• 제목/요약/키워드: Ondol Floor

검색결과 143건 처리시간 0.019초

온돌난방공간(溫突暖房空間)의 내표면(內表面) 대류열전달특성(對流熱傳達特性)에 관(關)한 연구(硏究) (Convection Heat-Transfer Characteristics of Ondol-Heated Room)

  • 손장열;안병욱
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.376-385
    • /
    • 1991
  • The purpose of this paper is to propose basic data on convection heat-transfer coefficients in Ondol-heated room. Surface temperatures and several temperatures around each inside surface of wall, floor and ceiling composed of heating room are measured vertically in Ondol-heated model rooms, and the vertical temperature profiles could be expressed by nonlinear equation models. Also, the convection heat transfer phenomena are analysed from the nonlinear equation models. In the results, the convection heat-transfer coefficients of Ondol heated space are suggested by the term of temperature difference between each wall surface and room air temperature and by the relationship between Nusselt number and Rayleigh number of dimensionless numbers.

  • PDF

강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구 (A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe)

  • 김창희;김종수;우재호;공상운
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

잠열 축열-바이오 세라믹 온돌의 난방 특성 - 온돌의 역사적 고찰 및 실험적 분석을 중심으로 - (Floor Heating Characteristics of Latent Heat Storage-Bioceramic Ondal - Focused on Historical research and Expermental Analysis -)

  • 송현갑;유영선
    • 태양에너지
    • /
    • 제15권1호
    • /
    • pp.13-28
    • /
    • 1995
  • 온돌의 효시인 화덕은 바닥에 자갈을 깔고 그 위에 진흙을 덮었으며, 주위에 큰돌을 놓아 불을 피워 돌과 흙에 열을 저장하여 이용하였으며, 이는 열저장 측면에서 주시할만한 난방법이었다. 현재의 한국식 주거용 난방시설은 연탄, 석유 및 가스 보일러를 이용한 온수순환온돌로서 전통온돌에서 사용한 돌과 흙같은 축열매체가 사용되고 있지 않다. 축열매체를 사용하고 있지 않기 때문에 온돌바닥면과 난방공간과의 온도차가 심하게 되어 쾌적도가 떨어지므로 난방열을 지속적으로 공급해야 하는 어려움이 있다. 이와 같은 현재의 난방법을 개선기 위하여, 본 연구에서는 잠열축열재와 바이오세라믹으로 구성된 온돌을 개발하였고, 그 난방특성을 실험적으로 분석하였다.

  • PDF

중국 길림성(吉林省)에 거주하는 조선족(朝鮮族)의 주거 및 주생활 - 재한(在韓) 조선족 이주 노동자의 주거 계획을 위한 기초 연구 - (An Analysis of Housing and Domestic Living of ChoSun-Tribe in China - Focusing on Housing Plans for Immigrant Workers in Korea -)

  • 이영심;최정신
    • 대한가정학회지
    • /
    • 제45권7호
    • /
    • pp.1-15
    • /
    • 2007
  • The purpose of this study is getting information for making a plan of immigrant workers in Korea. As a first step to suggest plans for immigrant workers who have multi-cultural background, this study investigated to the domestic living of Koreans(ChoSun-Tribe) of Gillim province in China. For this, usage of domestic space questionnaire were used. Results of the research were as follows. 1. The most popular LDK type was the one which kitchen was separated from living room and dining room. Most of them thought that kitchen and living room have to be separated. 2. There was no plan for laundry room specially and most houses have a washing machine in the bathroom. Most houses didn't install a bathtub in the bathroom and they didn't think that it was indispensable. 3. It was estimated that they used a living room as a multi-purpose room for the family but used a master bedroom for its own purpose. 4. They used a table and chair for meals normally but they took meals sitting on the floor with a large family or guest. 5.All of them took off the shoes inside of the house for hygienic reason. There was no plan for the space to take on-off shoes in most houses and they just put the mat on the floor for it. 6. Modified Ondol system which use water pipe under the floor was popular in apartment while most detached houses had traditional Ondol system. The satisfaction about Ondol system was very high compared to other ones and also Ondol system was the most desirable one for ChoSun-Tribe.

독락당과 계정의 원형과 변화과정 연구 (A Study on the Original Form and Change of Dokrak-dang and Gye-jeong)

  • 김도경
    • 건축역사연구
    • /
    • 제23권5호
    • /
    • pp.23-36
    • /
    • 2014
  • Source criticism is very important on the research of architectural history as well as general history. In this point this research studied on the original form and change of Dokrak-dang that is very important building in architectural history of Korea. The result is as in the following. Dokrak-dang that Whoijae built at first was three by two kans size that had daecheong of four kans and ondol-bang of two kans. Gye-jeong that Whoijae built was three kans size that had daecheong of two kans and ondol-bang of one kan. After Whoijae died, Dokrak-dang's ondol-bang was changed to maru between 1555 and 1556 and ondol-bang in west side and stack room was added in 1630. Gye-jeong was changed to ㄱ-shaped floor plan that was added up two kans from three kan's 'ㅡ'-shaped one.

수치해석을 통한 구들의 열 흐름 특성 연구 (Heat Flow Characteristics of Traditional Ondol (Gudle) by Numerical Analysis)

  • 리신호;리광훈
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.17-22
    • /
    • 2007
  • The heat flow characteristics of the Gudle (traditional Ondol) used a lot at farm houses have been performed with variations of Bunengki (Fireridge) by numerical analysis and field experiment. The Doedon-Gorae (Return-Firetunnel) Gudle is analyzed among the structure of Gudle. The distribution of heat flow in Gorse (Firetunnel) and the temperature distribution in floor of 3 Buneomgi (Fire ridge) was more uniform than that of 1 Buneomgi. The heat efficiency of 3 Buneomgi was higher than that of 1 Bunengki. That is, the 3 Bunengk is more efficient and more uniform temperature.

온돌을 이용한 복사냉방의 가능성에 관한 연구 (A study on the applicability of radiant cooling using Ondol)

  • 구소영;김용이;석호태;이현우;김광우
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.200-208
    • /
    • 2000
  • The use of air-conditioning systems for cooling in residential buildings has negative effects on the environment and causes the problem in peak electric power demand in summer. The objective of this study is to demonstrate the potential of radiant cooling systems using ondol as an alternative cooling system in our residential buildings. Computer simulation has been performed for the floor radiant cooling system performance. The results of this study show that. 1) This system can control the temperature of Ondol room within comfort limits. 2) This system can be operated with a little risk of condensation but the control of latent heat will make this system more potential.

  • PDF

PCM을 이용한 온돌패널의 실험 및 특성연구 (Experiment and Property Study of Ondol Panel Based on Phase Change Material)

  • 윤두한;최봉수;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.122-125
    • /
    • 2006
  • This paper deals with the Ondol, Korean under-floor heating system using latent heat storage materials. It has been recognized that the heating system using the latent heat storage materials are economically efficient and comfortable. For the comparison and analysis to the data of the existing experiment, a repetitive experiment makes sure the ability of Ondol panel.

  • PDF

부분적으로 가열되는 평판열교환기의 열전달해석 (The Constriction Resistance in Partially Heated Channel Plate Heat Exchangers)

  • 강신형;배순훈
    • 대한설비공학회지:설비저널
    • /
    • 제4권2호
    • /
    • pp.115-118
    • /
    • 1975
  • The constriction thermal resistance due to the floor supports in the Ondol floor heating system was investigated. The resistance has significant influence on the uniformity of floor surface temperature and heat flux through the floor. The heat flux decreased as much as $30\%$ for the geometry of the same channel and support areas.

  • PDF

발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구 (The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation)

  • 윤창연;정정호;김명준
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.