Journal of the Korea Society of Computer and Information
/
v.13
no.5
/
pp.1-10
/
2008
In this paper, we discuss the development of an integrated HMI system based on OPC(OLE for Process Control) to control and monitor an automation equipment in the diverse environment. We implement an embedded OPC server according to the OPC standard which is proposed as the communication standard mechanism in the process control field, and design the interface module in which the output data of the OPC server can be connected to various HMI environment such as the local application, intranet client and Web page. This paper will be contributed in the HMI system implementation for the ubiquitous environment because it is possible to make remote control on the network and Web monitoring as well as the connection and data exchange of heterogeneous equipments by applying to various control systems.
In this study, physical properties of cement blended with Finex-slag powder(OPC-FS) were investigated by the measurement of flowability, compressive strength, hydration heat, and $Ca(OH)_2$ content. In addition, those properties of the cement blended with blast furnace slag(OPC-BFS) were also measured for comparison. It was found that OPC-FS and OPC-BFS showed similar trend in the rheological properties. In the blended cement pastes with the $4,000\;cm^2/g$ Blaine value the flowability of OPCFS was better than that of OPC-BFS. The initial 3 day mortar compressive strength and the hydration heat of paste of OPC-FS was a bit higher, compared with OPC-BFS. Accordingly $Ca(OH)_2$ produced in the cement hydration was decreased very rapidly.
Al-Bared, Mohammed A.M.;Harahap, Indra S.H.;Marto, Aminaton;Abad, Seyed Vahid Alavi Nezhad Khalil;Mustaffa, Zahiraniza;Ali, Montasir O.A.
Geomechanics and Engineering
/
v.19
no.1
/
pp.37-47
/
2019
The main objective of this study is to evaluate and compare the efficiency of ordinary Portland cement (OPC) in enhancing the unconfined compressive strength of soft soil alone and soft soil mixed with recycled tiles. The recycled tiles have been used to treat soft soil in a previous research by Al-Bared et al. (2019) and the results showed significant improvement, but the improved strength value was for samples treated with low cement content (2%). Hence, OPC is added alone in this research in various proportions and together with the optimum value of recycled tiles in order to investigate the improvement in the strength. The results of the compaction tests of the soft soil treated with recycled tiles and 2, 4, and 6% OPC revealed an increment in the maximum dry density and a decrement in the optimum moisture content. The optimum value of OPC was found to be 6%, at which the strength was the highest for both samples treated with OPC alone and samples treated with OPC and 20% recycled tiles. Under similar curing time, the strength of samples treated with recycled tiles and OPC was higher than the treated soil with the same percentage of OPC alone. The stress-strain curves showed ductile plastic behaviour for the untreated soft clay and brittle behaviour for almost all treated samples with OPC alone and OPC with recycled tiles. The microstructural tests indicated the formation of new cementitious products that were responsible for the improvement of the strength, such as calcium aluminium silicate hydrate. This research promotes recycled tiles as a green stabiliser for soil stabilisation capable of reducing the amount of OPC required for ground improvement. The replacement of OPC with recycled tiles resulted in higher strength compared to the control mix and this achievement may results in reducing both OPC in soil stabilisation and the disposal of recycled tiles into landfills.
In this paper, the optimal position offset of optical phase conjugator (OPC) and the optimal dispersion offsets of fiber sections, which are alternating with the method for the symmetry of optical power and chromatic dispersion with respect to OPC, are numerically investigated as afunction of the WDM channel numbers. The WDM channel numbers are assumed to be 8, 12, 16, 20 and 24. The bit-rate of each channel is assumed to be 40 Gbps for all cases. It is confirmed that the optimal position offset of OPC and optimal dispersion offset of fiber section are gradually increased as the WDM channel numbers are gradually increased. But, the optimal dispersion values of fiber sections per OPC position offset of 1 km are independent on WDM channel numbers, because the optimal position offset of OPC and optimal dispersion offset of fiber section are simultaneously increased as the WDM channel numbers are increased. It is also confirmed that the applying of these optimal parameter values is efficient to WDM system with many channels rather than WDM with small channels.
The implementation possibility of the flexible optical network configuration using the non-midway optical phase conjugator (OPC) in the dispersion-managed (DM) optical link for wavelength division multiplexed (WDM) transmission is demonstrated in this paper. It is confirmed that the implementation possibility of flexible link configuration is more increased, as number of fiber spans is more bigger and the residual dispersion per span (RDPS) is more large. It is also confirmed that the non-midway OPC link, in which RDPS of the latter half transmission section (after OPC) is decided by the averaged RDPS of the former half transmission section (before OPC), has more advantage for the flexible network configuration.
The data in automation and control systems can be achieved not only from different field devices but also from different OPC (OLE for Process Control) servers. However, current OPC clients can only read and decode the simple data from OPC servers. They will have some problems to acquire structured data and exchange the structured data. In addition to the large network control systems, the OPC clients can read, write, and subscribe to thousands of data points from/to OPC servers. Due to that, the most important factor for building a high performance and scalable industrial control system is the ability to transfer the process data between server and client in the most efficient and fastest way. In order to solve these problems, we propose a means to implement the OPC DA (Data Access) server supporting the OPC complex data, so that the OPC DA clients are able to read and decode any type of data from OPC servers. We also propose a method for caching the process data in large industrial control systems to overcome the limitation of performance of the pure OPC DA system. The performance analysis and discussion indicate that the proposed system has an acceptable performance and is feasible in order for applying to real-time industrial systems today.
In this article, the current technological state of OPC (Openness, Productivity, and Collaboration; formerly "OLE for Process Control") standards and the problem statement of these OPC standards are discussed. The development of an OPC clientserver framework for monitoring and control systems is introduced by using the new OPC Unified Architecture (UA) specifications, Service Oriented Architecture (SOA), web services, XML, etc. The developed framework in turn minimizes the efforts of developers in learning new techniques and allows system architects and designers to perform dependency analysis on the development of monitoring and control applications. The potential areas of the proposed framework and the redundancy strategies to increase the efficiency and reliability of the system are also represented according to the initial results from the system that was developed by the Visual Studio 2008 and OPC UA SDK.
The Journal of Korean Institute of Communications and Information Sciences
/
v.30
no.7A
/
pp.542-549
/
2005
In this paper, the optimal pump light power of optical phase conjugator (OPC) and the compensation characteristics of distorted WDM channel signals are numerically investigated, when the OPC with highly-nonlinear dispersion shifted fiber (HNL-DSF) not be placed at the mid-way of total transmission length. The total dispersion of former half section and latter half section is assumed to be same each other in this approach. It is confirmed that, in WDM transmission systems with OPC deviated from the mid-way, the pump light power for best compensation must be flexible selected depending on the OPC position. This optimal pump light power is gradually increased as the OPC is gradually closer to the receiver. Consequently, it is possible to establish the compensation system independent on the OPC position by setting optimal pump light power connected with the OPC position.
Proceedings of the Korea Society for Simulation Conference
/
2003.11a
/
pp.153-157
/
2003
전력연구원에서는 울진 표준형원전의 시뮬레이터를 개발하였으며, 여기에는 가상 주제어실, 발전소 현상 감시, 중대사고 등 많은 클라이언트 프로그램들이 있다. 이러한 프로그램들은 시뮬레이터와 연동되어 필요한 값을 읽고 쓰는 과정이 필요하다. 그러나 현재는 해당 시뮬레이터 환경에서 개발되지 않는 외부의 응용프로그램이 이들 시뮬레이터의 값들을 엑세스하는 방법은 제공하지 않고 있다. 본 보고서에서는 이러한 문제점을 해결하기 위해 외부 프로그램들이 시뮬레이션모델의 각종 변수들을 효과적으로 엑세스하여 값을 Read/write 할 수 있는 OPC (OLE for Process Control) Server를 개발하였다. 본 프로그램은 Rockwell의 OPC Server Toolkit인 RSI OPC/DDE Server Toolkit Library를 이용하여 개발하였으며 시뮬레이터가 실행되고 있는 컴퓨터에서 실행된다. 본 보고서에서는 OPC 일반개념, 개발한 OPC Server의 소개, OPC Server의 적용결과 등을 기술하고자 한다.
Proceedings of the Korea Information Processing Society Conference
/
2004.05a
/
pp.1323-1326
/
2004
본 연구에서는 OPC(OLE for Process Control)가 마이크로소프트의 COM(Component Object Model)과 DCOM(Distributed COM) 기술을 사용함으로써 윈도우즈 플랫폼에서 클라이언트 어플리케이션이 개발되어 져야 하는 제약을 해결하기 위하여 Java2OPC Gateway를 제안한다. Java2OPC Gateway는 프로세스 컨트롤 장비와 연결된 OPC 서버쪽과 통신하는 클라이언트의 기능과 다양한 플랫폼에서 프로세스 데이터에 접근하기 위한 자바 어플리케이션과 통신하는 서버의 기능을 가진다. 클라이언트 모듈은 C로 작성되고 서버 모듈은 Java로 작성되어 클라이언트 모듈과 서버 모듈은 JNI(Java Native Interface)로 연결 된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.