• Title/Summary/Keyword: One-Wire

Search Result 863, Processing Time 0.031 seconds

A CDMA Network-based Wireless System for Measuring Lap Time on a Ski Slope (CDMA 망에 기반한 스키장 슬로프의 무선 구간 기록 측정 시스템)

  • Lee, Hyung-Bong;Park, Lae-Jeong;Moon, Jung-Ho;Chung, Tae-Yun
    • The KIPS Transactions:PartD
    • /
    • v.16D no.1
    • /
    • pp.133-138
    • /
    • 2009
  • This paper introduces a pilot CDMA network-based wireless lap time measurement system set up on a ski slope of Yongpyong Ski Resort. The wireless lap time measurement system is one output of U-Sports Project of Gangwon Province, which is intendended for promoting local strategic business and preparation for hosting 2018 Winter Olympic Games at Pyeongchang. A pair of laser sensors is installed at the entry and exit points of a section requiring lap time measurement on a ski slope. Each laser sensor is connected to a sensor node via wire so that the sensor node can detect the time when a skier enters or exits the section. Also each sensor node is connected to a CDMA network via a modem and receives a standard time from a NTP server. Each node executes the NTP algorithm to synchronize its local time to the received server time. As a result of the time synchronization, the sensor nodes maintain its local time within a resolution of at least 10 miliseconds and transmit the time of detection to a central control center. While the wireless lap time measurement system introduced in the paper does not need expensive measurement equipment, the system allows the central control center to provide lap time records in a more convenient manner compared to conventional manual lap time measuremnt methods.

A Study for Detecting Fuel-cut Driving of Vehicle Using GPS (GPS를 이용한 차량 연료차단 관성주행의 감지에 관한 연구)

  • Ko, Kwang-Ho
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.207-213
    • /
    • 2019
  • The fuel-cut coast-down driving mode is activated when the acceleration pedal is released with transmission gear engaged, and it's a default function for electronic-controlled engine of vehicles. The fuel economy becomes better because fuel injection stops during fuel-cut driving mode. A fuel-cut detection method is suggested in the study and it's based on the speed, acceleration and road gradient data from GPS sensor. It detects fuel-cut driving mode by comparing calculated acceleration and realtime acceleration value. The one is estimated with driving resistance in the condition of fuel-cut driving and the other is from GPS sensor. The detection accuracy is about 80% when the method is verified with road driving data. The result is estimated with 9,600 data set of vehicle speed, acceleration, fuel consumption and road gradient from test driving on the road of 12km during 16 minutes, and the road slope is rather high. It's easy to detect fuel-cut without injector signal obtained by connecting wire. The detection error is from the fact that the variation range of speed, acceleration and road gradient data, used for road resistance force, is larger than the value of fuel consumption data.

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS (법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향)

  • Koo, Bong-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.452-459
    • /
    • 2006
  • Competition will usually develop between the opposing walls as the restorative resin shrinks during polymerization. Magnitude of this phenomenon may be depended upon cavity configuration and volume. The purpose of this sturdy was to evaluate the effect of cavity configuration and volume on microleakage of composite resin restoration that has margins on the enamel site only. The labial enamel of forty bovine teeth was ground using a model trimmer to expose a flat enamel surface. Four groups with cylindrical cavities were defined, according to volume and configuration factor(Depth x Diameter / C-factor) - Group I : 1.5 mm ${\times}$ 2.0 mm / 4.0, Group II : 1.5 mm ${\times}$ 6.0 mm / 2.0, Group III : 2.Omm ${\times}$ 1.72 mm / 5.62, Group IV : 2.0 mm ${\times}$ 5.23 mm / 2.54. After treating with fifth-generation one-bottle adhesive - BC Plus$^{TM}$ (Vericom, AnYang, Korea), cavities were bulk flted with microhybrid composite resin - Denfill$^{TM}$ (Vericom). Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Specimens were thermocycled 500 times between 5$^{\circ}$C and 55$^{\circ}$C for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}$A) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. The results were as follows: 1. Small cavity volume showed lower microleakage score than large one, however, there was no statistically significant difference. 2. There was no relationship between cavity configuration and microleakage. Factors of cavity configuration and volume did not affect on microleakage of resin restorations with enamel margins only.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Regional cooperation of NOWPAP MERRAC against marine litter from sea-based activities in the Northwest Pacific region (북서태평양 지역의 해상기인 해양쓰레기 저감을 위한 NOWPAP 방제지역활동센터의 지역협력 활동현황 분석 및 향후 발전방향)

  • Noh, Hyon-Jeong;Oh, Jeong-Hwan;Kang, Seong-Gil;Kang, Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.3
    • /
    • pp.150-159
    • /
    • 2008
  • The marine litter generated as by-products of human activities and economic development enters to the sea through rivers or stream Indirectly, and through sea-based activities directly. It is commonly comprised of materials that degrade very slowly, such as various plastic products, polystyrene, glass, rubber, metal, wood, derelict fishing nets, wire, rope and so on. Such litter is found in the water column and on the seafloor as well as coastal areas In the Northwest Pacific region. It causes injury or death of human and other living organisms and also accident or damage of the vessel. It is not only a problem of country but also regional and/or global problem because it is transported by currents and winds from one country to another. In this regard, Northwest Pacific Action Plan (NOWPAP) Marine Litter Activity (MALITA) project had been carried out during 2006-2007 biennium and NOWPAP Regional Action Plan on Marine Litter (RAP MALI) has been also continuously implemented in the 2008-2009 biennium as next phase step of MALITA. MERRAC, one of four Regional Activity Centres (RACs) of NOWPAP, has developed monitoring guidelines, sectoral guidelines, and brochures related to sea-based marine litter and port reception facilities and services through MALITA project. Based upon these output, MERRAC will continuously implement relevant activities of RAP MALI in order to help to establish and improve a regional mechanism to deal with the sea-based marine litter problem. This paper aims to introduce MERRAC activities under MALITA and RAP MALI, and to suggest several recommendations to reduce marine litter in the NOWPAP region.

  • PDF

Fundamental Studies for the Breeding of Marine Algae 3. Effects of Plant Hormones on the Growth of Porphyra-fronds (해조의 육종을 위한 기초적 연구 3. 김 엽체에 미치는 식물호르몬의 생장효과)

  • KIM Joong-Rae;JO Young-Won;HAN Chang-Yeal;LEE Man-Sang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.2
    • /
    • pp.79-85
    • /
    • 1981
  • As one of the fundamental studies for the breeding of marine algae, the effects of several plant hormones (IAA, Gibberellin, 2.4-D, NAA, Kinetin) on the growth of Porphyra-fronds, P. tenera Kjell. form tamatsuensis Miura, were investigated from January 21 to February 21 1981. The fronds used for the experiment were dissected out at $25mm^2$ size, and cultured in modified Provasoli's ESP medium supplemented with various concentrations of each plant growth regulators. The culture was kept under constant water temperature of $5^{\circ}C$ in 14 hrs. photoperiod and illuminated with 2,400 lux by fluorescent light. Based on the results of first experiment, the culture of fronds for the secondary experiment was carried out at $5^{\circ}C\;and\;10^{\circ}C$ in medium containing various levels of Kinetin from April 6 to 24, and compared the growth of two groups at each concentrations with each other, The results obtained are summarized as follows : (1) The best growth efficiencies were observed at 5.0mg/1 of each plant hormones except Gibberellin. Among them, the highest growth-rate was $312.5\%\;(345.3\%\;in\;frond\;size)$ in contrast with control at 5.0mg/1 of Kinetin, and was followed by $257.5\%\;(236.1\%)$ in 2.4-D,$166.7\%(147.6\%)$ in IAA and $141.7\%\;(167.7\%)$ in NAA, but that in Gibberellin was $247.9\%(241.9\%)$ at 10.0mg/l. (2) Especially, the fronds cultured at 5.0mg/1 of Kinetin were deep black-brown in colour, and had vivid, healthy chloroplasts in their all cells. On the contrary, the fronds cultured in other media were discoloured to light black-brown or green-drown, and almost all cells were vacuolated or shrunk gradually into death.(3) There was an obvious difference between the best growth-rates of the fronds cultured at 5.0mg/l of Kinetin at $5^{\circ}C$ and those at $10^{\circ}C$. The former was $366.7\%$, the latter $318.8\%$ but the difference was little at lower concentrations. (4) Many abnormal cells grown up to $25.0-27.5\mu$ in diameter were found among the marginal cells of fronds which showed the best growth in Kinetin, and the fronds wire $41.0-42.0\mu$ in thickness which was thicker by $10.0\mu$ or so than the others. (5) In two fronds at 1.0mg/1 of Kinetin cell-divisions were observed, which might developed into antheridium, but it was doubtful whether due to the efficiency of Kinetin.

  • PDF

Effect of pore-water salinity on freezing rate in application of rapid artificial ground freezing to deep subsea tunnel: concentration of laboratory freezing chamber test (고수압 해저터널에 급속 인공동결공법 적용시 간극수의 염분 농도가 동결속도에 미치는 영향 평가: 실내 동결챔버시험 위주로)

  • Oh, Mintaek;Lee, Dongseop;Son, Young-Jin;Lee, In-Mo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.5
    • /
    • pp.401-412
    • /
    • 2016
  • It is extremely difficult to apply conventional grouting methods to subsea tunnelling construction in the high water pressure condition. In such a condition, the rapid artificial freezing method can be an alternative to grouting to form a watertight zone around freezing pipes. For a proper design of the artificial freezing method, the influence of salinity on the freezing process has to be considered. However, there are few domestic tunnel construction that adopted the artificial freezing method, and influential factors on the freezing of the soil are not clearly identified. In this paper, a series of laboratory experiments were performed to identify the physical characteristics of frozen soil. Thermal conductivity of the frozen and unfrozen soil samples was measured through the thermal sensor adopting transient hot-wire method. Moreover, a lab-scale freezing chamber was devised to simulate freezing process of silica sand with consideration of the salinity of pore-water. The temperature in the silica sand sample was measured during the freezing process to evaluate the effect of pore-water salinity on the frozen rate that is one of the key parameters in designing the artificial freezing method in subsea tunnelling. In case of unfrozen soil, the soil samples saturated with fresh water (salinity of 0%) and brine water (salinity of 3.5%) showed a similar value of thermal conductivity. However, the frozen soil sample saturated with brine water led to the thermal conductivity notably higher than that of fresh water, which corresponds to the fact that the freezing rate of brine water was greater than that of fresh water in the freezing chamber test.

Kinetic Studies of Lactic Acid Fermentation (Part 3) Effect of Phenol Derivatives on Fermentation (유산균발효에 관한 동력학적 연구 (제3보) 발효에 미치는 Phenol 유도체의 영향)

  • LEE Keun-Tai;YANG Hyeun-Suk
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.212-216
    • /
    • 1981
  • The growth of Lactobacillus bulgaricus treated with vanillin, ortho-vanillin and guaiaco1 was studied on synthetic medium in mechanically agitated chemostat culture, The exponential-phase growth rate exhibited a maximum at the cells treated with 50 ppm vanillin. That stimulation, however, appears to be an effect on growth rate rather than total cell growth. And the others were inhibited by the chemicals. Much greater inhibition in growth of the cells treated with 100 ppm of each chemical than oars treated with 50 ppm was observed after 25 hour fomentation. For aerobic microbes, the alcohol dehydrogenase reaction is enhanced for the reproduction of NAD, which consequently cause to stimulate fermentation. For micro-aerophilic microbes , however, the same effect was not observed at the present study at least in the case of cell concentration. However except f or one treated with 50 ppm vanillin the same effect was observed in the case of growth is to. From the result using the glucose as a substrate, it was found that the cell concentrations measured in terms of ultimate optical density (UOB/ml), were 0.96 and 0.92, when treated with 50 and 100 ppm vanillin; 0.40 and 0.45 when treated with ortho-vanillin 50 and 100 ppm: 0.49 and 0.47, when treated with guaiacol 50 and 100 ppm. The specific growth rates were 0.44, 0.15, 0.25, 0.29, 0.37, and 0.34; the specific production rates wire 0.33, 0.15, 0.16, 0.22, 0.28, and 0.26 and the glucose concentrations (g/1) after 25 hour fermentation were 23.5, 32.8, 31.5, 29.5, 28.0 and 28.8, these all in the same sequences as the first.

  • PDF