• Title/Summary/Keyword: One-chip

Search Result 1,243, Processing Time 0.03 seconds

Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods (비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The aim of this study is to develop a label-free immunosensor for microbial detection and to evaluate its applicability to Pseudomonas aeruginosa detection in various food samples. The antibodies used were a polyclonal antiserum from rabbit (polyvalent type) and a monoclonal antibody raised against the flagella of P. aeruginosa. Antibody immobilization was done by a thiolated antibody chemisorption onto one gold electrode of a piezoelectric quartz crystal with a thiol-cleavable, heterobifunctional cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. To the Stomacher-treated samples from various raw and processed foods under cold storage, comprising sirloin, cod and pettitoes, spiking and enrichment culture were done to prepare the model samples, followed by the measurements of the frequency shifts after sample injections. The frequency shifts obtained by the sample matrices themselves were in the range of 52~89 Hz. The injections of the spiked samples caused the frequency shifts of 108~200 Hz, whereas the enriched samples decreased the steady-state resonant frequencies by 162~222 Hz. All sample measurements including baseline stabilization, sample injection and acquisition of the steady-state response were accomplished within 30 min.

The Effect of Tomographic Angles on the Osteophytic Lesion Detectability of the Mandibular Condyle (단층촬영 각도의 변화가 하악과두의 골 증식성 병소의 인식에 미치는 영향)

  • Han Sang-Sun;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.309-325
    • /
    • 1999
  • Purpose: To find out the effects that different tomographic angles have on the osteophytic lesion detectability of condyle head by comparison the individualized lateral tomographic image with the various tomographic angled images using SCANORA/sup (R)/. Materials & Methods: This study is performed to simulate osteophytic lesions by a series of dentin chips placed at six locations on condyle head. The control angle is 15° and from this angle. tomographic angle were varied with -10°, +10°, +20°. All the images with each sized dentin chip were scored by three dental radiologists with the use of confidence levels for presence or absence of the lesion, each examiner viewed one of the images twice. A rating scale from 0 to 2 (0, lesion definitely not present; 1. uncertain if lesion is present; 2, lesion definitely present). Responses were assessed by Tukey' s multiple comparison method and kappa value. Results: 1. The lesion size of 0.3 mm could not be detected in all the tomographic angles. As the size of the lesion increased the average value of lesion detectability also increased. 2. In the lesion sizes of 0.7 mm there was statistically significant difference between the 15° control angle and the altered tomographic angles (p<0.05). In 1.0 mm lesion there was no significant difference in the ±10° altered angles (p >0.05). but there was significant difference in the altered angle (p<0.05). In the lesion sizes of 0.3 mm and 2.0 mm there was no significant difference between the 15° control angle and all the altered angles (p >0.05). 3. In the anteromedial. anterosuperior, anterolateral area there was no significant difference between the 15° control angle and the ±10° altered angle (p >0.05), but in the comparison with the +20° altered angle there was significant difference (p<0.05). Conclusion: When imaging the lateral tomography of the temporomandibular joint used by SCANORA/sup (R)/, it can be considered that in the osteophytic lesion size of 2 mm and above, the tomographic angle difference within +20° to the horizontal angle of the condyle. has little effect on the lesion detectability. And in the lesion size of 1 mm, the altered angle within ±10° also has little effect on the lesion detectability.

  • PDF

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.

A Micro Fluxgate Magnetic Sensor with Closed Magnetic Path (폐자로를 형성한 마이크로 플럭스게이트 자기 센서)

  • 최원열;황준식;강명삼;최상언
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.19-23
    • /
    • 2002
  • This paper presents a micro fluxgate magnetic sensor in printed circuit board (PCB). In order to observe the effect of the closed magnetic path, the magnetic cores of rectangular-ring and two bars were each fabricated. Each fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ~100,000. Four outer layers as an excitation and pick-up coils have a planar solenoid and are made of copper foil. In case of the fluxgate sensor having the rectangular-ring shaped core, excellent linear response over the range of -100 $\mu$T to + 100 $\mu$T is obtained with 540 V/Tsensitivity at excitation square wave of 3 $V_{p-p}$ and 360 KHz. The chip size of the fabricated sensing element is $7.3 \times 5.7\textrm{mm}^2$. The very low power consumption of ~8 mW was measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.n.

  • PDF

Memory Reduction of IFFT Using Combined Integer Mapping for OFDM Transmitters (CIM(Combined Integer Mapping)을 이용한 OFDM 송신기의 IFFT 메모리 감소)

  • Lee, Jae-Kyung;Jang, In-Gul;Chung, Jin-Gyun;Lee, Chul-Dong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.10
    • /
    • pp.36-42
    • /
    • 2010
  • FFT(Fast Fourier Transform) processor is one of the key components in the implementation of OFDM systems for many wireless standards such as IEEE 802.22. To improve the performances of FFT processors, various studies have been carried out to reduce the complexities of multipliers, memory interface, control schemes and so on. While the number of FFT stages increases logarithmically $log_2N$) as the FFT point-size (N) increases, the number of required registers (or, memories) increases linearly. In large point-size FFT designs, the registers occupy more than 70% of the chip area. In this paper, to reduce the memory size of IFFT for OFDM transmitters, we propose a new IFFT design method based on a combined mapping of modulated data, pilot and null signals. The proposed method focuses on reducing the sizes of the registers in the first two stages of the IFFT architectures since the first two stages require 75% of the total registers. By simulations of 2048-point IFFT design for cognitive radio systems, it is shown that the proposed IFFT design method achieves more than 38.5% area reduction compared with previous IFFT designs.

A Propose on the Propagation Prediction Model for Service in the Sea of CDMA Mobile Communication (CDMA 이동통신의 해상 서비스를 위한 전파예측모델 제안)

  • Kim, Young-Gon;Park, Chang-Kyun
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.38 no.6
    • /
    • pp.106-112
    • /
    • 2001
  • Unfortunately, the area without economical efficiency, especially the far distance sea, is much lower than that of a urban area-built-up area. It should be promoted the equivalent level to a urban area in the light of future-oriented universal service. Actually, Because propagation environment of mobile communication in the sea is greatly different from that for inland focused on built-up area, a propagation prediction model in the sea should be distinguished from inland-based one. Accordingly, the purpose of this study is to suggest the propagation prediction model for the sea service as a method to minimize unnecessary facilities investment and maintenance caused by additional or new building of a base station. If mobile phone service for far distance sea is provided by expanding limited communication zone of narrow band CDMA mobile communication whose spread band FA is 1.2288MHz. Suggested propagation prediction model includes five parameters to minimize facilities investment of a base station and maximize channel capacity: equivalent line of sight, chip delay by PN code, antenna altitude, power of base station and gain of antennas. Finally, suggested propagation prediction model is simulated and, the results are examined for its utility by comparing with loss of free space.

  • PDF

A study on the characteristic of Pockel cell Q-switch for Nd:YAG laser (Nd:YAG Laser를 위한 포켓셀 Q-스위치특성 연구)

  • Kim, Whi-Young
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • The Q-switching the shutter or the different optical science element puts in within the laser light resonator and the storehouse departs from the within the resonator it loses the mortar and the reversal distribution which when is sufficient creates from within the active medium, opens the shutter instantaneously and it is to do to be made to emit with the light where the energy which is accumulated within the resonator is strong very. Like this Q-switching of laser resonator--It decreases factor increasing suddenly to make. To method of Laser Q-switching mechanical switching methods, electro-optic switching methods and switching by saturable absorber methods, acousto-optic switching method etc. 4 kind are being used on a large scale. In these people the conversion which is electric in compliance with the effect which is electrooptics is widely being used the Q-switching pulse of short pulse width because being it will be able to create. Consequently, Pockel cell where it has the quality of electrooptics effect) the Q-it is become known that it is suitable it uses with switch. From the research which it sees FET and one-chip microprocessor where it is a switching element and pulse transfomer to plan and produce pockel cell Q-switch driving gears, pulse style Nd: It applied in YAG Laser system and it investigated and researched the operating characteristic of the Q-switch. Also, the Q-switch leads and Nd where it is output: YAG with forecast in compliance with a theoretical calculation it comes to buy laser beam side politics it compared and laser beam qualities which had become Q-switching it analyzed.

  • PDF

Implementation of Improved Frame Slotted ALOHA Algorithm for Fast Tag Collection in an Active RFID System (고속 태그 수집을 위한 개선된 능동형 RFID 시스템용 프레임 Slotted ALOHA 알고리즘 구현)

  • Kim, Ji-Tae;Kang, Byeong-Gwon;Lee, Kang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.9
    • /
    • pp.598-605
    • /
    • 2014
  • In this paper, we suggest a modified slotted ALOHA algorithm for fast tag collection in active RFID system and implement the reader and tag operation using CC2530 chip of Texas Instruments Co. to prove the performance of the proposed algorithm. In the present international standard related with active RFID including ISO/IEC 18000-7 the reader sends sleep command to each tag after successful obtaining tag's information. Meanwhile, in this paper, the tags decide to sleep after checking the second command from the reader resulting in enormously decreased tag collection time. We tested the proposed algorithm with 30 tags over the range of 0-3m and the results showed that the tag collection process was completed in 400msec at average. And 30 tags are collected in one second with 99.7% and the collection rate is 100% in 2m distance between reader and tag. The collection rates are 99.94% and 99.7% for distance 2.5m and 3m, respectively. The average collection rate is 99.91% over all range and it is concluded that the proposed algorithm is enough to apply to real fields.

A Study on the Development of Urine Analysis System using Strip and Evaluation of Experimental Result by means of Fuzzy Inference (스트립을 이용한 요분석시스템의 개발과 퍼지추론에 의한 검사결과 평가에 관한 연구)

  • Jun, K. R.;Lee, S. J.;Choi, B. C.;An, S. H.;Ha, K.;Kim, J. Y.;Kim, J. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.477-486
    • /
    • 1998
  • In this paper, we implemented the urine analysis system capable of measuring a qualitative and semi-quantitative and assay using strip. The analysis algorithm of urine analysis was adopted a fuzzy logic-based classifiers that was robust to external error factors such as temperature and electric power noises. The spectroscopic properties of 9 pads In a strip were studied to developing the urine analysis system was designed for robustnesss and stability. The urine analysis system was consisted of hardware and software. The hardware of the urine analysis system was based on one-chip microprocessor, and Its peripherals which composed of optic modulo, tray control, preamplifier, communication with PC, thermal printer and operating status indicator. The software of the urine analysis system was composed of system program and classification program. The system program did duty fort system control, data acquisition and data analysis. The classification program was composed of fuzzy inference engine and membership function generator. The membership function generator made triangular membership functions by statical method for quality control. Resulted data was transferred through serial cable to PC. The transferred data was arranged and saved be data acquisition program coded by C+ + language. The precision of urine analysis system and the stability of fuzzy classifier were evaluated by testing the standard urine samples. Experimental results showed a good stability states and a exact classification.

  • PDF

Design of a 48MHz~1675MHz Frequency Synthesizer for DTV Tuners (DTV 튜너를 위한 48MHz~1675MHz 주파수합성기 설계)

  • Ko, Seung-O;Seo, Hee-Teak;Kwon, Duck-Ki;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1125-1134
    • /
    • 2011
  • In this paper a wideband frequency synthesizer is designed for DTV tuners using a $0.18{\mu}m$ CMOS process. It satisfies the DTV frequency band(48~1675MHz). A scheme is proposed to cover the full band using only one VCO and reliable broadband characteristics are achieved by reducing the variations of VCO gains and frequency steps. The simulation results show that the designed VCO has frequency range of 1.85~4.22GHz, phase noise at 4.22GHz of -89.7dBc/Hz@100kHz, gains of 62.4~95.8MHz/V(${\pm}21.0%$) and frequency steps of 22.9~47.9MHz(${\pm}35.3%$). The designed VCO has a phase noise of -89.75dBc/Hz at 100kHz offset. The designed synthesizer has a lock time less than $0.15{\mu}s$. The measured VCO tuning range is 2.05~3.4GHz. The frequency range is shifted down but still satisfy the target range owing to the design for enough margin. The designed circuit consumes 23~27mA from a 1.8V supply, and the chip size including PADs is $2.0mm{\times}1.5mm$.