• Title/Summary/Keyword: One point detection

Search Result 374, Processing Time 0.023 seconds

Vibration Measurements and Verification Based on Image Processing Using Optical Flow (옵티컬 플로우를 이용한 영상처리 기반 진동 계측 및 검증)

  • Jun-Byung Baek;Tae-Hee Lee;Soo-Yeon Lim;Bong-Yeol Choi;Doo-Hyun Choi
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.384-390
    • /
    • 2024
  • Conventional vibration-measurement methods used for vibration testing typically employ accelerometers, which offer the significant advantage of accurately measuring vibrations at specific positions. However, they can only measure one point at a time as simultaneously measurements of multiple points can be economically disadvantageous. This study aims to overcome these limitations by analyzing the vibration outputs of accelerometers attached to a product and those obtained through image processing. The analysis involved assessing the measurement uncertainties and verifying the low-frequency vibration testing according to KS standards. The results validated and confirmed the reliability of the proposed camera-based image-processing vibration-measurement method, which exhibited a notable vibration-detection performance and measurement errors within 5% compared to accelerometers for low-frequency vibrations. This method has the potential for application across various vibration-response and durability evaluations. Future research should focus on expanding it to high-frequency vibration testing using high-speed cameras and further enhancing image-based vibration-analysis techniques.

Seroepidemiology of Hepatitis B Virus Infection in Healthy Korean Adults in Seoul (정상 성인에 있어서의 B형 간염 바이러스 감염에 관한 혈청역학적 연구)

  • Yoo, Keun-Young;Park, Byung-Joo;Ahn, Yoon-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.89-98
    • /
    • 1988
  • While there have been not a few reports on the seroepidemiological characteristics of hepatitis B virus (HBV) infection in Korea, most of them, however, have had several limitations; operational definition of HBV infection, validity of detection methods of HBV serologic markers, size of the study population, and confirmation of the vaccination history against HBV, etc. In order to avoid such limitations, authors randomly selected 1,495 healthy adults among the 217,511 insured (target population) of Korean Medical Insurance Corporation, living in seoul, and tested HBV serologic markers by RIA method and conducted direct interview to them. Although HBV serologic markers (HBsAg, anti-HBs and anti-HBc) of all the subjects were tested, 392(26.2%) of interview failure cases and 361 vaccinee were excluded from the actual population. Finally, the serologic markers tested of 742 nonvaccinee (study population) only were analysed for the seroepidemiologic observation of the natural infection of HBV. The seroepidemiological characteristics of HBV infection in Korea were as follows ; 1. Point prevalence of HBs antigenemia was 11.7(9.1{\sim}14.3)% in male, which was slightly higher than that of female, 9.5($3.7{\sim}15.3$)%. This level was one of the highest among those of Asian-Pacific countries. Decreasing tendency of HBsAg prevalence alter the age of 50 was observed, which seems to be due to selective attrition of HBV chronic carriers among the healthy adults and/or to the limited-lasting duration of the HBs antigenemia, in part. 2. Point prevalence of anti-HBc(78.8% in male,50.9% in female) was higher than that of anti-HBs(65.2% in male,46.6% in female), respectively. And both of them were higher in male than in female. Increasing tendency of the prevalence of both antibodies was observed by age, which seems to be largely due to recurrent infection in adults and to some cumulative effect, in part, of their relatively longer-lasting duration. 3. The level of HBV infection defined by positive for at least one of the 3 serologic markers of HBV by RIA method was 84.7($81.8{\sim}87.6$)% in male and 61.2($51.9{\sim}70.5$)% in female, which was also one of the highest among those of Asian-Pacific countries. The proportion of susceptible population to HBV infection among healthy adults was 15.3% in male and 38.8% in female. 4. The relative frequency of current or past infection and chronic carrier among HBV infected person was estimated. The currently or past infected was estimated 75.7% in male and 71.8% in female, and chronic carrier state, 13.8% in male and 14.1% in female. The analysis of the geometric mean of the antibody titer in anti-HBs positive sera indicated also to be compatible with the above findings, suggesting that active, even though inapparent, infection of HBV occur so frequently among healthy adults in Korea.

  • PDF

Seismic interval velocity analysis on prestack depth domain for detecting the bottom simulating reflector of gas-hydrate (가스 하이드레이트 부존층의 하부 경계면을 규명하기 위한 심도영역 탄성파 구간속도 분석)

  • Ko Seung-Won;Chung Bu-Heung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.638-642
    • /
    • 2005
  • For gas hydrate exploration, long offset multichannel seismic data acquired using by the 4km streamer length in Ulleung basin of the East Sea. The dataset was processed to define the BSRs (Bottom Simulating Reflectors) and to estimate the amount of gas hydrates. Confirmation of the presence of Bottom Simulating reflectors (BSR) and investigation of its physical properties from seismic section are important for gas hydrate detection. Specially, faster interval velocity overlying slower interval velocity indicates the likely presences of gas hydrate above BSR and free gas underneath BSR. In consequence, estimation of correct interval velocities and analysis of their spatial variations are critical processes for gas hydrate detection using seismic reflection data. Using Dix's equation, Root Mean Square (RMS) velocities can be converted into interval velocities. However, it is not a proper way to investigate interval velocities above and below BSR considering the fact that RMS velocities have poor resolution and correctness and the assumption that interval velocities increase along the depth. Therefore, we incorporated Migration Velocity Analysis (MVA) software produced by Landmark CO. to estimate correct interval velocities in detail. MVA is a process to yield velocities of sediments between layers using Common Mid Point (CMP) gathered seismic data. The CMP gathered data for MVA should be produced after basic processing steps to enhance the signal to noise ratio of the first reflections. Prestack depth migrated section is produced using interval velocities and interval velocities are key parameters governing qualities of prestack depth migration section. Correctness of interval velocities can be examined by the presence of Residual Move Out (RMO) on CMP gathered data. If there is no RMO, peaks of primary reflection events are flat in horizontal direction for all offsets of Common Reflection Point (CRP) gathers and it proves that prestack depth migration is done with correct velocity field. Used method in this study, Tomographic inversion needs two initial input data. One is the dataset obtained from the results of preprocessing by removing multiples and noise and stacked partially. The other is the depth domain velocity model build by smoothing and editing the interval velocity converted from RMS velocity. After the three times iteration of tomography inversion, Optimum interval velocity field can be fixed. The conclusion of this study as follow, the final Interval velocity around the BSR decreased to 1400 m/s from 2500 m/s abruptly. BSR is showed about 200m depth under the seabottom

  • PDF

Effect of missing values in detecting differentially expressed genes in a cDNA microarray experiment

  • Kim, Byung-Soo;Rha, Sun-Young
    • Bioinformatics and Biosystems
    • /
    • v.1 no.1
    • /
    • pp.67-72
    • /
    • 2006
  • The aim of this paper is to discuss the effect of missing values in detecting differentially expressed genes in a cDNA microarray experiment in the context of a one sample problem. We conducted a cDNA micro array experiment to detect differentially expressed genes for the metastasis of colorectal cancer based on twenty patients who underwent liver resection due to liver metastasis from colorectal cancer. Total RNAs from metastatic liver tumor and adjacent normal liver tissue from a single patient were labeled with cy5 and cy3, respectively, and competitively hybridized to a cDNA microarray with 7775 human genes. We used $M=log_2(R/G)$ for the signal evaluation, where Rand G denoted the fluorescent intensities of Cy5 and Cy3 dyes, respectively. The statistical problem comprises a one sample test of testing E(M)=0 for each gene and involves multiple tests. The twenty cDNA microarray data would comprise a matrix of dimension 7775 by 20, if there were no missing values. However, missing values occur for various reasons. For each gene, the no missing proportion (NMP) was defined to be the proportion of non-missing values out of twenty. In detecting differentially expressed (DE) genes, we used the genes whose NMP is greater than or equal to 0.4 and then sequentially increased NMP by 0.1 for investigating its effect on the detection of DE genes. For each fixed NMP, we imputed the missing values with K-nearest neighbor method (K=10) and applied the nonparametric t-test of Dudoit et al. (2002), SAM by Tusher et al. (2001) and empirical Bayes procedure by $L\ddot{o}nnstedt$ and Speed (2002) to find out the effect of missing values in the final outcome. These three procedures yielded substantially agreeable result in detecting DE genes. Of these three procedures we used SAM for exploring the acceptable NMP level. The result showed that the optimum no missing proportion (NMP) found in this data set turned out to be 80%. It is more desirable to find the optimum level of NMP for each data set by applying the method described in this note, when the plot of (NMP, Number of overlapping genes) shows a turning point.

  • PDF

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Effect of Education on Knowledge, Attitude and Behavioral Intention in Family Relative with Colorectal Cancer Patients Based on Theory of Planned Behavior

  • Baghianimoghadam, Mohammad Hosein;Ardakani, Mojtaba Fattahi;Akhoundi, Mohsen;Mortazavizadeh, Mohammad Reza;Fallahzadeh, Mohammad Hosein;Baghianimoghadam, Behnam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.5995-5998
    • /
    • 2012
  • Background: Colorectal cancer is one of most common cancers in women and men and one of the major causes of death due to neoplasia. Colonoscopy is considered as the most accurate diagnostic procedure to detect colorectal cancer at the earlier stages. Objectives: The current study aimed to evaluate the effects of an education program using the Theory of Planned Behavior on promoting behavioral intention among first degree relatives of colorectal cancer patients. Materials and Methods: A quasi-experimental study conducted to evaluate the effectiveness of an educational program to promote attitudinal factors associated with early detection of colorectal cancer in 99 first degree relatives of colorectal cancer patients aged more than 20 years in Yazd city, Iran. A researcher made questionnaire forwhich validity and reliability were confirmed by expert point of view and pilot testing was employed for data collection. Questionnaires were filled in before and after educational intervention. The registered data were transferred to SPSS 19 and analyzed by paired T-test, Man-Whitney and Wilcaxon. Results: Mean scores of knowledge, attitude, perceived behavioral control and intention regarding colorectal cancer increased after education significantly (P<0.05). Conclusions: Application of the Theory of Planned Behavior has positive influence on promoting intention behavior. It is therefore recommended to apply educational programs to promote behavioral intention.

"Dust, Ice, and Gas In Time" (DIGIT) Herschel Observations of GSS30-IRS1 in Ophiuchus

  • Je, Hyerin;Lee, Jeong-Eun;Green, Joel D.;Evans, Neal J. II
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.63.2-63.2
    • /
    • 2014
  • As a part of the "Dust, Ice, and Gas In Time" (DIGIT) key program on Herschel, we observed GSS30-IRS1, a Class I protostar located in Ophiuchus (d =125 pc), with Herschel/Photodetector Array Camera and Spectrometer (PACS). More than 70 lines were detected within a wavelength range from 50 ${\mu}m$ to 200 ${\mu}m$: CO lines from J = 14-13 to 41-40, several $H_2O$ lines of Eup = 100 K to 1500 K, 16 transitions of OH rotational lines, and two atomic [O I] lines at 63 and 145 ${\mu}m$. The [C II] line, known as a tracer of externally heated gas by the interstellar radiation field, is also detected at 158 ${\mu}m$. All lines, except [O I] and [C II], are detected only at the central spaxel of $9^{\prime\prime}.4{\times}9^{\prime\prime}.4$. The [O I] emission is extended along a NE-SW orientation, which is consistent with the known outflow direction, while the [C II] line is detected over all spaxels. One possible explanation of the detection of the [C II] line and no correlation of its spatial distribution with any other molecular emission is the existence of the enhanced ISRF nearby GSS30-IRS1. One interesting feature of GSS30-IRS1 is that the continuum emission is extended beyond the point-spread function (PSF), unlike the molecular line emission, indicative of significant external heating. The best-fit continuum model of GSS30-IRS1 with the physical structure including flared disk, envelope, and outflow shows that the internal luminosity is 11 $L_{\odot}$, and the region is also externally heated by a radiation field enhanced by a factor of 25 compared to the local standard interstellar field.

  • PDF

NEW PHOTOMETRIC PIPELINE TO EXPLORE TEMPORAL AND SPATIAL VARIABILITY WITH KMTNET DEEP-SOUTH OBSERVATIONS

  • Chang, Seo-Won;Byun, Yong-Ik;Shin, Min-Su;Yi, Hahn;Kim, Myung-Jin;Moon, Hong-Kyu;Choi, Young-Jun;Cha, Sang-Mok;Lee, Yongseok
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.5
    • /
    • pp.129-142
    • /
    • 2018
  • The DEEP-South (the Deep Ecliptic Patrol of the Southern Sky) photometric census of small Solar System bodies produces massive time-series data of variable, transient or moving objects as a by-product. To fully investigate unexplored variable phenomena, we present an application of multi-aperture photometry and FastBit indexing techniques for faster access to a portion of the DEEP-South year-one data. Our new pipeline is designed to perform automated point source detection, robust high-precision photometry and calibration of non-crowded fields which have overlap with previously surveyed areas. In this paper, we show some examples of catalog-based variability searches to find new variable stars and to recover targeted asteroids. We discover 21 new periodic variables with period ranging between 0.1 and 31 days, including four eclipsing binary systems (detached, over-contact, and ellipsoidal variables), one white dwarf/M dwarf pair candidate, and rotating variable stars. We also recover astrometry (< ${\pm}1-2$ arcsec level accuracy) and photometry of two targeted near-earth asteroids, 2006 DZ169 and 1996 SK, along with the small- (~0.12 mag) and relatively large-amplitude (~0.5 mag) variations of their dominant rotational signals in R-band.

VILODE : A Real-Time Visual Loop Closure Detector Using Key Frames and Bag of Words (VILODE : 키 프레임 영상과 시각 단어들을 이용한 실시간 시각 루프 결합 탐지기)

  • Kim, Hyesuk;Kim, Incheol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.5
    • /
    • pp.225-230
    • /
    • 2015
  • In this paper, we propose an effective real-time visual loop closure detector, VILODE, which makes use of key frames and bag of visual words (BoW) based on SURF feature points. In order to determine whether the camera has re-visited one of the previously visited places, a loop closure detector has to compare an incoming new image with all previous images collected at every visited place. As the camera passes through new places or locations, the amount of images to be compared continues growing. For this reason, it is difficult for a visual loop closure detector to meet both real-time constraint and high detection accuracy. To address the problem, the proposed system adopts an effective key frame selection strategy which selects and compares only distinct meaningful ones from continuously incoming images during navigation, and so it can reduce greatly image comparisons for loop detection. Moreover, in order to improve detection accuracy and efficiency, the system represents each key frame image as a bag of visual words, and maintains indexes for them using DBoW database system. The experiments with TUM benchmark datasets demonstrates high performance of the proposed visual loop closure detector.

A Brazing Defect Detection Using an Ultrasonic Infrared Imaging Inspection (초음파 열 영상 검사를 이용한 브레이징 접합 결함 검출)

  • Cho, Jai-Wan;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.426-431
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material in real time. In this paper a realtime detection of the brazing defect of thin Inconel plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (23 kHz) ultrasonic transducer was used to infuse the welded Inconel plates with a short pulse of sound for 280 ms. The ultrasonic source has a maximum power of 2 kW. The surface temperature of the area under inspection is imaged by an infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the bound between the two faces of the Inconel plates near the defective brazing point and heated up highly, are observed. And the weak thermal signal is observed at the defect position of brazed plate also. Using the image processing technology such as background subtraction average and image enhancement using histogram equalization, the position of defective brazing regions in the thin Inconel plates can be located certainly.