• 제목/요약/키워드: Opaque

검색결과 488건 처리시간 0.021초

Opaque 도재의 도포 방법이 치과용 합금과 도재간의 결합 강도에 미치는 영향 (EFFECT OF TWO OPAQUING TECHNIQUES ON METAL-CERAMIC BOND STRENGTH)

  • 장일성;이선형
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.475-488
    • /
    • 1996
  • The opaque porcelain layer of porcelain-fused-to-metal(PFM) restoration is critical for the success of PFM restoration because it is the first layer placed over the treated alloy. But, the methods of opaquing technique have not been confirmed. Usually, the one layer method and two layer method have been used for the application of opaque porcelain. In the past, alloys with porcelain veneers which have been used successfully have contained various precious metals. Recent increase in the cost of precious metals stimulates considerable interest in nonprecious alloys. Although nickel-chromium alloys and nickel-chromium-beryllium alloys have been widely used, the use of cobalt-chromium alloys would be gradually increased with elimination of any potential risk of nickel-related allergic responses and/or beryllium-related toxic responses. This investigation examined one- and two-layer opaque porcelain applications to determine the effect on the bond strength of titanium added cobalt-chromium metal ceramic alloy. Bond strength of Ceramco II porcelain to titanium added cobalt-chromium alloy(2Dentitan) and gold-platinum-palladium alloy(Degudent H) were evaluated by direct shear bond strength test with Instron universal testing machine. The results were as follows; 1. When the mean shear bond strength of each experimental group were compared in $0.25cm^2$ unit area, the titanium added cobalt-chromium alloy/two layer method exhibited the greatest strength(79.7kg), followed by titanium added cobalt-chromium alloy/one layer method(76.2kg), gold-platinum-palladium alloy/two layer method(71.4kg), gold-platinum-palladium alloy/one layer method(64.2kg). 2. No significant differences in bond strength were recorded between the two opaquing techniques for gold-platinum-palladium alloy and titanium added cobalt-chromium alloy. 3. No significant differences in bond strength were recorded between the gold-platinum-palladium alloy and the titanium added cobalt-chromium alloy.

  • PDF

X선관을 이용한 불투명한 물체 내부 유동의 정량적 가시화 연구 (Quantitative Flow Field Visualization of a Flow inside an Opaque Tube Using Angiographic PIV Method)

  • 김국배;임남윤;류재춘;임대현;이형구;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2935-2940
    • /
    • 2007
  • To diagnose circulatory diseases in the viewpoint of hemodynamics, we need to get quantitative hemodynamic information of blood flows related with the vascular diseases with high spatial resolution of tens micrometer and high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena, a new diagnosing technique combining medical radiography and PIV method was newly proposed and developed. This angiographic PIV technique consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for double pulses of X-ray, and a synchronizer. The feasibility of the angiographic PIV technique was tested and quantitative flow velocity field distribution of a flow inside an opaque conduit was acquired by the developed system. It can be used for measuring flow phenomena of nontransparent fluids inside opaque conduits.

  • PDF

Effects of Package Materials on Quality Change of Pine Bud Beverage Under Ultraviolet Light

  • An, Duek-Jun
    • Preventive Nutrition and Food Science
    • /
    • 제14권4호
    • /
    • pp.349-353
    • /
    • 2009
  • The effects of packaging materials on preserving the functional component of pine bud beverage stored under UV (ultraviolet) light exposure conditions were studied. The order of UV light blocking properties of the selected packages was: opaque can> opaque PET (polyethylene terepthalate) with green lamination=transparent PET with 10% PEN (polyethylene naphthalate) blending> transparent PET, and did not depend on film thickness in specified range. At 20${^{\circ}C}$, the order of preserving degree of original color and endobornyl acetate, which is quality index of pine bud beverage, was the same as above. Exposure to UV light can cause of deterioration of functional food components, but green color lamination and blending of PEN materials with transparent PET help to preserve the UV sensitive pine bud beverage components. However, the treated PET bottles have poorer preservation capabilities than the opaque cans. Transparent PET with PEN blending, in particular, will be very useful packaging material for colorful functional beverage preservation by helping to protect the ingredients while attracting consumer attention.

X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정 (Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF

불투명 수지재료의 복사에너지에 의한 변색 측정 (Measurement of Color Change of Opaque Resin Materials by Radiation Energy)

  • 한종성;김홍범;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.138-141
    • /
    • 1998
  • To evaluate the color change of the opaque resin materials, a measuring system including PAS(photodegradation acceleration system) was constructed. Xenon lamp is used as a light source in the PAS, and the radiant energy from the lamp is irradiated to the samples through serveral high-pass filters with cut-off wavelength in UV and visible region. The color difference of the samples were measured by using the measuring system with a spectrophotometer(CM-2002) and a computer. The result showed that the opaque resin materials changed severely in their color in the wavelength of UV region and changed a little in the wavelength of visible region.

  • PDF

도재용착용 Non beryllium 합금의 degassing과 opaque의 소성술식에 따른 결합강도 분석 (Shear bond strength analysis of non beryllium PFM metal with degassing and opaque firing techniques)

  • 임중재;이상혁
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4357-4363
    • /
    • 2015
  • 본 연구는 베릴륨 함유하지 않은 Ni-Cr계 도재용 금속에 전용도재를 도포, 소성된 시편을 3점 굴곡 시험으로 결합강도를 측정하고, SAM/EDS로 표면성분관찰 실험한 AVOVA와 Tukey HSAD 사후검정을 실시한 결과는 다음과 같은 결론을 얻었다. 첫째. 모든 군에서 ISO 9693의 치과용 금속-도재 시편의 최소 결합강도의 최소치인 25 MPa의 전단결합강도를 상위하며 안정적인 결과값을 나타냈다. 둘째. 결합 강도는 대조군 V1은 $32.37{\pm}1.91MPa$으로 나타났고, 실험군 V2 $38.25{\pm}1.38MPa$, 실험군 V3 $46.43{\pm}2.14MPa$, 그리고 실험군 V4 $47.21{\pm}1.72MPa$, 순으로 나타났으며 통계적으로 유의한 차이를 보였다. 사후 검정 (Tukey's HSD test) 결과, 결합강도 실험결과 실험군 V4는, 대조군 V1보다 높게 나타났다. 셋째. 금속-도재의 결합에서 산화처리를 시행한 군보다 시행하지 않고 불투명 도재를 도포하고 소성한 군이 높게 나타났으며, paste불투명 도재보다 분말 불투명도재의 사용에 따른 결합강도가 더 높게 나타났다. 넷째. 실험군 V4는 금속과 도재의 결합강도 비교에서 가장 높게 나타났다.

글리콜을 용매로 제조한 연고형 불투명 도재의 물성 (Manufacture of paste opaque porcelains using glycols as a solvent and evaluation of their physical properties)

  • 김사학
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.41-62
    • /
    • 2003
  • In this research, we manufactured the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent, and compared the composition of solvents, the coefficient of thermal expansion, the particle size distribution, the viscosity and bonding strength to metal, and the tone with those of the commercial products(Duceram Plus, Duceram GmbH; VMK 95, Vita Co.; Noritake EX-3, Noritake Co.)used in the clinical field. The results of the research were as follows: 1. The result of solvent analysis indicated that the solvents included in the paste opaque porcelains of the control group were mainly composed of Glycols. 2. From the Coefficient of thermal expansion measurement, we drew out the following results; testing group: $14.0\times10^{-6}/^{\circ}C$, Duceram Plus: $13.9\times10^{-6}/^{\circ}C$, VMK 95: $14.3\times10^{-6}/^{\circ}C$, and Noritake EX-3: $13.3\times10^{-6}/^{\circ}C$. 3. Seen from the result of particle size distribution measurement, the experimental group was similar to the control group in 1$\mu m$ below, but the experimental group marked the highest distribution of 61% in the case of between 1$\mu m$ and 5$\mu m$. Between 5$\mu m$ and 10$\mu m$, they showed relatively similar distribution, and Noritake EX-3 was turned out the highest distribution of 29% in 10$\mu m$ above. 4. From the result of viscosity measurement, Duceram plus showed the highest viscosity throughout all the measurements followed by Noritake Ex-3, experimental group and VMK 95 in decreasing order. 5. The result of bonding strength measurement was EX 35.53 $\beta\acute{A}$, DU 40.88 $\beta\acute{A}$, VM 39.43 $\beta\acute{A}$, and NO 35.39 $\beta\acute{A}$, and no significant difference was found between the experimental group and the control groups(P>0.05). 6. The measurement of the tone indicated that the $L^*$ value of the experimental group was 86.89 0.63 in average, which is higher than the control group in its brightness. In the case of the $a^*$ value, Duceram Plus, VMK 95 and EX-3 showed positive value, whereas the testing group was turned out negative value. In $b^*$ value, Duceram Plus proved the highest. From the results of this research, the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent did not make differences from the commercial products that are actually used in the clinical fields. Therefore, it is possible to utilize Propylene Glycol (PG) and Buthylene Glycol (BG) for the paste opaque porcelains of P.F.M crown. It is also recommended that further researches concerning the compositions and forms of powder, the types of organic solvent components and the ratio of mixture proceeded in order to improve the level of productivity in the future.

  • PDF

치과용도재에 의한 법랑질 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL)

  • 이영국;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

Effect of repetitive firing on passive fit of metal substructure produced by the laser sintering in implant-supported fixed prosthesis

  • Altintas, Musa Aykut;Akin, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.167-172
    • /
    • 2020
  • PURPOSE. The aim of the present study was to investigate the passive fit of metal substructure after repetitive firing processes in implant-supposed prosthesis. MATERIALS AND METHODS. Five implants (4 mm diameter and 10 mm length) were placed into the resin-based mandibular model and 1-piece of screw-retained metal substructure was produced with the direct metal laser sintering (DMSL) method using Co-Cr compound (n = 10). The distance between the marked points on the multiunit supports and the marginal end of the substructure was measured using a scanning electron microscope (SEM) at each stage (metal, opaque, dentin, and glaze). 15 measurements were taken from each prosthesis, and 150 measurements from 10 samples were obtained. In total, 600 measurements were carried out at 4 stages. One-way ANOVA test was used for statistical evaluation of the data. RESULTS. When the obtained marginal range values were examined, differences between groups were found to be statistically significant (P<.001). The lowest values were found in the metal stage (172.4 ± 76.5 ㎛) and the highest values (238.03 ± 118.92 ㎛) were determined after glaze application. When the interval values for groups are compared with pairs, the differences between metal with dentin, metal with glaze, opaque with dentin, opaque with glaze, and dentin with glaze were found to be significant (P<.05), whereas the difference between opaque with metal was found to be insignificant (P=.992). CONCLUSION. Passive fit of 1-piece designed implant-retained fixed prosthesis that is supported by multiple implants is negatively affected by repetitive firing processes.

기계시각을 이용한 현미의 개체 품위 판별 알고리즘 개발 (Algorithm for Discrimination of Brown Rice Kernels Using Machine Vision)

  • 노상하;황창선;이종환
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.295-302
    • /
    • 1997
  • An ultimate purpose of this study was to develop an automatic system for brown rice quality inspection using image processing technique. In this study emphasis was put on developing an algorithm for discriminating the brown rice kernels depending on their external quality with a color image processing system equipped with an adaptor magnifying the input image and optical fiber for oblique lightening. Primarily, geometical and optical features of images were analyzed with paddy and the various brown rice kernel samples such as a sound, cracked, peen-transparent, green-opaque, colored, white-opaque and brokens. Secondary, geometrical and optical parameters significant for identifying each rice kernels were screened by a statistical analysis(STEPWISE and DISCRIM procedure, SAS wer. 6) and an algorithm fur on- line discrimination of the rice kernels in static state were developed, and finally its performance was evaluated. The results are summarized as follows. 1) It was ascertained that the cracked kernels can be detected when e incident angle of the oblique light is less than 2$0^{\circ}C$ but detectivity was significantly affected by the angle between the direction of the oblique light and the longitudinal axis of the rice kernel and also by the location of the embryo with respect to the oblique light. 2) The most significant Parameters which can discriminate brown rice kernels are area, length and R, B and r values among the several geometrical and optical parameters. 3) Discrimination accuracies of the algorithm were ranged from 90% to 96% for a sound, cracked, colored, broken and unhulled, about 81 % for green-transparent and white-opaque and 75 % for green-opaque, respectively.

  • PDF