• Title/Summary/Keyword: Opc

Search Result 968, Processing Time 0.035 seconds

A Study on Development of an Integrated HMI System based on Embedded OPC Server (임베디드 OPC 기반의 통합형 HMI 시스템 개발에 관한 연구)

  • Yeo, Hoon-Koo;Rim, Seong-Rak;Han, Kwang-Rok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.5
    • /
    • pp.1-10
    • /
    • 2008
  • In this paper, we discuss the development of an integrated HMI system based on OPC(OLE for Process Control) to control and monitor an automation equipment in the diverse environment. We implement an embedded OPC server according to the OPC standard which is proposed as the communication standard mechanism in the process control field, and design the interface module in which the output data of the OPC server can be connected to various HMI environment such as the local application, intranet client and Web page. This paper will be contributed in the HMI system implementation for the ubiquitous environment because it is possible to make remote control on the network and Web monitoring as well as the connection and data exchange of heterogeneous equipments by applying to various control systems.

  • PDF

Physical Properties of Cement Blended Finex-Slag Powder (파이넥스 슬래그 미분말을 혼합한 시멘트의 물성)

  • Lee, Keun-Jae;Byun, Seung-Ho;Choi, Hyun-Kook;Song, Jong-Taek
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.375-380
    • /
    • 2010
  • In this study, physical properties of cement blended with Finex-slag powder(OPC-FS) were investigated by the measurement of flowability, compressive strength, hydration heat, and $Ca(OH)_2$ content. In addition, those properties of the cement blended with blast furnace slag(OPC-BFS) were also measured for comparison. It was found that OPC-FS and OPC-BFS showed similar trend in the rheological properties. In the blended cement pastes with the $4,000\;cm^2/g$ Blaine value the flowability of OPCFS was better than that of OPC-BFS. The initial 3 day mortar compressive strength and the hydration heat of paste of OPC-FS was a bit higher, compared with OPC-BFS. Accordingly $Ca(OH)_2$ produced in the cement hydration was decreased very rapidly.

Mechanical behaviour of waste powdered tiles and Portland cement treated soft clay

  • Al-Bared, Mohammed A.M.;Harahap, Indra S.H.;Marto, Aminaton;Abad, Seyed Vahid Alavi Nezhad Khalil;Mustaffa, Zahiraniza;Ali, Montasir O.A.
    • Geomechanics and Engineering
    • /
    • v.19 no.1
    • /
    • pp.37-47
    • /
    • 2019
  • The main objective of this study is to evaluate and compare the efficiency of ordinary Portland cement (OPC) in enhancing the unconfined compressive strength of soft soil alone and soft soil mixed with recycled tiles. The recycled tiles have been used to treat soft soil in a previous research by Al-Bared et al. (2019) and the results showed significant improvement, but the improved strength value was for samples treated with low cement content (2%). Hence, OPC is added alone in this research in various proportions and together with the optimum value of recycled tiles in order to investigate the improvement in the strength. The results of the compaction tests of the soft soil treated with recycled tiles and 2, 4, and 6% OPC revealed an increment in the maximum dry density and a decrement in the optimum moisture content. The optimum value of OPC was found to be 6%, at which the strength was the highest for both samples treated with OPC alone and samples treated with OPC and 20% recycled tiles. Under similar curing time, the strength of samples treated with recycled tiles and OPC was higher than the treated soil with the same percentage of OPC alone. The stress-strain curves showed ductile plastic behaviour for the untreated soft clay and brittle behaviour for almost all treated samples with OPC alone and OPC with recycled tiles. The microstructural tests indicated the formation of new cementitious products that were responsible for the improvement of the strength, such as calcium aluminium silicate hydrate. This research promotes recycled tiles as a green stabiliser for soil stabilisation capable of reducing the amount of OPC required for ground improvement. The replacement of OPC with recycled tiles resulted in higher strength compared to the control mix and this achievement may results in reducing both OPC in soil stabilisation and the disposal of recycled tiles into landfills.

Optimal OPC Position and Fiber Dispersion Coefficients depending on WDM Channel Numbers (WDM 채널수에 따른 최적의 OPC 위치 및 광섬유 분산 계수)

  • Lee, Seong-Real;Chung, Jae-Pil
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.2
    • /
    • pp.177-186
    • /
    • 2007
  • In this paper, the optimal position offset of optical phase conjugator (OPC) and the optimal dispersion offsets of fiber sections, which are alternating with the method for the symmetry of optical power and chromatic dispersion with respect to OPC, are numerically investigated as afunction of the WDM channel numbers. The WDM channel numbers are assumed to be 8, 12, 16, 20 and 24. The bit-rate of each channel is assumed to be 40 Gbps for all cases. It is confirmed that the optimal position offset of OPC and optimal dispersion offset of fiber section are gradually increased as the WDM channel numbers are gradually increased. But, the optimal dispersion values of fiber sections per OPC position offset of 1 km are independent on WDM channel numbers, because the optimal position offset of OPC and optimal dispersion offset of fiber section are simultaneously increased as the WDM channel numbers are increased. It is also confirmed that the applying of these optimal parameter values is efficient to WDM system with many channels rather than WDM with small channels.

  • PDF

Compensation for the Distorted WDM Channels through the Dispersion-managed Optical Links with Non-midway Optical Phase Conjugator (Non-midway 광 위상 공액기를 갖는 분산 제어 전송 링크를 통한 WDM 채널의 왜곡 보상)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.595-600
    • /
    • 2015
  • The implementation possibility of the flexible optical network configuration using the non-midway optical phase conjugator (OPC) in the dispersion-managed (DM) optical link for wavelength division multiplexed (WDM) transmission is demonstrated in this paper. It is confirmed that the implementation possibility of flexible link configuration is more increased, as number of fiber spans is more bigger and the residual dispersion per span (RDPS) is more large. It is also confirmed that the non-midway OPC link, in which RDPS of the latter half transmission section (after OPC) is decided by the averaged RDPS of the former half transmission section (before OPC), has more advantage for the flexible network configuration.

New Control System Aspects for Supporting Complex Data and High Performance System

  • Yoo, Dae-Seung;Tan, Vu Van;Yi, Myeong-Jae
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.4
    • /
    • pp.394-411
    • /
    • 2008
  • The data in automation and control systems can be achieved not only from different field devices but also from different OPC (OLE for Process Control) servers. However, current OPC clients can only read and decode the simple data from OPC servers. They will have some problems to acquire structured data and exchange the structured data. In addition to the large network control systems, the OPC clients can read, write, and subscribe to thousands of data points from/to OPC servers. Due to that, the most important factor for building a high performance and scalable industrial control system is the ability to transfer the process data between server and client in the most efficient and fastest way. In order to solve these problems, we propose a means to implement the OPC DA (Data Access) server supporting the OPC complex data, so that the OPC DA clients are able to read and decode any type of data from OPC servers. We also propose a method for caching the process data in large industrial control systems to overcome the limitation of performance of the pure OPC DA system. The performance analysis and discussion indicate that the proposed system has an acceptable performance and is feasible in order for applying to real-time industrial systems today.

Development of an OPC Client-Server Framework for Monitoring and Control Systems

  • Tan, Vu Van;Yi, Myeong-Jae
    • Journal of Information Processing Systems
    • /
    • v.7 no.2
    • /
    • pp.321-340
    • /
    • 2011
  • In this article, the current technological state of OPC (Openness, Productivity, and Collaboration; formerly "OLE for Process Control") standards and the problem statement of these OPC standards are discussed. The development of an OPC clientserver framework for monitoring and control systems is introduced by using the new OPC Unified Architecture (UA) specifications, Service Oriented Architecture (SOA), web services, XML, etc. The developed framework in turn minimizes the efforts of developers in learning new techniques and allows system architects and designers to perform dependency analysis on the development of monitoring and control applications. The potential areas of the proposed framework and the redundancy strategies to increase the efficiency and reliability of the system are also represented according to the initial results from the system that was developed by the Visual Studio 2008 and OPC UA SDK.

Compensation for Distorted Signals by using Optimal Pump Light Power in WDM Systems with Non-midway Optical Phase Conjugator

  • Lee Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7A
    • /
    • pp.542-549
    • /
    • 2005
  • In this paper, the optimal pump light power of optical phase conjugator (OPC) and the compensation characteristics of distorted WDM channel signals are numerically investigated, when the OPC with highly-nonlinear dispersion shifted fiber (HNL-DSF) not be placed at the mid-way of total transmission length. The total dispersion of former half section and latter half section is assumed to be same each other in this approach. It is confirmed that, in WDM transmission systems with OPC deviated from the mid-way, the pump light power for best compensation must be flexible selected depending on the OPC position. This optimal pump light power is gradually increased as the OPC is gradually closer to the receiver. Consequently, it is possible to establish the compensation system independent on the OPC position by setting optimal pump light power connected with the OPC position.

The Development of OPC Server for Communication between Simulation Model and External Application (시뮬레이션 모델과 외부 Client 간의 연동을 위한 OPC Server개발)

  • 박신열;이명수;서인용;홍진혁
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.153-157
    • /
    • 2003
  • 전력연구원에서는 울진 표준형원전의 시뮬레이터를 개발하였으며, 여기에는 가상 주제어실, 발전소 현상 감시, 중대사고 등 많은 클라이언트 프로그램들이 있다. 이러한 프로그램들은 시뮬레이터와 연동되어 필요한 값을 읽고 쓰는 과정이 필요하다. 그러나 현재는 해당 시뮬레이터 환경에서 개발되지 않는 외부의 응용프로그램이 이들 시뮬레이터의 값들을 엑세스하는 방법은 제공하지 않고 있다. 본 보고서에서는 이러한 문제점을 해결하기 위해 외부 프로그램들이 시뮬레이션모델의 각종 변수들을 효과적으로 엑세스하여 값을 Read/write 할 수 있는 OPC (OLE for Process Control) Server를 개발하였다. 본 프로그램은 Rockwell의 OPC Server Toolkit인 RSI OPC/DDE Server Toolkit Library를 이용하여 개발하였으며 시뮬레이터가 실행되고 있는 컴퓨터에서 실행된다. 본 보고서에서는 OPC 일반개념, 개발한 OPC Server의 소개, OPC Server의 적용결과 등을 기술하고자 한다.

  • PDF

Java2OPC Gateway: OPC Access in Various Platform (Java2OPC Gateway: 다양한 플랫폼에서의 OPC 접근)

  • Yoo, Dae-Sung;Sim, Min-Suck;Park, Sung-Ghue;Park, Jae-Hee;Kim, Jong-Hwan;Yi, Myoung-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.1323-1326
    • /
    • 2004
  • 본 연구에서는 OPC(OLE for Process Control)가 마이크로소프트의 COM(Component Object Model)과 DCOM(Distributed COM) 기술을 사용함으로써 윈도우즈 플랫폼에서 클라이언트 어플리케이션이 개발되어 져야 하는 제약을 해결하기 위하여 Java2OPC Gateway를 제안한다. Java2OPC Gateway는 프로세스 컨트롤 장비와 연결된 OPC 서버쪽과 통신하는 클라이언트의 기능과 다양한 플랫폼에서 프로세스 데이터에 접근하기 위한 자바 어플리케이션과 통신하는 서버의 기능을 가진다. 클라이언트 모듈은 C로 작성되고 서버 모듈은 Java로 작성되어 클라이언트 모듈과 서버 모듈은 JNI(Java Native Interface)로 연결 된다.

  • PDF