• Title/Summary/Keyword: On-line monitor

Search Result 383, Processing Time 0.028 seconds

CYTOTOXIC EFFECT OF RETROGRADE FILLING MATERIALS INCLUDING GLASS IONMER CEMENT ACCORDING TO CELL LINES AND ASSAY METHODS (광중합형 glass ionomer cement를 포함한 수종 역충전재의 세포주와 검사법에 따른 독성 효과)

  • Im, Mi-Kyung;Koo, Dae-Hoi
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.403-424
    • /
    • 1996
  • Cell culture methods have been used to assess the cytotoxicity of dental materials. Different paramaters are used to monitor cytotoxic effects. But it is difficult to compare each investigator's results with different methods. The objective of this study was to investigate cytotoxic effect of several retrograde filling materials according to cell lines and assay methods. Cytotoxicity of Bestalloy (Dogmyung, Korea), Prisma APH(Densply International Inc., U.S.A.), Clearfil FII (Kuraray Co., Japan), Fuji II (GC Co., Japan), Fuji II LC (GC Co., Japan) and IRM (Densply Co., U.S.A.) on L929, 3T3 and KB permanent cell lines was measured. Radiochromium, Lactate dehydrogenase (LDH) release method and colorimetric assays, namely neutral red (NR) and MTT were used. Each material was mixed according to the manufacturer's instruction. They were tested as solid and extracted state. Cell culture media were added to each mixed or solid materials then the solution was collected and used as extract solutions. Solid Fuji II showed mild cytotoxicity on three cell lines using radiochromium release method. There was no difference in cytotoxicity of extract solution group using radiochromium release method. In colorimetric assay immediate Fuji II group and all the IRM groups showed severe cytotoxic effect. Difference in cyctotoxicity was due to rather kinds of cell lines than assay methods. Solid Fuji II and IRM showed mild cytotoxicity on three cell lines. But extract solutions had different cytotoxic effect according to cell lines using LDH release assay. Light-cured glass ionomer had mild to moderate degree of cytotoxicity on three cell lines. Cytotoxicity was affected by specimen prepaton. Susceptibility of each cell ines were also affected by assay emthods. It was suggested that cytotoxicity study using only one cell line and/or assay method might not accurately reflect the real toxic nature of dental biomaterials.

  • PDF

A Design of Scalable SNMP Agent Bundle Based on OSGi Framework (OSGi 프레임워크기반 확장형 SNMP 에이전트 번들 설계)

  • Hwang Tae-In;Park Kwang-Roh
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.1 no.1
    • /
    • pp.40-50
    • /
    • 2002
  • A traditional agent was difficult to upgrade and to add MIB implementation code to it because most SNMP agent designs had MIB that was not a self-contained module. To solve this problem, we design the SNMP agent bundle composed of remotely uploadable SNMP agent core bundle and MIB Bundle Also, downloadable server bundle and user administration bundle is added to SNMP agent bundle to download MIB bundle from bundle server. By designing MB-MIB, we enable the network manager to monitor status of MIB bundle on managed devices. The network manager is allowed to install and upgrade the SNMP module or MIB remotely on line. This is the major benefit of designing the SNMP agent bundle based on OSGi. Finally, we expect the network manager to reduce time and expenses in managing enormous networks by using the SNMP agent bundle.

  • PDF

Leak Detection and Evaluation for Power Plant Boiler Tubes Using Acoustic Emission (음향방출을 이용한 보일러튜브 누설평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.45-51
    • /
    • 2004
  • Boiler tubes in power plants are often leaked due to various material degradations including creep and thermal fatigue damage under severe operating conditions such as high temperature and high pressure over an extended period of time. To monitor and diagnose the tubes on site and in real time, the acoustic emission (AE) technology was applied. We developed an AE leak detection system, and used it to study the variation of AE signal from the on-site tubes in response to the changes in the boiler operation condition and to detect the locations of leakage based on it. Detection of leak was performed by acquiring and evaluating the signals in separate regimes of high and low frequency signal. As a result of these studies, we found that on-line monitoring and detection of leak location for boiler tubes is possible using the developed system. Thus, the system is expected to contribute to the safe operation of power plants, and prevent economic losses due to potential leak.

Control of Ammonium Concentration in Biological Processes Using a Flow Injection Analysis Technique (흐름주입분석기술을 이용한 생물공정에서 암모니아 농도의 제어)

  • 이종일
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.452-458
    • /
    • 2001
  • Concentrations of ammonia in biological processes were controlled by PID controllers and also neural network based controllers (NN controllers). A flow injection analysis system has been to on-line monitor the concentrations of ammonia in a bioreactor. The effect of the analysis error and the residence time of samples on the control performance were studied. The optimal neural network structure was investigated by using computer simulation and found to be a 3(input layer)-2(hidden layer)-1(output layer). The NN controller is often time consuming, but it has advantage over the PID controller in sensitivity. The 3-2-1 NN controller has been applied to control the ammonia concentrations in a simulated bioprocess and also a real cultivation process of yeast. The good control performance showed that the 3-2-1 NN controller based on the FIA system can be used to control the concentration of substrates in biological processes very well.

  • PDF

Monitoring Network Security Situation Based on Flow Visualization (플로우 시각화 기반의 네트워크 보안 상황 감시)

  • Chang, Beom-Hwan
    • Convergence Security Journal
    • /
    • v.16 no.5
    • /
    • pp.41-48
    • /
    • 2016
  • In this paper we propose a new method of security visualization, VisFlow, using traffic flows to solve the problems of existing traffic flows based visualization techniques that were a loss of end-to-end semantics of communication, reflection problem by symmetrical address coordinates space, and intuitive loss problem in mass of traffic. VisFlow, a simple and effective security visualization interface, can do a real-time analysis and monitoring the situation in the managed network with visualizing a variety of network behavior not seen in the individual traffic data that can be shaped into patterns. This is a way to increase the intuitiveness and usability by identifying the role of nodes and by visualizing the highlighted or simplified information based on their importance in 2D/3D space. In addition, it monitor the network security situation as a way to increase the informational effectively using the asymmetrical connecting line based on IP addresses between pairs of nodes. Administrator can do a real-time analysis and monitoring the situation in the managed network using VisFlow, it makes to effectively investigate the massive traffic data and is easy to intuitively understand the entire network situation.

Stereoscopic Contents Production Workflow Based on Nonlinear Editing (비선형 편집기반의 입체영상 제작 흐름에 관한 연구)

  • Kim, Chul-Hyun;Paik, Joon-Ki
    • Journal of Broadcast Engineering
    • /
    • v.15 no.3
    • /
    • pp.391-406
    • /
    • 2010
  • Digital cinema based on digital master distribution increases with stereoscopic film as the center. DCI specification V1.0 announced at 2004, it considerates stereoscopic film screening. And now, the Society of Motion Picture and Television Engineers is establishing a task force to define the standards of a stereoscopic contents viewed in the home. Today, most Hollywood commercial stereoscopic film features animation using computer graphic. However, considering film making characteristic, stereoscopic digital cinema is required shooting in real world and editing, screening. This paper presents possibility of stereoscopic examination at NLE in the stereoscopic workflow. And we will propose new stereoscopic digital cinema workflow to apply the stereoscopic examination. Based on experimental results, the 3D ready television using 120Hz has some obstacles for contents editing, but most domestic stereoscopic monitor using circular polarization is possible for successful editing.

Analysis of a Simulated Optical GSO Survey Observation for the Effective Maintenance of the Catalogued Satellites and the Orbit Determination Strategy

  • Choi, Jin;Jo, Jung Hyun;Yim, Hong-Suh;Choi, Young-Jun;Son, Ju-Young;Park, Sun-youp;Bae, Young-Ho;Roh, Dong-Goo;Cho, Sungki
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.237-245
    • /
    • 2015
  • A strategy is needed for a regional survey of geosynchronous orbits (GSOs) to monitor known space objects and detect uncataloged space objects. On the basis of the Inter-Agency Debris Committee's recommendation regarding the protected region of geosynchronous Earth orbit (GEO), target satellites with perigee and apogee of $GEO{\pm}200km$ and various inclinations are selected for analysis. The status of the GSO region was analyzed using the satellite distribution based on the orbital characteristics in publicly available two-line element data. Natural perturbation effects cause inactive satellites to drift to two stable longitudinal points. Active satellites usually maintain the designed positions as a result of regular or irregular maneuver operations against their natural drift. To analyze the detection rate of a single optical telescope, 152 out of 412 active satellites and 135 out of 288 inactive satellites in the GSO region were selected on the basis of their visibility at the observation site in Daejeon, Korea. By using various vertical view ranges and various numbers of observations of the GSO region, the detection efficiencies were analyzed for a single night, and the numbers of follow-up observations were determined. The orbital estimation accuracies were also checked using the arc length and number of observed data points to maintain the GSO satellite catalog.

System Networking for the Monitoring and Analysis of Local Climatic Information in Alpine Area (강원고랭지 농업기상 감시 및 분석시스템 구축)

  • 안재훈;윤진일;김기영
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.3
    • /
    • pp.156-162
    • /
    • 2001
  • In order to monitor local climatic information, twelve automated weather stations (AWS) were installed in alpine area by the Alpine Agricultural Experiment Station, Rural Development Administration (RDA), at the field of major crop located in around highland area, and collected data from 1993 to 2000. Hourly measurements of air and soil temperature (underground 10 cm,20 cm), relative humidity, wind speed and direction, precipitation, solar radiation and leaf wetness were automatically performed and the data could be collected through a public phone line. Datalogger was selected as CR10X (Campbell scientific, LTD, USA) out of consideration for sensers' compatibility, economics, endurance and conveniences. All AWS in alpine area were combined for net work and daily climatic data were analyzed in text and graphic file by program (Chumsungdae, LTD) on 1 km $\times$ 1 km grid tell basis. In this analysis system, important multi-functionalities, monitoring and analysis of local climatic information in alpine area was emphasized. The first objective was to obtain the output of a real time data from AWS. Secondly, daily climatic normals for each grid tell were calculated from geo-statistical relationships based on the climatic records of existing weather stations as well as their topographical informations. On 1 km $\times$ 1 km grid cell basis, real time climatic data from the automated weather stations and daily climatic normals were analyzed and graphed. In the future, if several simulation models were developed and connected with this system it would be possible to precisely forecast crop growth and yield or plant disease and pest by using climatic information in alpine area.

  • PDF

A Review on the Sampling and Analytical Methods for Ammonia in Air

  • Das, Piw;Kim, K.H.;Sa, J.H.;Kim, J.C.;Lee, S.R.;Jeon, E.C.
    • Journal of the Korean earth science society
    • /
    • v.28 no.5
    • /
    • pp.572-584
    • /
    • 2007
  • The quantification of ammonia concentrations has received a lot of scientific attention. Numerous devices for the quantification of $NH_3$ in the ambient air have been developed to provide more technical possibilities for research in abating $NH_3$ emission from various source processes. For the proper quantification of $NH_3$, a number of sampling methods have been discussed by grouping them into different categories based on the principle of functioning. In general, active samplers employ pumps to draw air in, while passive samplers are exposed to air over a certain period of time to obtain integrated signature of $NH_3$. In case of the former, impingers and absorption flasks can be employed simultaneously with suitable absorbents to capture $NH_3$ passing through them. The methods of analysis include both in-situ and laboratory determination. In the laboratory, colorimetric or ion chromatographic methods are generally used for its quantification. In the field, a number of real time analyzers have been proven to be useful. These real time analyzers can be grouped according to their principle of operation. These analyzers may use the principle of spectroscopy (e.g. DOAS), photoacousticics (e.g. photoacoustic monitor) or Chemiluminescence ($NO_x$ analyzer). The automated annular denuder sampling system with on-line analyzer is also suitable for continuous monitoring of ammonia in air.

Implementing a Power Facility Management Services using RFID/USN Technology (RFID/USN 기술을 이용한 전력설비관리 서비스 구현)

  • Kim, Young-Il;Shin, Jin-Ho;Song, Jae-Ju;Yi, Bong-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.263-270
    • /
    • 2008
  • Research of ubiquitous computing becomes more popular topic along with the rapid development of wireless technologies. Firstly, research and development on RFID focuses on manufacturing and retail sectors, because it can improve supply chain efficiency. But, it changes to USN (Ubiquitous Sensor Network) by adding a sensor and wireless network technologies on it. In this research, we design and implement the electric facility management service framework to collect real time information of electric facility using RFID/USN. In electric power industry, it is important the supply of energy must be guaranteed. So many power utilities control and supervise the transmission line to avoid power failures. Utilities install many types of sensor to monitor important facilities by wired network such as optical cable and PLC. In this research, we develop the sensor node which is small, easy to install and using wired network. We design the service framework for electric facility management to collect data using RFID tag, reader and wireless sensor nodes and implement the electric facility management service.