributed to the power loss from the TEM with better power generation performance.

A Simple Open-Circuit Fault Detection Method for a Sparse Matrix Converter (스파스 매트릭스 컨버터의 간단한 개방 사고 검출 기법)

  • Lee, Eunsil;Lee, Kyo-Beum;Joung, Gyu-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.217-224
    • /
    • 2013
  • This paper presents a diagnostic method for a sparse matrix converter that detects faults in any single switch or a pair of switches. The sparse matrix converter is functionally equivalent to the standard matrix converter but has a reduced number of switches. The proposed diagnostic method is based in the measurement of input and output currents. The currents have respective characteristic according to the location of faulty switches. This method not only detects the switches of open-circuit fault but identifies the location of the faulty switching devices without complicated calculations. The simulation and experimental results verify that, based on the proposed method, the fault of sparse matrix converter can be easily and fast detected.