• Title/Summary/Keyword: On-line performance monitor

Search Result 74, Processing Time 0.042 seconds

Numerical Investigation of the Effect of flow Passage Variation on the Projection Distance of the Foam Monitor (유로형상변경에 따른 폼 모니터 분사거리 변화의 수치적 해석)

  • Lee, Young-Hoon;RYU, Young-Chun;Seong, Jeong-Hyun;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.244-251
    • /
    • 2016
  • In this study, the relationship between flow characteristics and projection distance, depending on the shape was examined. A numerical investigation technique for fluid analysis of a foam monitor was developed for the prediction, comparison and validation of the actual injection performance. The foam monitor changes the flow pattern of fluid flow according to the shape, The fluid losses were calculated from the numerical investigation affecting the projection distance. The basic form of foam monitor was used as a designed shape in N. The modified model used the length increase model of the flow path, and straight line of the model. The inlet pressure was 6.5bar. The results showed that the length increase model of the flow path and straight line of the model in the nozzle projection distance had improved. The results comparing the error rates projection performance were well matched to the 7.43% obtained from the validity test of the analysis method.

Study of On-line Performance Diagnostic Program of A Helicopter Turboshaft Engine (헬리콥터 터보축 엔진의 온라인 상태진단 프로그램 연구)

  • Kong, Chang-Duk;Koo, Young-Ju;Kho, Seong-Hee;Ryu, Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.12
    • /
    • pp.1238-1244
    • /
    • 2009
  • This work proposes a GUI-type on-line diagnostic program using SIMULINK and Fuzzy-Neuro algorithms for a helicopter turboshaft engine. During development of the diagnostic program, a look-up table type base performance module for reducing computer calculating time and a signal generation module for simulating real time performance data are used. This program is composed of the on-line condition monitoring program to monitor on-line measuring performance condition, the fuzzy inference system to isolate the faults from measuring data and the neural network to quantify the isolated faults. The reliability and capability of the proposed on-line diagnostic program were confirmed through application to the helicopter engine health monitoring.

Samsung's $4^{th}$ Generation TFT- LCD Production Line Concept

  • Chang, Won-Kie
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2001.08a
    • /
    • pp.9-12
    • /
    • 2001
  • With the explosive growth of Note-PC and Desktop monitor market, TFT LCD market confronted a entire supply shortage during 1999. Forecasting a more booming stage for the next several years, many TFT-LCD panel manufacturers continue to expand the capacity of their existing plants and also make an additional investment in building new plants. The new investment is concentrated on the $4^{th}$ generation TFT LCD line in order to improve investment efficiency. The set up of the Samsung's Gen 3.5 line progressed with satisfactorily performance using $600{\times}720mm$ glass size. We have continuously reviewed several issues regarding the glass size for our next Gen. 4 line, which leads to adopt $730{\times}920mm$. Due to the continuous enlargement of a substrate size and following difficulty in transferring cassettes, the next line is expected to be the last line that employs "cassette transfer". The layout of the next line will shift from conventional "concentration-type" to "separation-type" configuration for the purpose of reducing transfer distance as well as transfer time. The details will be discussed in this paper.

  • PDF

VALIDATION OF ON-LINE MONITORING TECHNIQUES TO NUCLEAR PLANT DATA

  • Garvey, Jamie;Garvey, Dustin;Seibert, Rebecca;Hines, J. Wesley
    • Nuclear Engineering and Technology
    • /
    • v.39 no.2
    • /
    • pp.133-142
    • /
    • 2007
  • The Electric Power Research Institute (EPRI) demonstrated a method for monitoring the performance of instrument channels in Topical Report (TR) 104965, 'On-Line Monitoring of Instrument Channel Performance.' This paper presents the results of several models originally developed by EPRI to monitor three nuclear plant sensor sets: Pressurizer Level, Reactor Protection System (RPS) Loop A, and Reactor Coolant System (RCS) Loop A Steam Generator (SG) Level. The sensor sets investigated include one redundant sensor model and two non-redundant sensor models. Each model employs an Auto-Associative Kernel Regression (AAKR) model architecture to predict correct sensor behavior. Performance of each of the developed models is evaluated using four metrics: accuracy, auto-sensitivity, cross-sensitivity, and newly developed Error Uncertainty Limit Monitoring (EULM) detectability. The uncertainty estimate for each model is also calculated through two methods: analytic formulas and Monte Carlo estimation. The uncertainty estimates are verified by calculating confidence interval coverages to assure that 95% of the measured data fall within the confidence intervals. The model performance evaluation identified the Pressurizer Level model as acceptable for on-line monitoring (OLM) implementation. The other two models, RPS Loop A and RCS Loop A SG Level, highlight two common problems that occur in model development and evaluation, namely faulty data and poor signal selection

A Study on the Work Management Method Considering Risks in Nuclear Power Plants (원자력발전소에서 리스크를 고려한 작업관리 방법)

  • Song, Tae-Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • Nuclear power plants(NPPs) are consisted of power production functions and safety functions preventing leakage of radiation. Operators working in NPPs shall maintain these functions during an operation period through various activities such as improvement & modification, corrective maintenance, preventive maintenance and surveillance test. According to the performance of these work activities, there are configuration changes in NPPs systems. Its changes cause the increase of safety risks(CDF) and plant trip risks. Recently, the importance of risk management is increasing gradually in the operation process of NPPs. Therefore, this paper presents the work management methods using the various risk monitoring systems during power operation and overhaul period. Also this paper suggests the optimum application ways of risk systems for work management.

A Study on GUI type On-line Condition Monitoring Program for A Turboprop Engine Using LabVIEW$^{(R)}$ (LabVIEW를 이용한 터보프롭 엔진의 GUI기반 온라인 상태감시 프로그램에 관한 연구)

  • Kong, Chang-Duk;Kim, Keon-Woo;Kim, Ji-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.86-93
    • /
    • 2011
  • Recently, development and application of condition monitoring and diagnostic system for improvement of durability and reliability and reduction of operating cost is generalized in the aircraft propulsion system. Expecially, for reliable operation of the high altitude and a long time and condition monitoring system to identify faults and degradations of its propulsion system should be needed. This work proposed a GUI-based On-line condition monitoring program using LabVIEW by PT6A-67 turboprop engine. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between performance results calculated by the base performance simulation program and measuring engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed on-line monitoring system.

인공 신경망 제어기에 의한 생물공정에서 암모니아 농도의 제어

  • Lee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.173-176
    • /
    • 2000
  • A neural network based controller (NN controller) was studied for the control of ammonia concentrations in biological processes. An ammonia FIA has been employed to on-line monitor the concentrations of ammonia in a bioreactor. The optimal neural network structure was investigated by computer simulation and found to be a 3(inputlayer)-2(hidden layer)-1(output layer). The NN controller had advantage over the PID controller, even though the former is more time consuming. The 3-2-1 NN controller has been used to control the ammonia concentrations in a simulated bioprocess and also in a real cultivation process of yeast, and its performance were investigated.

  • PDF

The Design and Implementaion of On-Line Performance Monitor for JaNeC (JaNeC을 위한 온라인 성능감시기의 설계 및 구현)

  • 김남훈;김명호;최재영
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10c
    • /
    • pp.618-620
    • /
    • 2000
  • 최근 네트워크를 이용한 분산환경에서의 작업이 늘고 있다. 이러한 네트워크 환경에서의 병렬프로그램은 그 수행 과정이 일반 순차 프로그램보다 복잡해서 프로그램 진행과정을 파악하기가 어렵다. 그래서 병렬프로그램을 쉽게 분석할 수 있도록 성능감시기에 대한 연구가 진행되고 있다. 이에 본 논문에서는 JaNeC 환경에서 동작하는 병렬프로그램의 진행과정을 이벤트가 발생하는 동안에 실시간으로 볼 수 있도록 온라인 성능감시기에 대해서 설명한다.

  • PDF

A Boundary-Scan Based On-Line Circuit Performance Monitoring Scheme (경계 스캔 기반 온-라인 회로 성능 모니터링 기법)

  • Park, Jeongseok;Kang, Taegeun;Yi, Hyunbean
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.51-58
    • /
    • 2016
  • As semiconductor technology has developed, device performance has been improved. However, since device structures became smaller, circuit aging due to operational and environmental conditions can be accelerated. Circuit aging causes a performance degradation and eventually a system error. In reliable systems, a failure due to aging might cause a great disaster. Therefore, these systems need a performance degradation prediction function so that they can take action in advance before a failure occurs. This paper presents an on-line circuit performance degradation monitoring scheme for predicting a failure by detecting performance degradation during circuit normal operation. In our proposed scheme, IEEE 1149.1 output boundary scan cells and TAP controller are reused. The experimental result shows that the proposed architecture can monitor the performance degradation during normal operation without stopping the circuit.

Development of a 30-in. wide-QXGA+ TFT-LCD for High-Information-Content Displays

  • Choi, H.C.;Hong, S.G.;Lim, B.H.;Lee, S.W.;Yeo, S.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.19-22
    • /
    • 2004
  • A 30-inch WQXGA+ TFT-LCD Monitor has been developed based on in-plane switching mode with multi-domain. This product adopts Cu electrode which, in spite of low resistivity, was not applied to TFT LCD products because of productivity and reliability problems etc. This low resistivity material makes it possible to clear the problem caused by line delay in such high resolution TFT-LCDs. As a results of successful adoption of innovative materials and technologies, our world's largest TFT-LCD Monitor has best performance for high information display.

  • PDF