• Title/Summary/Keyword: On-line monitoring system

Search Result 761, Processing Time 0.027 seconds

Implementation of the 155.52 MHz Clock Recovery Receiver for the Fiber Optic Modules (광통신 모듈용 155.52 MHz 클럭복원 리시버의 구현)

  • 이길재;채상훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12C
    • /
    • pp.249-254
    • /
    • 2001
  • A receiver ASIC for fiber optic modules of STM-1 optical communication has been fabricated with 0.65 $\mu\textrm{m}$ CMOS technology. The ASIC has a limit amplifier circuit for the 155.52 Mbps data reshaping, and a clock extraction circuit for the 155.52 MHz clock recovery. The ASIC has an acquisition aid and LOS monitoring circuit for properly operation with near 155.52 MHz clock frequency in case of the data loss due to transmission line open or data transfer fail. Measured results show that the circuit reshapes data from 5 mV to 1 V wide range of input voltage condition, add it recovers system clock with stable on any condition.

  • PDF

A study on monitoring the subsidence of the gas utilities using GPS techniques (GPS를 이용한 가스설비 침하 감시 기술 연구)

  • Cho S.H.;Jeon K.S.;Park P.H.;Park J.U.;Joh J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.53-61
    • /
    • 1999
  • The safety of gas utilities is intimidated by many causes. Among them, subsidence is a dominant cause to decrease the safety of gas utilities. So it is very important to monitor the displacement of subsidence. The purpose of this study is to on-line monitor the subsidence of gas utilities using Static GPS(Global Positioning System)technique. Static GPS technique, which is one of various GPS techniques and originally applied to monitor the crustal activity, was applied for two gas station in Korea Gas Corporation. Prior to applying this technique to the field, i.e, gas station, a preliminary test was peformed to confirm the accuracy of this technique. As a result, it was proved that this technique can measure the displacement of gas utilities three dimensionally by sub-millimeter. After getting confirmation of GPS technique, we applied this technique for two gas stations and monitored the amount of subsidence during 5 months. As a result of field test, we can conclude that the gas stations was subsiding several millimeters in a year.

  • PDF

Video Image Analysis in Accordance with Power Density of Arcing for Current Collection System in Electric Railway (전기철도 집전장치의 아크량에 따른 비디오 이미지 분석)

  • Park, Young;Lee, Kiwon;Park, Chulmin;Kim, Jae-Kwang;Jeon, Ahram;Kwon, Sam-Young;Cho, Yong Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1343-1347
    • /
    • 2013
  • This paper presents an analysis methods for current collection quality in catenary system by means of video image based monitoring system. Arcing is the sparking at the interface point between pantograph and contact wire when the electric trains have traction current values at speed. Percentage of arcing at maximum line speed is measurable parameters for compliance with the requirements on dynamic behaviour of the interface between pantograph and contact wire in accordance with requirement of IEC and EN standards. The arc detector and video is installed on a train aim at the trailing contact strip according to the travel direction. The arc detector presented and measured verity of value such as the duration and power density of each arc and the video image is measured a image when the arc is occurred in pantograph. In this paper we analysis of video image in accordance with power density of arcing from arc detector and compared with video image and power density of arcing so as to produce quality of arcing from image.

Elastic Wave Detection using Fiber Optic FBG Sensor (광섬유 FBG 센서를 이용한 탄성파 검출)

  • Seo, Dae-Cheol;Kwon, Il-Bum;Yoon, Dong-Jin;Lee, Seung-Suk;Lee, Jung-Ryul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • Acoustic emission(AE) has emerged as a powerful nondestructive tool to detect or monitor preexisting defects and leaks in the vessel structures. A Bragg grating based acoustic emission sensor system is developed. Various type of fiber Bragg grating sensor including the variable length of sensing part was fabricated and prototype sensor system was tested by using PZT pulser and pencil lead break sources. Two types of sensor attachment were used. First, the fiber Bragg grating sensor was attached fully to the surface using bonding agent. Second one is that one part of fiber was attached to the surface partly by bonding and the other part of fiber will be act as a cantilever. That is, the resonant frequency of the fiber Bragg grating sensor will depend on the length of sensing part. The final goal of the sensor system is to provide on-line monitoring of cracks or leaks in reactor vessel head penetration of nuclear power plants.

Base Flow Estimation in Uppermost Nakdong River Watersheds Using Chemical Hydrological Curve Separation Technique (화학적 수문곡선 분리기법을 이용한 낙동강 최상류 유역 기저유출량 산정)

  • Kim, Ryoungeun;Lee, Okjeong;Choi, Jeonghyeon;Won, Jeongeun;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.489-499
    • /
    • 2020
  • Effective science-based management of the basin water resources requires an understanding of the characteristics of the streams, such as the baseflow discharge. In this study, the base flow was estimated in the two watersheds with the least artificial factors among the Nakdong River watersheds, as determined using the chemical hydrograph separation technique. The 16-year (2004-2019) discontinuous observed stream flow and electrical conductivity data in the Total Maximum Daily Load (TMDL) monitoring network were extended to continuous daily data using the TANK model and the 7-parameter log-linear model combined with the minimum variance unbiased estimator. The annual base flows at the upper Namgang Dam basin and the upper Nakdong River basin were both analyzed to be about 56% of the total annual flow. The monthly base flow ratio showed a high monthly deviation, as it was found to be higher than 0.9 in the dry season and about 0.46 in the rainy season. This is in line with the prevailing common sense notion that in winter, most of the stream flow is base flow, due to the characteristics of the dry season winter in Korea. It is expected that the chemical-based hydrological separation technique involving TANK and the 7-parameter log-linear models used in this study can help quantify the base flow required for systematic watershed water environment management.

Modal Parameter Extraction of Seohae Cable-stayed Bridge : I. Mode Shape (서해대교 사장교의 동특성 추출 : I. 모드형상)

  • Kim, Byeong Hwa;Park, Min Seok;Lee, Il Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.631-639
    • /
    • 2008
  • This paper reports the mode shapes of Seohae cable-stayed bridge extracted by TDD technique. In order to record total 72 acceleration points in the vertical direction of the bridge deck, a custom made data acquisition system with LAN communication has been especially developed and a set of ambient vibration tests has been conducted. For the measured acceleration responses, total twenty four mode shapes up to 2Hz has been extracted by TDD technique. The extracted mode shapes include many new modes that have not been identified in the current on-line health monitoring system installed in the bridge. It is confirmed that TDD technique is the most effective in extracting the high resolution mode shapes on a particularly long span bridge.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

A Study on the Interface between DAS and SCADA by using Direct Method (직접연계방법에 의한 DAS-SCADA 연계 연구)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1154-1163
    • /
    • 2008
  • DAS and SCADA system are main systems, which operate and manage the power system by using computer and communication technology. But DAS and SCADA have been operated independently in Korea, so there was some time delay in the fault handling and live-line work. To improve that problems, studies on the interface between DAS and SCADA have been needed. From November 2005 to December 2007, the pilot project has been performed in KEPCO's branch offices, as a result, direct method will be applied widely all over the country until 2010 because the operation information of substation users want can be transmitted fast and it is possible to control 43RC directly although the expense for direct method is about 1.3 times larger than that for web method. To improve problems revealed during the pilot project, substation object to object communication method is proposed and interface database automatic generation and interface system diagnosis and logging functions are developed. Interface data point and communication data type are defined, substation single line diagram automatic generation or manual editing function, SCADA monitoring and controlling function, log data managing function are developed in SCADA HMI program. It is expecting to reduce the average time for each outage about 33% and to improve the reliability, efficiency of operation, execution of DAS from automatic load transfer under a fault, and to contribute to export project.

Use of Single-System Design to Evaluate the Effectiveness of Cognitive Behavioral Therapy of Depression (임상실천 평가를 위한 단일체계설계의 적용 -우울증 감소를 위한 인지행동치료에 대한 평가를 중심으로-)

  • Kim, Yong-Seok;Shon, Dong-Gyun
    • Korean Journal of Social Welfare
    • /
    • v.60 no.2
    • /
    • pp.175-209
    • /
    • 2008
  • The purpose of this study, which has its focus on the utilization of single-system design for practice evaluation, is to evaluate the effectiveness of cognitive behavioral therapy of depression by using a AB design. 3 inpatients in a local hospital with a diagnosis of major depressive disorder agreed to participate in this study. The AB design includes a 2weeks of the baseline phase and 3 weeks of the intervention phase. More than one outcome measures were used in order to validate the results of the measurement. Data were analyzed statistically as well as visually. Tools such as trend line and trend index were used to improve the accuracy of the visual analysis and the 3 standard deviation approach was used for statistical significance test. The results showed that all clients improved. This study lists some advantages of using single-system design for evaluating clinical practice: monitoring, encouraging clients' active role in social work process, and easy data analysis.

  • PDF

Development of an Automated Control System for Bioreactor using the Plant Tissue Culture (식물조직배양용 바이오리액터의 농도제어 시스템 개발)

  • Chung, Seok-Hyun;No, Daehyun;Kang, Changho;Kang, Sukwon;Han, Bong-Hee;Lee, Gee-Myung;Na, Young-Sun
    • Journal of Plant Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.307-312
    • /
    • 2004
  • The bioreactor system for the large-scale plant tissue culture was developed to control the pH concentration and DO (dissolved oxygen), and air flowrate. The system controlling the proper air flow rate for each bulblet growth stage and monitoring the contamination of bioreactor using the pH change was controled by computer program. For the uniform bulblet distribution in bioreactor, the proper air flow rate was 300 cc/min at the beginning of bulblet culture, 400 cc/min after 20 days, 500 cc/min after 40 days, 600 cc/min after 60days, and 700 cc/min after 80 days. It was possible to maintain the pH concentration within 5.5$\pm$0.5 during the culture by control system of bioreactor.