• Title/Summary/Keyword: Open Door

Search Result 261, Processing Time 0.026 seconds

Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate (스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구)

  • Kim, Min-Jae;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.59-64
    • /
    • 2016
  • The PSD (Platform Screen Door System) has been installed to enhance the passengers' safety. A total of 592 stations operate the PSD system, which is almost 71.8% of all stations in South Korea. This study compared the opening rate between the PSD and train door, and calculated the exact amount of passengers at peak time. In addition, the evacuation time was simulated by Pathfinder 2015 with the exact input data. Some of the high density stations have extremely high dangerous points about the passengers' evacuation at some situations by the PSD door opening rate. In particular, due to the interference of a fixed door, when it stops at 7 m less than the regular position, its opening rate becomes less than half of the normal state. To solve this problem, it should be made possible to open the fixed door by changing it to an emergency door or improving the PSD module system.

Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade (지하상가 출입구 방풍문 설치에 따른 피난안전해석)

  • Choi, Young-Sang;Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • This paper presents a study on the evacuation analysis in underground arcade. In this study, the effect of the exit with a windbreak door has been investigated by using evacuation simulation program (building EXODUS). Also, the simulation has included the impact of smoke, heat and toxic gases by fire simulation program (CFAST). The results were obtained for the conditions of without and with door of the two exit with 1,088 evacuation population. As a results, for non-fire evacuation, there was only a little difference of evacuation time for both conditions. However, for fire emergency evacuation, the evacuation time for the condition with door increased more 110 seconds than for the condition without door. When the auto door not opened, the evacuation time was increased more 670 seconds than for the condition without door. Consequently, in case of fire, the automatic door should be operating by the signal of fire detector and keep open when the fire accidents. To lead the evacuees well to the escape route the luminaries for an emergency exit sign have to be reinforced to the wall and floor around the exit.

Design of Image Processing System Additional into Automatic Access Control Door (안면인식 시스템을 탑재한 출입문 자동제어 시스템 설계)

  • Lee, Jae-ung;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.261-263
    • /
    • 2017
  • Future science fiction science film science fiction film can easily see the appearance of the futuristic inquiry. Even if a person does not open the door by force, the door is opened and closed by the system. Even now, such a door can be found easily. However, in the past, people who have not been able to perceive people have been used only in public places such as department stores and marts, where there are many people who are inundated. However, a lot of researches are being done now, and we are pursuing convenience in everyday life by integrating the image processing technology that has been developed and developed many times, by implementing the automatic door which is not infringed by the personal life and is impossible for anyone to access.

  • PDF

ANALYTIC AND GEOMETRIC PROPERTIES OF OPEN DOOR FUNCTIONS

  • Li, Ming;Sugawa, Toshiyuki
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.267-280
    • /
    • 2017
  • In this paper, we study analytic and geometric properties of the solution q(z) to the differential equation q(z) + zq'(z)/q(z) = h(z) with the initial condition q(0) = 1 for a given analytic function h(z) on the unit disk |z| < 1 in the complex plane with h(0) = 1. In particular, we investigate the possible largest constant c > 0 such that the condition |Im [zf"(z)/f'(z)]| < c on |z| < 1 implies starlikeness of an analytic function f(z) on |z| < 1 with f(0) = f'(0) - 1 = 0.

Field Experiments on Features of Airflow through Open Door in Pressure Differential System (급기가압 제연시스템의 피난문 개방시 방연풍속 형성특성에 대한 현장실험)

  • Kim, Jung-Yup;Rie, Dong-Ho;Kim, Ha-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.463-467
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The field experiments on pressure differential systems for smoke management in two high buildings of 20 stories and 21 stories are carried out to evaluate the features of airflow through open door between accommodation and lobby. The procedures and results of experiments are presented.

  • PDF

Smartphone Color-Code based Gate Security Control

  • Han, Sukyoung;Lee, Minwoo;Mariappan, Vinayagam;Lee, Junghoon;Lee, Seungyoun;Lee, Juyoung;Kim, Jintae;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.5 no.3
    • /
    • pp.66-71
    • /
    • 2016
  • Smart building gate security control system using smartphone integrated with near field communication (NFC) has become part of daily life usage these days. The technology change in replacing RF NFC device using visible light communication technology based approach growing faster in recent days. This paper propose a design and development of gate security control system using color code based user authentication ID generation as part of an intelligent access control system to control automatic door open and close. In this approach gate security access control use the recent visible light communication technology trends to transfer the user specific authentication code to door access control system using color code on smartphone screen. Using a camera in the door access control system (ACS), color codes on smartphone screens are detected and matched to the database of authenticated user to open the door automatically in gate security system. We measure the visual light communication technology efficiency as a part of the research and the experiments have revealed that more than 95% users authenticated correctly at the suggested experiment environment on gate security control system.

Surgical Results of en Bloc Open-door Laminoplasty

  • Kim, Seok-Won;Lee, Seung-Meung;Shin, Ho;Kim, Hyun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.2
    • /
    • pp.102-106
    • /
    • 2005
  • Objective : The purposes of this study are to evaluate the efficacy of en bloc open-door laminoplasty and to investigate the validity of various factors as prognotic indicators in patients with multisegmental spondylotic myelopathy and ossification of posterior longitudinal ligament[OPLL]. Methods : The authors reviewed 43 cases in whom laminoplasty were performed for cervical myelopathy between January 2000 and December 2002. Clinical symptoms and results were evaluated using the Japanese Orthopaedic Association[JOA] scale. The recovery rate was calculated and then assessed for prognostic factors such as preoperative JOA scores, ages, history of previous trauma, duration of symptoms and signal change in cord on T2-weighted magnetic resonance Image. Results : In cervical stenosis, canal widening of antero-posterior diameter and dimension after laminoplasty is 4.16mm, $87.43mm^2$ and in OPLL is 6.20mm, $117.61mm^2$. In all cases there wasn't neurologic deterioration, mild postoperative complications developed in seven cases. Four patient had a limitation of range of neck motion and the other one showed kyphotic change and another two showed C5 radiculopathy. The recovery rate of JOA score in cervical stenosis and OPLL was 62% and 68% respectively. Duration of symptoms, the severity[preoperative JOA score], and signal change in cord on T2-weighted magnetic resonance image had close relationship to the clinical outcomes. Conclusion : Unilateral en bloc laminoplasty is simultaneous expansile and decompressive method. And preoperative JOA score, symptom duration and high signal intensity on T2-weighted magnetic resonance image can be used to predict prognosis.

The Study on the transition of types of Deul-E-Yul-Gae windows and doors in Korean traditional architecture - focused on the wall between Dae Chung and Bang - (傳統建築의 들어열개 窓戶形式 變遷에 관한 硏究 - 廳房間을 중심으로 -)

  • 정명섭
    • Journal of the Korean housing association
    • /
    • v.7 no.2
    • /
    • pp.57-68
    • /
    • 1996
  • The study is to investiagte the transition of types of Deul-E-Yul-Gae(lift up) windows and doors in Korean traditional architecture which was on the wall batween Dar Chung and Bang. As the result of studying and analysizing the transition of those the following conclusion could be obtained. The first type was to attach windows on the middle of Deul-E-Yul-Gas(lift up) doors, the second type remove windows attached on that or be(Maeng-Jang-Jee) dark paper covered door annexed Bool-Bal-Gee, and the third type to be (Myung-Jang-Jee) bright paper covered door of bottom panel slender ribs which was the most openness. Finally, we could understand the transition which would be changed from the type of(Maeng-Jang-Jee) bright paper covered lift up door of bottom panel slender ribs that had a pliable and open mood.

  • PDF

An Study on control of explosion pressure in enclosure (내압 폭발 압력 조정에 관한 연구)

  • Kim, Hong-Sik;Oh, Dae-Hee;Oh, Kyu-Hyung;Choi, Beom-Shik;Lee, Sung-Eun;Moon, Young-Gil
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.189-193
    • /
    • 2008
  • A Control variables of explosion pressure in enclosure are a type of explosive gas, concentration of mixture, open area in enclosure. In this study, be performed to test inner explosion pressure of Blast Proof Door by the control variables of explosion pressure. and this real explosion test of Blast Proof Door have a good point in test of the against pressure method that can be obtained dynamic pressure or not static pressure.

  • PDF