• Title/Summary/Keyword: On-site measurement

Search Result 1,100, Processing Time 0.032 seconds

A Study on Effective Web Site Implementation using Reliability Measurement (신뢰도 측정을 통한 효과적인 웹 사이트 구축 방안에 관한 연구)

  • Kwon, Young-Gik;Cui, Jun;Kwon, Dong-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.802-812
    • /
    • 2011
  • In this paper, we derived 7 reliability measurement factors for effective web site construction through literature research and empirically measured reliability of the web site using "Xenu" and "Yslow" which are reliability measurement tools. We selected and tested total 12 domestic and foreign web sites. As a result of measuring those 12 web sites, the reliability level was varied in a number of aspects according to 7 measurement factors, and we suggested alternatives based on those 7 factors in order to build the effective web site.

Application of In Situ Measurement for Site Remediation and Final Status Survey of Decommissioning KRR Site

  • Hong, Sang Bum;Nam, Jong Soo;Choi, Yong Suk;Seo, Bum Kyoung;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.173-178
    • /
    • 2016
  • Background: In situ gamma spectrometry has been used to measure environmental radiation, assumptions are usually made about the depth distribution of the radionuclides of interest in the soil. The main limitation of in situ gamma spectrometry lies in determining the depth distribution of radionuclides. The objective of this study is to develop a method for subsurface characterization by in situ measurement. Materials and Methods: The peak to valley method based on the ratio of counting rate between the photoelectric peak and Compton region was applied to identify the depth distribution. The peak to valley method could be applied to establish the relation between the spectrally derived coefficients (Q) with relaxation mass per unit area (${\beta}$) for various depth distribution in soil. The in situ measurement results were verified by MCNP simulation and calculated correlation equation. In order to compare the depth distributions and contamination levels in decommissioning KRR site, in situ measurement and sampling results were compared. Results and Discussion: The in situ measurement results and MCNP simulation results show a good correlation for laboratory measurement. The simulation relationship between Q and source burial for the source layers have exponential relationship for a variety depth distributions. We applied the peak to valley method to contaminated decommissioning KRR site to determine a depth distribution and initial activity without sampling. The observed results has a good correlation, relative error between in situ measurement with sampling result is around 7% for depth distribution and 4% for initial activity. Conclusion: In this study, the vertical activity distribution and initial activity of $^{137}Cs$ could be identifying directly through in situ measurement. Therefore, the peak to valley method demonstrated good potential for assessment of the residual radioactivity for site remediation in decommissioning and contaminated site.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

The Case Study of the Effective Management of the Site Using Measurement Result During the Excavation Construction (굴착공사 중 계측결과 활용을 통한 효과적인 현장관리 사례 분석)

  • NamGung, Han;Jung, Kyoung-Sik;Koh, Hyung-Seon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.428-444
    • /
    • 2010
  • After underground excavation being introduced in dometic, many technologies have been storing up. One of them, measurement, has been recognized as an important item under excavation construction. But, unlike a large-scale construction, it was not been treated importantly at the general small-scale structures with poor ordering and original design was unchanged under construction was normal if the problem didn't occur on monitoring. In this paper, the site which safe and economical management as well as shortening construction period was made effectively using measurement result was introduced. Also, the site which was completed safely with analyzing measurement and reinforcement when unusual symptom happened was introduced. Using measurement result effectively will be able to obtain the safety and prevent unnecessary economical loss.

  • PDF

A Study on the Field Application of particulate matter Measurement Instruments in Light Scattering Method (광산란법 미세먼지 계측기의 현장 적용성 평가에 관한 연구 )

  • Liu, Bao-lin;Lee, Chung-Won;Lim, Hyo-Jin;Tae, Sung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.201-202
    • /
    • 2023
  • Now, there are many cases where materials are maintained at construction sites or standard construction prices are not in accordance with the applicable regulations, resulting in a lot of fine dust. Therefore, a particulate matter measurement system is applied not only to manage particulate matter at construction sites but also to reduce particulate matter .This study aims to evaluate the applicability of this particulate matter measurement system to the construction site through long-term measurement experiments using a light scattering method particulate matter measurement instrument at the construction site.

  • PDF

An Empirical Study on the Measurement of Size for Web-Page (웹페이지를 위한 규모측정에 관한 연구)

  • Kim, In-Suk;Lee, Nam-Yong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.52-54
    • /
    • 2003
  • Measurement is used to improve software process and to help calculating software quality. It makes software project to be control and help producing software. Measuring software scale becomes important target in software development. LOC is used to measure the size intentioned aspect and function point is used to measure the function intentioned aspect. This paper discusses measurement method using function point, which fullows proposed rule, and degree of GUI (Graphical User Interface) accesses achieved by applying this measurement to web page. Applying proposed rules to web pages (specially that use much GUI such as shopping mall or auction site), there is advantage that calculate site changes on numerical value by measuring GUI degree when do site administration or update.

  • PDF

A Case Study on the Feed-Back Analysis and the Reinforcement Plan using the Measurement Data of Excavation Site close to the Existing Underground Box (기존 지하 Box 근접 굴착공사 현장의 계측결과를 이용한 역해석 및 보강방안의 적용 사례)

  • Lee, Jung-Hee;Noh, Won-Seok;Jeong, Soon-Ig;Kim, Wan-Jong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.445-456
    • /
    • 2010
  • Massive underground excavation can be carried out recently due to the technical development of the excavation for retaining wall. Feed-back analysis using field measurement results is recommended to secure the stability of the construction because calculated values at stages of the design and the construction are uncertain. Reinforcement plan should be established based on the result of it. This study deals with the underground excavation site, which is under construction and is close to structure(subway) at downtown area. The result of feed-back analysis on the measurement data of displacement at multi-soil layers was reflected to make a plan for safe construction. This case study can be useful information for contingency plan on abnormal displacement which can be occurred at similar underground excavation.

  • PDF

Site Attenuations of an Open Area Test Site (야회시험장의 시험장감쇠량)

  • 김기채;정연춘;정정환;정낙삼
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1336-1343
    • /
    • 1990
  • In this paper the theoretical analysis of the site attenuation was made on the concept of mutual impedance of antennas and the cause of characteristic hump in the site attenuation curve below 80 MHz is explained. The deviation between the FCC site attenuatios and the experimental results of an ideal open area test site at low frequencies(below 80MHz) was found to be the mutual coupling effects of the antennas under the FCC's measurement conditions. It seems desirable that the site attenuations curve of FCC document be revicused to the theoretical curves presented in this paper is long as the FCC's measurement conditions are to the applied.

  • PDF

The DEVELOPMENT OF WORK PERFORMANCE ANALYSIS SYSTEM

  • Lim, Chul-Woo;Yu, Jung-Ho;Kim, Chang-Duk
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.738-746
    • /
    • 2009
  • The purpose of this study is to develop the web-based system for work performance analysis(WPAS). The need of work performance analysis system has already been suggested in many previous researches on the computerization of the performance measurement in the construction site by using the indicators such as time, cost and quality. However, they had focused on measuring or analyzing the result when the project would be over. The WPAS suggests three indicators - work reliability, work effectiveness and work efficiency - to manage the performance of the construction site. It can help the manager more easily recognize the status of on-going work in the construction site by measuring and analyzing the work reliability rate, the work effectiveness and work efficiency every day. This research includes the procedures for WPAS measurement process, database structure of WPAS which was analyzed by the IDEF0 and the data flow diagram. Finally, this research introduces the result of WAPS's case studies and validation in the Korean construction site.

  • PDF

On-site water level measurement method based on wavelength division multiplexing for harsh environments in nuclear power plants

  • Lee, Hoon-Keun;Choo, Jaeyul;Shin, Gangsig;Kim, Sung-Man
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2847-2851
    • /
    • 2020
  • A simple water level measurement method based on wavelength division multiplexing (WDM) is proposed and demonstrated. The measurement principle is based on the change of Fresnel reflection occurring at the end facet of the optical fiber tip (OFT). To increase the spatial resolution of water level sensing, a broadband light source (BLS) and an arrayed waveguide grating (AWG) are employed. The OFTs are multiplexed with the dedicated wavelength channels of AWG. By measuring all of the reflection powers reflected at the OFTs with a proposed on-site reflectometer, the water level can be monitored continuously for a fast emergency response. Moreover, it can be implemented easily with the commercially available optical components and devices with the simple configuration.