THE EFFECT OF SEALING PROCEDURE USING ALL-IN-ONE ADHESIVE ON MICROLEAKAGE OF PIT AND FISSURE SEALANT

All-in-one adhesive를 이용한 치면열구전색술식이 전색재의 미세누출에 미치는 영향에 대한 연구

  • Yoon, Hee-Hun (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
  • Lee, Jae-Cheon (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
  • Kim, Jjung-Wook (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
  • Kim, Chong-Chul (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
  • Hahn, Se-Hyun (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
  • Lee, Sang-Hoon (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University)
  • 윤희훈 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 이재천 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 김정욱 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 김종철 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 한세현 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
  • 이상훈 (서울대학교 치과대학 소아치과학교실 및 치학연구소)
  • Published : 2004.08.31

Abstract

The purpose of this study was to examine differences in microleakage of enamel-sealant interface when all-in-one adhesives were used compared with conventional acid etching and single-bottle adhesive system. Seventy-five extracted permanent third molars were randomly divided into 5 groups and treated with only Etching, $Adper^{TM}\;Single\;Bond^{TM}\;Adper^{TM}\;Prompt^{TM}$ L-Pop, AQ-bond and One-up Bond F each. After sealant application, the samples were thermocycled and the degree of microleakage was determined. The results were as follows : 1. Group 3, 4, 5 using the all-in-one adhesive system showed significantly higher microleakage score than Group 1(p<0.05). 2. The lowest mean microleakage score was Group 2(0.41) followed by Group 1(1.05) Group 3(1.65), Group 4(2.85) and Group 5(3.05). 3. Among Groups using all-in-one adhesives, Group 3 showed significantly lower mean microleakage score than the other groups(p<0.05) but showed significantly higher mean score than both Group 1 and Group 2(p<0.05). 4. There was no statistically significant difference(p>0.05) between Group 4 and Group 5. 5. In SEM examination, all the groups used all-in-one adhesive showed shorter resin tags than Group 1.

본 연구는 all-in-one adhesive를 사용하여 전색하는 술식을 통상적인 탈회 술식 및 single-bottle 결합제를 이용하여 전색하는 술식과 비교하여 법랑질과 전색재 사이의 미세누출의 차이를 알아보고자 하는 것이다. 75개의 제3대구치를 5군으로 나누어 1군을 대조군으로 하여 only Etching(1군), $Adper^{TM}$ Single $Bond^{TM}$(2군), $Adper^{TM}\;Prompt^{TM}$ L-Pop(3군), Ad-bond(4군), One-up bond F(5군)로 처리한 후 전색재 도포 후 열순환을 시 행한 뒤 미세누출도를 검사하여 다음과 같은 결론을 얻었다. 1. All-in-one adhesive를 사용한 3, 4, 5군은 1군에 비해 유의성 있게 높은 평균미세누출도를 보였다(p<0.05). 2. 가장 낮은 평균미세누출도는 2군(0.14)에서 보였고 1군(1.05), 3군(1.65), 4군(2.85), 5군(3.05) 순으로 증가하였다. 3. All-in-one adhesive를 사용한 3, 4, 5군중에서 3군은 4, 5군에 비해 통계적으로 유의성 있게 낮은 평균미세누출 도를 보여주었지만(p<0.05) 1군과 2군에 비해 유의성 있게 높은 평균값을 보여주었다(p<0.05). 4. 4군과 5군 사이의 평균미세누출도는 통계적으로 유의성 있는 차이를 보이지 않았다(p>0.05). 5. 주사전자현미경관찰결과 all-in-one adhesive를 사용한 3, 4, 5군은 1, 2군에 비해 레진돌기가 짧고 불규칙하게 관찰되었다.

Keywords