• 제목/요약/키워드: On-line monitor

검색결과 384건 처리시간 0.026초

TCMS에 의한 전동차 추진/제동 제어기법 (A Study of Train Powering/Braking Control by TCMS)

  • 한정수;박성호;김국진;박계서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.291-298
    • /
    • 1999
  • TCMS(Train Control & Management System) is the management system of train information which intensively control, monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, in comparison with the powering/braking control by conventional relay logic/hardwire circuits, and the software logic was verified by simulation test with TCMS simulator.

  • PDF

PCS폰을 이용한 인터넷기반 3차원 원격 모니터링 시스템 개발 (Development of Internet-Based 3-Dimensional Remote Monitoring System By Using PCS Phone)

  • 김주환;김성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2212-2215
    • /
    • 2001
  • Nowadays, environmental protection is increasingly concerned more than ever before. Therefore, it is prerequisite both to monitor some data and control them on-line for reducing the environmental pollution. In this paper, internet-based 3-dimensional monitoring system which utilizes PCS phones for wireless data communication with server computer is presented and its feasibility is tested by physical installation.

  • PDF

On-line Generation of Three-Dimensional Core Power Distribution Using Incore Detector Signals to Monitor Safety Limits

  • Jang, Jin-Wook;Lee, Ki-Bog;Na, Man-Gyun;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.528-539
    • /
    • 2004
  • It is essential in commercial reactors that the safety limits imposed on the fuel pellets and fuel clad barriers, such as the linear power density (LPD) and the departure from nucleate boiling ratio (DNBR), are not violated during reactor operations. In order to accurately monitor the safety limits of current reactor states, a detailed three-dimensional (3D) core power distribution should be estimated from the in-core detector signals. In this paper, we propose a calculation methodology for detailed 3D core power distribution, using in-core detector signals and core monitoring constants such as the 3D Coupling Coefficients (3DCC), node power fraction, and pin-to-node factors. Also, the calculation method for several core safety parameters is introduced. The core monitoring constants for the real core state are promptly provided by the core design code and on-line MASTER (Multi-purpose Analyzer for Static and Transient Effects of Reactors), coupled with the core monitoring program. through the plant computer, core state variables, which include reactor thermal power, control rod bank position, boron concentration, inlet moderator temperature, and flow rate, are supplied as input data for MASTER. MASTER performs the core calculation based on the neutron balance equation and generates several core monitoring constants corresponding to the real core state in addition to the expected core power distribution. The accuracy of the developed method is verified through a comparison with the current CECOR method. Because in all the verification calculation cases the proposed method shows a more conservative value than the best estimated value and a less conservative one than the current CECOR and COLSS methods, it is also confirmed that this method secures a greater operating margin through the simulation of the YGN-3 Cycle-1 core from the viewpoint of the power peaking factor for the LPD and the pseudo hot pin axial power distribution for the DNBR calculation.

Carbon fiber-based long-gauge sensors monitoring the flexural performance of FRP-reinforced concrete beams

  • Mohamed A. Saifeldeen;Nariman Fouad
    • Structural Monitoring and Maintenance
    • /
    • 제10권4호
    • /
    • pp.299-314
    • /
    • 2023
  • Long-gauge carbon fiber line (CFL) sensors have received considerable attention in the past decade. However, there is still a need for an in-depth investigation of their measuring accuracy. This study investigates the accuracy of carbon fiber line sensors to monitor and differentiate the flexural behavior of two beams, one reinforced with steel bars alone and the other reinforced with steel and basalt fiber-reinforced polymer bars. A distributed set of long-gauge carbon fiber line, Fiber Bragg Grating (FBG), and traditional strain gauge sensors was mounted on the tensile concrete surface of the studied beams to compare the results and assess the accuracies of the proposed sensors. The test beams were loaded monotonically under four-point bending loading until failure. Results indicated the importance of using long-gauge sensors in providing useful, accurate, and reliable information regarding global structural behavior, while point sensors are affected by local damage and strain concentrations. Furthermore, long-gauge carbon fiber line sensors demonstrated good agreement with the corresponding Fiber Bragg Grating sensors with acceptable accuracy, thereby exhibiting potential for application in monitoring the health of large-scale structures.

VALIDATION OF ON-LINE MONITORING TECHNIQUES TO NUCLEAR PLANT DATA

  • Garvey, Jamie;Garvey, Dustin;Seibert, Rebecca;Hines, J. Wesley
    • Nuclear Engineering and Technology
    • /
    • 제39권2호
    • /
    • pp.133-142
    • /
    • 2007
  • The Electric Power Research Institute (EPRI) demonstrated a method for monitoring the performance of instrument channels in Topical Report (TR) 104965, 'On-Line Monitoring of Instrument Channel Performance.' This paper presents the results of several models originally developed by EPRI to monitor three nuclear plant sensor sets: Pressurizer Level, Reactor Protection System (RPS) Loop A, and Reactor Coolant System (RCS) Loop A Steam Generator (SG) Level. The sensor sets investigated include one redundant sensor model and two non-redundant sensor models. Each model employs an Auto-Associative Kernel Regression (AAKR) model architecture to predict correct sensor behavior. Performance of each of the developed models is evaluated using four metrics: accuracy, auto-sensitivity, cross-sensitivity, and newly developed Error Uncertainty Limit Monitoring (EULM) detectability. The uncertainty estimate for each model is also calculated through two methods: analytic formulas and Monte Carlo estimation. The uncertainty estimates are verified by calculating confidence interval coverages to assure that 95% of the measured data fall within the confidence intervals. The model performance evaluation identified the Pressurizer Level model as acceptable for on-line monitoring (OLM) implementation. The other two models, RPS Loop A and RCS Loop A SG Level, highlight two common problems that occur in model development and evaluation, namely faulty data and poor signal selection

Monitoring changes in the genetic structure of Brown Tsaiya duck selected for feeding efficiency by microsatellite markers

  • Yi-Ying Chang;Hsiu-Chou Liu;Chih-Feng Chen
    • Animal Bioscience
    • /
    • 제36권3호
    • /
    • pp.417-428
    • /
    • 2023
  • Objective: Few studies have genetically monitored chickens over time, and no research has been conducted on ducks. To ensure the sustainable management of key duck breeds, we used microsatellite markers to monitor Brown Tsaiya ducks over time genetically. Methods: The second, fourth, sixth to eighth generations of the Brown Tsaiya duck selected for feeding efficiency and control lines were included in this study to investigate the genetic variations, effective population size, population structure and the differentiation between populations over time with 11 microsatellite markers derived from Brown Tsaiya duck. Results: The results showed there were a slight decrease in the genetic variations and an increase in within-population inbreeding coefficient (FIS) in both lines, but no consistent increase in FIS was observed in each line. The effective population size in the second and eighth generations was 27.2 for the selected line and 23.9 for the control line. The change in allele richness showed a downward trend over time, and the selected line was slightly lower than the control line in each generation. The number of private alleles (Np) in the selected line were higher than in the control line. Moderate differentiation was observed between the second and eighth generations in the selected line (FST = 0.0510) and the control line (FST = 0.0606). Overall, differentiation tended to increase with each generation, but genetic variation and structure did not change considerably after six generations in the two lines. Conclusion: This study provides a reference for poultry conservation and helps to implement cross-generation genetic monitoring and breeding plans in other duck breeds or lines to promote sustainable management.

생산라인용 자동차 변속기용 헬리컬 기어 검사 장치에 관한 연구 (A Study on the Helical Gear Inspection System for Vehicle Transmission Gear Manufacturing Line)

  • 이민기;이응석;김기남;김광중
    • 대한기계학회논문집A
    • /
    • 제34권2호
    • /
    • pp.237-243
    • /
    • 2010
  • 본 논문은 자동차 변속기의 헬리컬기어 검사 장치에 대한 것이다. 기어 프로파일 전용 검사설비는 시간이 많이 소요되므로 생산라인용으로 적합하지 못하다. 본 논문에서 사용된 마스트기어를 이용하여 생산된 기어와 비교하여 방법은 보다 경제적이며 효율적이다. 본 논문에 사용된 3가지 기어검사 파라미터는 nick, 흔들림(run-out) 및 PCD (pitch circle diameter) 등이다. 기어검사장치의 측정정밀도에 영향을 미치는 요소들에 대해서도 또한 언급되었다. 이 장치는 현재 국내에서 전량 수입되는 기어 생산라인용 설비에 실제적으로 사용될 것이다.

학교 컴퓨터실의 전기안전에 대한 리스크요소 평가 (Assessment of Risk Component for Electrical Safety of Computer Room in School)

  • 길형준;김동욱;이기연;김향곤;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.440-445
    • /
    • 2007
  • This paper deals with assessment of risk component for electrical safety and investigation on the spot of computer room in elementary middle high school. The investigation was carried out side by side for floor, outlet, panel board, earth leakage circuit breaker at computer room In order to assess electrical safety at computer room, grounding simulator and power quality monitor have been used. Potential rise has been measured and analyzed for ground rod and grounding grid by using the simulator. Phase and neutral-line current have been monitored in real time. As a consequence, it is desirable for us to install conductive tile at floor of computer room Grounding grid had better than ground rod for electrical safety. Neutral-line current was produced by unbalanced phase current.

  • PDF

LabVIEW를 이용한 원격 Motion Control에 관한 연구 (A Study on Remote Motion Control by using LabVIEW)

  • 지면호;권순재;정영석;손정기;김태화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.677-680
    • /
    • 2002
  • The biggest obstacle in utilizing Telerobotics is that an exclusive line is necessary to connect the distant place and manipulator for the purpose of remote control. Moreover, installment of an exclusive line Is limited to relatively short distance, as the installment entails more difficulties with longer distance and increasing installment cost. The purpose of this paper is to suggest a methodology of factory automation by using Lab VIEW to control and monitor actuators, which are the basis of controlling manipulators, form distant places.

  • PDF

On the Study of Telephone Based Home Monitoring System

  • Alom, Md. Zahangir;Du, Ruoyu;Lee, Hyo Jong
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 추계학술발표대회
    • /
    • pp.958-961
    • /
    • 2010
  • We can monitor home from any remote location using our existing telephone line. We have already some technologies to perform these types of application such as: Bluetooth, IR. But these are used in a limited area which we can easily come over in our system. Our propose system has two sections one is Remote Section (RS) where the client will place the request and another is Local Section (LS) where the telephone line is connected with an Input Interfacing Circuit (IIC). Input Interfacing Circuit (IIC) receives the frequency and converts frequency to machine language. Output Interfacing Circuit (OIC) sends voice signal to the client as acknowledgement through modem then the client proceeds for the next steps. This system can be used in commercial or industrial purposes such as controlling computer from remote locations, home monitoring system instead of man or any kind of switching.