• Title/Summary/Keyword: On-spot test

Search Result 487, Processing Time 0.028 seconds

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

Spot Test for Amins Acids with Alloxan (Alloxan 에 의한 Amino Acids 의 Spot Test)

  • Kim, Tae-Bong;Hahn, Bo-Sup
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.2
    • /
    • pp.85-87
    • /
    • 1964
  • In order to stabilze alloxan as a reagent for detection of amino acids by spot test, sugars and other reductants were added to the aqueous alloxan solution. It was found that lactose was the best for the purpose. The alloxan reagent containing lactose did not give color change on blank test and was very stable that there was no color change even it was allowed to stand in room temperature for several months. The color reaction with amino acids and some amines was not affected by lactose. This spot test for amino acids is in sensitivity as comparable to that of the previously reported methods and gave color reaction with proline and hydroxyproline to 1${\gamma}$ and 5${\gamma}$ respectively.

  • PDF

A Study on the Bending Strength of a Built-up Beam Fabricated by the $CO_2$ Arc Spot Welding Method ($CO_2$아크 스폿 용접법에 의한 조립보의 굽힘강도에 관한 연구)

  • 한명수;한종만;이준열
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.143-153
    • /
    • 1997
  • In this study, bending test was performed on the real-scale, built-up beam test model fabricated by the $CO_2$ arc spot welding to evaluate the applicability of the welding method to the production of the stiffened plate in car-carrying ship. The built-up beam models which were fixed at both ends in longitudinal direction or simply supported to the rigid foundation, depending on the restraint condition of the corresponding car decks considered, were subjected to simulated design vehicle loads or concentrated point loads. During the test, the central deflection and the longitudinal bending stresses were measured from several points on the longitudinal flange face to predict the section properties of the built-up beams. The longitudinal bending stress on each spot weld were also measured to calculate the average horizontal shear force subjected to spot welds. Test results revealed that the shear strength of spot welds with their current weld nugget size and welding pitch was adequate enough to withstand the horizontal shear forces under the design vehicle loads. Although the built-up beam fabricated by the arc spot welding was a discontinuous beam, its mechanical behavior was well explained by the continuous beam theory using the effective breadth of plate. Based on test results, the criterion for the size of spot weld of which the average shear stress might meet the allowable stress requirement of AWS Code could be established.

  • PDF

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

Effect of Paint Baking on the Strength and Failure of Spot Welds for 780 TRIP Steels (780 MPa급 TRIP강의 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향)

  • Son, Jong-Woo;Nam, Dae-Geun;Kim, Dong-Cheol;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.28 no.2
    • /
    • pp.66-73
    • /
    • 2010
  • Conventional fracture test of resistance spot weld had been performed without consideration of paint baking process in automobile manufacturing line. This study was aim to investigate the effect of paint baking on fracture mode and load carrying capacity in fracture test for resistance spot welded 780TRIP steels. With paint baking cycle after resistance spot welds, peel tests and microhardness were conducted on the as-welded and baked samples. Resistance spot welds in AHSS (Advanced High Strength Steels) are prone to display partial interfacial fractures during fracture test or vehicle crash. Baking cycle increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial to full button fracture for the L-type peel tests. Specially, the differences in fracture appearance are apparent when the nugget size of spot welds is small enough to produce the partial interfacial fracture. The comparison of macrohardness and microstructure between as-welded and baked samples showed that there are no large difference in change the fracture mode. However, the results of the instrumented indentation test suggested that fusion zone and HAZ of baked sample have less tensile and yield strength and proves that the tempering effects are applied and enhanced the resistance to fracture on welds with application of baking cycle.

A Study on Effects of Welding Clearance on Spot Weldability (점용접 간극이 용접성에 미치는 영향에 관한 연구)

  • 임재규;양승현;국중하
    • Journal of Welding and Joining
    • /
    • v.20 no.1
    • /
    • pp.55-61
    • /
    • 2002
  • The automobile is made up of about twenty thousand parts. Some parts are formed by pressing and combined by spot welding. Among them, steel palate of fuel tank is formed in the metal mold and bending parts are jointed by spot and seam welding. To find weldability conditions of spot welding, clearance between two welding steel plates was made and after spot welding, weldability is evaluated by means of tensile shear load, nugget size and shape. Specimen used in this study was a mild steel of 1.2mm thickness and electrode was Cu-Cr alloy of 6mm diameter. When spot welding started, the clearance of two steel plates was changed 0mm, 3mm and 5mm step by step. The fractured surface of specimen after this test was observed by Optical Microscope to measure microstructure and nugget shape. When clearance of two specimen was 3mm and 5mm, strength and nugget size was decreased and nugget shape was not clear.

The microdetection of alkaloids with amberlite IRC-50 (Amberlite IRC-50에 의한 alkaloid의 미량검출법)

  • 김근영;이윤중;손윤자
    • YAKHAK HOEJI
    • /
    • v.11 no.1_2
    • /
    • pp.4-6
    • /
    • 1967
  • Cation exchange resin particles amberlite IRC-50 were used as a medium for a identific test of alkaloids with dragendorff reagent. The procedures were as follows; A few particles of amberlite IRC-50 were added to the small portion of sample solutions on a spot plate or in a test tube. After 20 minutes-an hour, a drop of dragendorff reagent were added to particles of resin that were adsorbed. When alkaloid was present, the original color of the resin particles changed instantly to red or reddish orange depending on the amount and kind of alkaloid, while in the absence of alkaloid the original color of the resin particles changed light yellow. These methods were more sensitive than the ordinary spot test or paper spot test for alkaloid. The limits of identifications of nine alkaloids were tested by these methods and compared with the paper spot test method.

  • PDF

A Study on Price Discovery Function of Japan's Frozen Shrimp Future Market (일본 냉동새우 선물시장의 가격발견기능에 관한 연구)

  • Nam Soo-Hyun
    • The Journal of Fisheries Business Administration
    • /
    • v.37 no.1 s.70
    • /
    • pp.95-110
    • /
    • 2006
  • Japan's frozen shrimp future market is the only fisheries future commodity market in the world. This empirical study examines the lead and lag relationship between Japan frozen shrimp spot and future markets using the daily prices from August 1, 2002 to December 31, 2005. Frozen shrimp future contract is listed on Japan Kansai Commodities Exchange. Japan imports approximately 250,000 tons of frozen shrimp annually, of which just under 70,000 tons, nearly 30%, are black tiger shrimp. Approximately 90% of black tiger shrimp are caught in Indonesia, India, Thailand and Vietnam, and the two largest consumers of these shrimp are Japan and the U.S.A. Kansai Commodities Exchange adopts the India black tiger shrimp as standard future commodity. We use unit root test, Johansen cointegration test, Granger causality test, Vector autoregressive analysis and Impulse response analysis. However, considering the long - term relationships between the level variables of frozen shrimp spot and futures, we introduced Vector Error Correction Model. We find that the price change of frozen shrimp futures with next 1, 2, 3, 4, 5 month maturity have a strong predictive power to the change of frozen shrimp spot and the change of frozen shrimp spot also have a predictive power to the change of frozen shrimp with next 1, 2, 3 month maturity. But, the explanatory power of the frozen shrimp futures is relatively greater than that of frozen shrimp spot.

  • PDF

A Study on the Fatigue Behavior of Resistance Spot Welded Part of 5182 Aluminum Aloy Sheet (5182 Al합금판의 전기저항 점용접부 피로거동에 관한 연구)

  • 신현일;박용석;강성수
    • Journal of Welding and Joining
    • /
    • v.16 no.2
    • /
    • pp.84-92
    • /
    • 1998
  • On this study, the variations of hardness and microstructure were observed at he spot-welded part of 5182 alminum alloy sheets with thickness of 1.2 mm. The hardness of spot-welded part of aluminum alloy indicated the lowest value at nugget center. Also, the position where fatigue crack exists was investigated by surveying microstructure of the spot-welded sections. Mean load-deformation diagrams were obtained from static tensile test. Fracture was occurred completely within 5 mm after transforming elastic into plastic area. Fatigue test was stopped when the specimens of fatigue test had the final displacement of 0.2mm and measured fatigue bending angle and crack length. This study utilized them, investigated the relations between fatigue bending angle and fatigue crack length and made a estimation of the fatigue fracture life of resistance spot welded part of 5182 aluminum alloy sheet. The relative equation o fatigue crack length and fatigue failure life can be represented by {TEX}$L_{C}${/TEX}=α{TEX}$N_{f}^ {β}${/TEX}.

  • PDF

The Study on Inverter DC Resistance Spot Welding Character & Mechanical Property of DP60 Steels (DP60강의 인버터 DC 저항 용접의 용접 특성 및 기계적 성질에 관한 연구)

  • Kim, In-Ju
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.604-606
    • /
    • 2011
  • Purpose This study analyzes resistance spot weldability of DP60 steels. Methodology To compare the resistance spot weldability of DP60 steels, tensile strength test and macro-section test were conducted for the resistance spot welds. Acceptable welding conditions were determined as a function of the resistance spot welding process parameters such as electrode force, welding time, and welding current. The lower limit of the welding lobe was the minimum shear tension strength for 590MPa-grade steel while the upper limit was determined whether or not expulsion was detected. Findings Welding force is 200kgf more appropriate in terms of 300kgf the larger the width of the welding zone. Acceptable welding current condition and welding lobe were changed depending on welding force. Research limitations This study is forced on inverter DC resistance spot weldability of 590Mpa-grade steels for automotive application. Practical implications This study confirms the weldability of DP60 steel by comparing resistance spot weldability depending on welding force. Originality This study analysed resistance spot weldability depending on welding force. wedability of DP60 steel were determined by welding lobes.

  • PDF