• 제목/요약/키워드: One-bottle adhesive system

검색결과 17건 처리시간 0.018초

단일용기 상아질 접착제 처리 후 레진-상아질 경계면에 대한 투과전자현미경적 연구 (A TEM STUDY OF THE RESIN-DENTIN INTERDIFFUSION ZONE FORMED BY ONE-BOTTLE DENTIN ADHESIVE SYSTEMS)

  • 양동운;박성호;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.180-192
    • /
    • 2000
  • One bottle system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. There has been many studies to measure the bond strength of one bottle systems but no actual work has been done on micromorphologic study of resin-dentin interdiffusion zone after one bottle system application. To evaluate the bonding patterns of various commercially available one bottle systems to dentin, observation of resin-dentin interdiffusion zone under TEM was performed. Caries-free human third molars within one month of extractions were chosen for the experiments. The molars were sectioned 1mm above the cementoenamel junction and got rid of the root portions. Crown portions of the teeth were sectioned parallel to occlusal surface so that dentin discs of 1mm in thickness were remained. 7 one bottle systems and 1 two bottle system were applied according to manufacturer's instructions and followings were the results. 1. In every experimental groups, cross bandings of collagen fiber were distinguishable and tight bon dings between the bonding agents and dentin were observed. 2. Hybrid layer was clearly observed in ONE-STEP$^{(R)}$, Prime & Bond$^{(R)}$ 2.1, Syntac$^{(R)}$ SC, MAC-BOND II groups but it was not clear in Single Bond, D-Liner Dual PLUS, ONE COAT BOND groups. 3. Electron-density of hybrid layer was uniform in pattern in MAC-BOND II, Prime & Bond$^{(R)}$ 2.1 groups but not so uniform in ONE-STEP$^{(R)}$ group. 4. Electron-dense amorphous phase in most superior layer of the resin-dentin interdiffusion zone was characteristically observed in Single Bond, Syntac$^{(R)}$ SC, ONE COAT BOND groups. It can be concluded that bondings between the dentin bonding agents and dentin can be various in pattern according to their chemical compositions and the condition during applications.

  • PDF

One-Bottle system 상아질접착제의 전단결합강도 해석 (SHEAR BOND STREGNTHS OF ONE-BOTTLE DENTIN ABHESIVE SYSTEMS)

  • 조병훈;임성삼;권혁춘;엄정문;손호현;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.546-553
    • /
    • 1999
  • In Older to evaluate the effectiveness of 'One-bottle dentin adhesive system', the shear bond strengths of two fourth generation dentin adhesive systems and two One-bottle systems to the occlusal dentin of the freshly extracted third molars were measured by the regulation of the ISO TR 11405. The fourth generation dentin adhesive systems used in this study were Scotchbond Multi-Purpose Plus and All-Bond 2, and the One-bottle systems were Single Bond and One-Step. The effects of the thickness of hybrid layer and adhesive layer, the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule were analyzed as the contributing factors of the shear bond strength of dentin bonding systems from the Scanning Electron Microscopic images. The results were as follows: 1. The shear bond strengths of Scotchbond Multi-Purpose, All-Bond 2, and Single Bond were 16.98${\pm}$3.40 MPa, 15.10${\pm}$2.77 MPa and 15.05${\pm}$3.18 MPa, respectively. There were no statistical differences(p>0.05). 2. But, the shear bond strength of One-Step were significantly lower than those of the other groups (11.81${\pm}$1.95 MPa, p<0.05). 3. The thicknesses of hybrid layer and adhesive layer of One-Step were significantly thinner than those of the other groups(p<0.05). The differences of the diameter of resin tag(p=0.0685) and the ratio between the diameter of resin tag and that of dentinal tubule(p=0.2401) were not significant among all the material groups. 4. The thickness of hybrid layer and adhesive layer might be considered as contributing factors of the she at bond strengths of dentin bonding systems, but the diameter of resin tag and the ratio between the diameter of resin tag and that of dentinal tubule might not.

  • PDF

수종의 One-bottle 상아질 결합제의 전단 결합 강도에 관한 연구 (THE STUDY ON SHEAR BOND STRENGTHS OF VARIOUS ONE-BOTTLE DENTIN ADHESIVES)

  • 오소희;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.553-565
    • /
    • 2001
  • 새로운 상아질 결합제인 5세대 상아질 결합제는 산 부식, 전 처치, 그리고 접착의 복잡한 과정을 줄여줌으로써 시술 과정이 간단하고 시간이 단축되며 시술 도중의 오염에 대한 가능성을 줄여준다는 점에서 유용성이 부각되고 있다. One-bottle 상아질 결합제에 관한 기존의 연구들이 아세톤, 에탄올 등의 용매를 포함하는 상아질 결합제를 중심으로 이루어져 본 실험에서는 water-based 상아질 결합제를 우치(牛齒)의 상아질에 적용하여 얻어지는 상아질 결합력을 전단 결합 강도 측정과 주사 전자현미경 관찰을 통해 다음과 같은 결론을 얻었다. 1. 전단결합강도의 측정결과 II군 IV군, I군, III군의 순서로 II군에서 다소 높은 전단강도를 보였으나, 모든 군들간에는 유의 차가 없었다(p>0.05). 2. 주사 전자 현미경 소견에서 II군과 IV군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며 레진 테그의 측방 가지 또한 다수 관찰할 수 있었다.

  • PDF

One-Bottle 상아질 결합제의 유치 상아질에 대한 전단 결합 강도에 관한 연구 (SHEAR BOND STRENGTH OF "ONE-BOTTLE ADHESIVE" SYSTEM IN PRIMARY DENTIN.)

  • 김종빈;김종수
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.444-456
    • /
    • 2000
  • 치아 교환시기에 발거된 치관이 건전한 유구치 상아질 표면을 One-Bottle 상아질 결합제인 Primer & Bond NT(DeTrey/Dentsply, Konstanz, Germany)와 Single Bond(3M Co. U.S.A.) 그리고 대조군으로 Scotchbond Multipurpose System(3M Co. U.S.A.)를 이용하여 각 제조자의 지침에 따라 처리하여 레진을 충전하고 광중합하였다. 1. 전단 결합 강도의 측정결과 Primer & Bond NT군인 1군, Single Bond군인 2군, 그리고 대조군으로 사용된Scotchbond Multipurpose System군인 3군의 순서로 1군에서 다소 높은 전단 결합 강도를 보였으나, 모든 군들간에는 통계적 유의차가 없었다(p>.05). 2. 주사 전자현미경 소견에서 1군 2군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며, 레진 테그와 측방 가지 또한 다수 관찰되었다. 반면 3군에서는 혼화층이나 측방가지의 형성이 1, 2군에 비해 다소 미약한 양상을 보였다.

  • PDF

제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가 (A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES)

  • 김형수;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

타액 오염이 One bottle 상아질 결합제의 전단결합강도에 미치는 영향에 관한 연구 (A STUDY ON THE EFFECT OF SALIVA CONTAMINATION ON THE BOND STRENGTH OF ONE-BOTTLE ADHESIVE SYSTEM)

  • 전형준;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.566-574
    • /
    • 2001
  • 법랑질과 상아질에 대한 접착시스템의 결합력은 타액이나 혈액에 의하여 저하될 수 있다. 제 5세대 상아질 결합제 적용시에 산부식된 치면이 타액에 오염될 경우, 보다 효율적인 치면 처리 방법을 알아보기 위해 여러 가지 치면 처리 방법과 조건을 설정한 다음 수복물의 유지력을 전단결합강도 측정으로 서로 비교 분석하고, 치아와 수복물 사이의 계면을 주사전자 현미경을 이용해 관찰하였다. 그 결과 우치상아질의 산부식후 타액오염된 경우, 물로 10초간 세척한 후 공기로 가볍게 건조하여 수복하면 전단결합강도의 감소가 일어나지 않았으나, Prime & Bond NT의 광중합후에 타액오염된 경우에는 물로 10초간 세척한 후 공기로 완전히 건조를 하여도 레진과의 결합력이 매우 약해지며 Prime & Bond NT를 재적용하더라도 전단결합강도의 상당한 감소를 보였으며, 주사전자 현미경 관찰결과 모든 군에서 유사한 혼화층과 레진태그의 형성을 보였으며 특이할만한 각 군간의 차이를 관찰할 수 없었다.

  • PDF

All-in-one adhesive를 이용한 치면열구전색술식이 전색재의 미세누출에 미치는 영향에 대한 연구 (THE EFFECT OF SEALING PROCEDURE USING ALL-IN-ONE ADHESIVE ON MICROLEAKAGE OF PIT AND FISSURE SEALANT)

  • 윤희훈;이재천;김정욱;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제31권3호
    • /
    • pp.486-494
    • /
    • 2004
  • 본 연구는 all-in-one adhesive를 사용하여 전색하는 술식을 통상적인 탈회 술식 및 single-bottle 결합제를 이용하여 전색하는 술식과 비교하여 법랑질과 전색재 사이의 미세누출의 차이를 알아보고자 하는 것이다. 75개의 제3대구치를 5군으로 나누어 1군을 대조군으로 하여 only Etching(1군), $Adper^{TM}$ Single $Bond^{TM}$(2군), $Adper^{TM}\;Prompt^{TM}$ L-Pop(3군), Ad-bond(4군), One-up bond F(5군)로 처리한 후 전색재 도포 후 열순환을 시 행한 뒤 미세누출도를 검사하여 다음과 같은 결론을 얻었다. 1. All-in-one adhesive를 사용한 3, 4, 5군은 1군에 비해 유의성 있게 높은 평균미세누출도를 보였다(p<0.05). 2. 가장 낮은 평균미세누출도는 2군(0.14)에서 보였고 1군(1.05), 3군(1.65), 4군(2.85), 5군(3.05) 순으로 증가하였다. 3. All-in-one adhesive를 사용한 3, 4, 5군중에서 3군은 4, 5군에 비해 통계적으로 유의성 있게 낮은 평균미세누출 도를 보여주었지만(p<0.05) 1군과 2군에 비해 유의성 있게 높은 평균값을 보여주었다(p<0.05). 4. 4군과 5군 사이의 평균미세누출도는 통계적으로 유의성 있는 차이를 보이지 않았다(p>0.05). 5. 주사전자현미경관찰결과 all-in-one adhesive를 사용한 3, 4, 5군은 1, 2군에 비해 레진돌기가 짧고 불규칙하게 관찰되었다.

  • PDF

Micro-shear bond strength of resin-bonding systems to cervical enamel.

  • Shimada, Y.;Kikushima, D.;Iwamoto, N.;Shimura, R.;Ide, T.;Nakaoki, Y.;Tagami, J.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.560.1-560
    • /
    • 2001
  • To evaluate the micro-shear bond strength of current adhesive systems to cervical and mid-coronal enamel. Materials and Two commercially available resin adhesives were investigated; a self-etching primer system(Clearfil SE Bond, Kyraray) and a one-bottle adhesive system(Single Bond, 3M) intended for use with the total-etch wet-bonding technique were employed. Two regions of enamel, cervical and mid-coronal regions, were chosen from the buccal surface of extracted molars and were then bonded with each adhesive system and submitted to the micro-shear bond test.(중략)

  • PDF

수 종의 복합레진 접착 시스템에서의 미세 누출의 비교 (COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS)

  • 석충기;남동우;남순현;김영진;김현정
    • 대한소아치과학회지
    • /
    • 제31권4호
    • /
    • pp.636-644
    • /
    • 2004
  • 최근 자가 부식형 접착 시스템이 개발되어 법랑질 및 상아질에 모두 적용할 수 있고, 임상적 술식을 단순화 시켰다. 이 접착 시스템은 적용하기 용이하고 임상적으로도 법랑질 및 상아질에 높은 결합강도를 보인다고 보고되고 있다. 이 연구는 in vitro 상에서 복합레진 5급 와동의 법랑질 및 상아질 경계에서 전부식 처리를 동반한 one-bottle 접착시스템과 자가 부식형 접착 시스템을 사용하였을 때 미세 누출을 비교하기 위해 시행하였다. 교정적 목적으로 발치된 30개의 소구치를 무작위적으로 3개 군으로 나누었다; 1 군 (Single $Bond^{(R)}$ + Filtek $Z250^{(R)}$), 2 군 (Clearfil SE $Bond^{(R)}$ + Filtek $Z250^{(R)}$), 3 군 (Adper Prompt $L-Pop^{(R)}$ + Filtek $Z250^{(R)}$). 표준화된 5급 와동을 각 소구치 협면, 설면에서 백악-법랑경계에 평행하게 형성하였으며, 와동의 치은측 1/2은 백악법랑경계보다 1mm 치근단으로 연장하였다. 접착 시스템을 제조자의 지시대로 적용한 다음 복합레진을 충전하고 제조자의 지시대로 광중합하였다. 시편을 $37^{\circ}C$ 증류수에 5일 간 보관 후 $5^{\circ}C{\pm}2^{\circ}C$$55^{\circ}C{\pm}2^{\circ}$에서 1000회 열순환한 다음, 2% methylene blue 용액에 12시간 침잠시켰다. $Isomet^{TM}$ (Buehler Co., Lake Bluff, IL, USA)을 사용하여 치아를 충전물 중앙에서 종절단한 후 입체 현미 경하에서 25배의 배율로 색소 침투도를 평가하였다. 결과는 t-test 와 one-way ANOVA를 이용하여 통계처리 하였다. 결과는 다음과 같았다. ${\cdot}$ 실험에 사용 된 접착 시스템 중에 미세 누출을 완벽하게 방지하는 접착 시스템은 없었다. ${\cdot}$ 상아질 경계에서의 미세 누출이 법랑질 경계에서보다 통계학적으로 유의하게 더 많았다(p<0.0001). ${\cdot}$ 법랑질 경계에서 자가 부식형 접착 시스템은 전부식 처리를 동반한 one-bottle접착 시스템과 통계학적으로 유의한 차이를 보이지 않았다. ${\cdot}$ 상아질 경계에서, 자가 부식형 접착 시스템은 전부식 처리를 동반한 one-bottle 접착 시스템과 통계학적으로 유의한 차이를 보이지 않았다.

  • PDF

상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구 (A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT)

  • 남기영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.