• Title/Summary/Keyword: Open Door

Search Result 261, Processing Time 0.026 seconds

Effect of living room air purifier on reducing PM2.5 in living room and bedroom (거실의 공기청정기가 거실과 침실의 초미세먼지 농도 저감에 미치는 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.17 no.4
    • /
    • pp.107-114
    • /
    • 2021
  • In this study, the effect of the air purifier located in the living room on the reduction of PM2.5 concentration in the living room and bedroom was investigated. Measurements were carried out in real-life for about 2 weeks in a Korean apartment building where a 3-person household had lived and the exclusive private area was 84.9 m2. When the air purifier in the living room was operating, the change in PM2.5 concentration was measured when the door to the bedroom connected to the living room was opened and closed. In the case of living with the bedroom door open, the average PM2.5 concentrations in the living room and bedroom were almost the same. When living with the bedroom door closed, the average PM2.5 in the living room was higher than in the bedroom. The ventilation and cooking effects in the living room mainly affected the PM2.5 concentration in the living room. Only one air purifier in the living room was able to keep the PM2.5 concentration in the living room and bedroom low.

A Prediction of the Indoor Air Movement and Contaminant Concentration in a Multi-Room Condition

  • Song, Doo-Sam;Kang, Ki-Nam;Park, Dong-Ryul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.137-146
    • /
    • 2007
  • CFD simulation is a very useful tool to predict the concentration of contaminant generated from the building materials in a single room. However, there is a limitation on analyzing air movement and contaminant concentration in a multi-room when the door of each room is closed. In this study, network based simulation was coupled with contaminant simulation for the multi-room condition, using an network simulation tool 'ESP-r'. The coupled simulation was first validated with experimental measurements which performed to define the characteristics of the analyzed space prior to the simulation, and indoor air flow and contaminant concentration between rooms were then analyzed when the door of each room was open and closed in the case of natural and forced ventilation.

KEY TECHNIQUES IN DEVELOPMENT OF VEHICLE GLASS DROP DESIGN SYSTEM

  • Liu, B.;Jin, C.N;Hu, P.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.327-335
    • /
    • 2007
  • A new optimization scheme and some key techniques are proposed in the development of a vehicle glass drop design software system. The key issues of the design system are how to regenerate the glass surface and make the vehicle glass drop down along the glass channels. To resolve these issues, a parameterized model was created at first, in which the optimizing method and Knowledge Fusion techniques were adopted the optimized process was then written into the glass drop design system by coding with C language and UGS/Open Application Programme Interface functions etc. Therefore, the designer or engineer can simulate the process of glass dropping along the channels to assess the potential interference between glass and door accessory by using this software system. All of the testing results demonstrate the validity of the optimizing scheme, and the parametric design software effectively solves the key issues on development of the door accessory package.

Field Experiments on Stack Effect in Stairwells of High-Rise Building (고층건물 피난계단에서의 연돌효과에 대한 현장실험)

  • Kim, Jung-Yup
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.459-462
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The architectural factors affecting the pressure field of building should be examined for the successful design and operation of smoke management system and the stack effect is one of the important factors. The field experiments on stack effect in stairwells of high-rise building with regard to open/close condition of door are carried out to evaluate the features of pressure applied to door between each compartments, i.e, stair, lobby and accommodation. The procedures and results of experiments are presented.

  • PDF

Implementation of an Open Artificial Intelligence Platform Based on Web and Tensorflow

  • Park, Hyun-Jun;Lee, Kyounghee
    • Journal of information and communication convergence engineering
    • /
    • v.18 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • In this paper, we propose a web-based open artificial intelligence (AI) platform which provides high convenience in input data pre-processing, artificial neural network training, and the configuration of subsequent operations according to inference results. The proposed platform has the advantages of the GUI-based environment which can be easily utilized by a user without complex installation. It consists of a web server implemented with the JavaScript Node.js library and a client running the tensorflow.js library. Using the platform, many users can simultaneously create, modify and run their projects to apply AI functionality into various smart services through an open web interface. With our implementation, we show the operability of the proposed platform. By loading a web page from the server, the client can perform GUI-based operations and display the results performed by three modules: the Input Module, the Learning Module and the Output Module. We also implement two application systems using our platform, called smart cashier and smart door, which demonstrate the platform's practicality.

Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System (특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구)

  • Lee, Su-Kyung;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.85-90
    • /
    • 2011
  • This study of the vestibule of pressurizing smoke control system installed in domestic high-rise buildings for evacuation in case of fire, when the door is open to forming characteristics of the air flow was analyzed using fire dynamics simulator and analyzed of variance. Vestibule which is compartment of the design condition, air flow in the exhaust damper was formed severe turbulence confirming preceding research. The door position is in the range of formed vortex, unsteady flow of air occurs at the point that the door could be confirmed. According to the NFSC 501A, door to symmetrically separate the average of 10 points or more as measured from the average of wind speed to do is based. Under these conditions, it is difficult to measure the characteristics of the upper air flow of upper points. so measuring points are subdivided by more than 64 points method presented in TAB because severe deviation of wind speed.

A Study on the improvement the efficiency of the evacuation of the ship's crews (선박 승무원의 피난 효율 향상에 관한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.153-154
    • /
    • 2013
  • In this study, we used the program of three-dimensional analysis of fire for analyzing visibility of smoke flow and temperature of the accommodation area what is required for the analysis of survival of the crew. In particular, I would like to propose a method for reducing the flow rate performance in order to reduce the suffocation from the smoke of the majority of personal injury. Existing vessels are designed to close the fire door automatically when the fire alarm issued. When there is no crew that dared to escape, it can delay the spread of fire and smoke flow which is determined to be very useful to improve the survival rate of the crew. However, it can be fatal to the crew whose rooms are located on the inside of the fire door that has not completed the evacuation. In this study, we check the smoke flow rate and rate of temperature rise when crew open the fire door what is closed due to fire and compare to the structure of the blocking layer.

  • PDF

An Experimental Study on the Mechanical Mounting between GFRP Door Impact Beam and Steel Brackets (GFRP 도어 임팩트 빔과 Steel 브래킷의 기계적 결합에 관한 실험적 연구)

  • Ha, Jung-Chan;Shin, Young-cheol;Baek, In-Seok;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.5
    • /
    • pp.103-110
    • /
    • 2021
  • The mounting performance of the GFRP(Glass fiber Reinforced Plastic) beam and the mechanical mounting of the steel bracket was studied to be mounted as a GFRP impact beam on the side door of the passenger car. Moreover, an open-hole tensile test was performed to evaluate breakage tendency based on GFRP stacking conditions. Furthermore, the tightening strength of rivets and bolts was compared using the single lap-shear tension test for the GFRP stacking pattern. Additionally, the GFRP beam and bracket mounting features were designed; moreover, the prototype and bracket were assembled. Additionally, the bracket mounting bending test and the door assembly static bending test were performed to verify the stability of the bracket mounting. In the bracket fastening bending test, no breakage occurred in the connection part between the GFRP beam and the bracket, and it showed 67% (24.4 kN) improved performance compared to steel. In the static bending test of the door assembly, the initial average reaction force increased by 25% compared to the steel, and the performance of all FMVSS-214 regulations was satisfied. The replacement of GFRP impact beams resulted in a 30% weight reduction

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

Predicting Influence of Changes in Indoor Air Temperature and Humidity of Wooden Cultural Heritages by Door Opening on Their Conservation Environment (개방에 따른 실내 온습도 변화가 목조문화재 보존환경에 미치는 영향 예측)

  • Kim, Min-Ji;Shin, Hyun-Kyeong;Choi, Yong-Seok;Kim, Gwang-Chul;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.798-803
    • /
    • 2015
  • This study was conducted to predict the effect of door opening in wooden cultural heritages (WCHs) on their conservation environment. For this prediction, measured relative humidity (RH) and surface wood moisture content (MC) of inner part of wood columns in open wooden building and neighboring closed wooden building were compared with minimum RH, including the duration of minimum RH, and MC required for spore germination and resultant growth of wood-degrading fungi reported in some literatures. Moisture conditions, namely RH of inside wooden building and MC of wood was unsuitable for decay and sap-stain fungi all the year round; however, moisture conditions during summer season was suitable for spore germination and resultant growth of surface mold fungi, regardless of door opening. When compared, the duration of minimum (75%) or higher RH and the number of wood columns with MC level greater than the minimum MC (15%) during summer season, the surface mold related to the conservation environment of inside wooden building was somewhat better in open building than in closed building. Rather, doors should be opened in closed building for reducing indoor RH as a necessary measure during summer season when outdoor RH is high.