• 제목/요약/키워드: On-line mode

검색결과 923건 처리시간 0.04초

철도디젤차량에서 배출되는 오염물질의 배출량 산정방법 개발 (Development of Estimation Methods of Pollutant Emissions from Railroad Diesel Rolling Stocks)

  • 박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.539-553
    • /
    • 2004
  • Up to the present time, many methods to estimate emissions from a particular diesel engines have wholly depended on the quantity of diesel fuel consumed. Then, the recommended emission factors were normalized by fuel consumption, and further total activity was estimated by the total fuel consumed. One of main purposes in the study is newly to develop emission factors for the railroad diesel rolling stock (RDRS) and to estimate a total amount of major gaseous pollutants from the RDRS in Korea. Prior to develop a Korean mode emission factor. the emission factor from the USEPA was simply applied for comparative studies. When applying the USEPA emission factors, total exhaust emissions from the RDRS in Korea were estimated by 28,117tons of NOx, 2,832.3tons of CO, and 1,237.5tons of HC, etc in 2001. In this study, a emission factor for the RDRS, so called the KoRail mode (the Korean Railroad mode) has been developed on the basis of analyzing the driving pattern of the Gyeongbu-Line especially for the line-haul mode. Explicitly to make the site specific emission factors, many uncertainty problems concerning weighting factors for each power mode, limited emission test, incomplete data for RDRS, and other important input parameters were extensively examined. Total exhaust emissions by KoRail mode in Korea were estimated by 10,960tons of NOx, and 4,622tons of CO, and so on in the year of 2001. The emissions estimated by the USEPA mode were 2.6 times higher for NOx, and 1.6 times lower for CO than those by the KoRail mode. As a conclusion, based on the emission calculated from both the USEPA mode and the KoRail mode, the RDRS is considered as one of the significant mobile sources for major gaseous pollutants and thus management plans an(1 control strategies for the RDRS must be established to improve air quality near future in Korea.

오차 자기 순환 신경회로망을 이용한 현가시스템 인식과 슬라이딩 모드 제어기 개발 (Identification of suspension systems using error self recurrent neural network and development of sliding mode controller)

  • 송광현;이창구;김성중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.625-628
    • /
    • 1997
  • In this paper the new neural network and sliding mode suspension controller is proposed. That neural network is error self-recurrent neural network. For fast on-line learning, this paper use recursive least squares method. A new neural networks converges considerably faster than the backpropagation algorithm and has advantages of being less affected by the poor initial weights and learning rate. The controller for suspension systems is designed according to sliding mode technique based on new proposed neural network.

  • PDF

다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석 (Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media)

  • 김윤석
    • 대한전자공학회논문지TC
    • /
    • 제47권8호
    • /
    • pp.61-67
    • /
    • 2010
  • 일반적으로 MIS(도체-부도체-반도체)의 다층 구조로 이루어진 대칭 결합선로에 대한 해석 절차는 모드(even and odd) 해석에 기초한 특성임피던스와 전파상수를 추출함으로서 단층의 결합선로 해석 절차와 동일하다. 본 논문에서는 손실매질의 다층구조로 이루어진 마이크로 스트립선로의 손실특성의 개선을 위한 새로운 구조를 제안한다. MIS 구조로 된 전송선로의 Si와 SiO2층 사이에 0전위를 가진 도체를 일정한 간격의 주기적인 배열로 고안된 새로운 모델의 MIS구조에 대한 유한차분법을 이용한 해석방법이 사용된다. 특히 전송선로에 대한 유전체의 영향을 줄이기 위하여 0전위를 가진 주기적인 결합의 도체로 이루어진 구조가 시간영역의 신호를 통해 시험된다. 다양한 손실률을 가진 불완전 유전체에 따른 주파수 의존적인 추출된 전송선로 파라미터와 등가회로 파라미터가 주파수 함수로서 나타내진다. 특히 본 논문에서 제안한 새로운 구조의 불완전 유전체에 대한 전송선로 파라미터가 주파수 함수로 구해진다.

Small Loop Antenna for EMI Controlled and Monitoring

  • Khemchan, A.;Khamphakdi, P.;Urabe, Junichiro;Khan-ngern, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.470-473
    • /
    • 2004
  • This paper presents conducted emission noise measurement from electronic equipment in frequency range of 1 MHz up to 30 MHz by small loop antenna. Small loop antenna measurement method can measure common-mode (CM) and differential-mode (DM) component of the noise on a pair of power line at the same time. The CM and DM can be measured separately. The theory of this measurement method is introduced and analyzed. The measured results were compared with the conventional measurement by Line Impedance Stabilization Network (LISN) and result a good trend between those methods.

  • PDF

Electromagnetic interference caused by an electric-line current in a cable tray in nuclear power plants

  • Lee, Hoon-Keun;Kim, Yong-Hwa;Choo, Jaeyul
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3314-3318
    • /
    • 2021
  • This paper presents a mode-matching analysis of the electromagnetic coupling between open cable trays in an indoor structure when an electric-line current is generated as an electromagnetic source. We validated the mode-matching method by comparing the mode-matching results with those computed from a commercial electromagnetic simulator and then investigated the strength of the electric-field coupled in a victim cable tray while varying the distances between cable trays and architectural surfaces. The results of this study provide geometrical information on the placement of open cable trays to avoid electromagnetic interference problems.

Line-Source Scattering from Slant Strips

  • Ock, Jang-Soo;Eom, Hyo-Joon
    • Journal of electromagnetic engineering and science
    • /
    • 제9권4호
    • /
    • pp.229-231
    • /
    • 2009
  • Electromagnetic scattering from slant strips excited by a line source is investigated. Boundary conditions are applied to obtain simultaneous equations for discrete modal coefficients. Computations are performed to illustrate the effects of line-source scattering on radiation patterns.

수정된 시크 모드를 이용한 반송용 리니어 DC 모터의 위치제어에 관한 연구 (A study on the Position Control of Linear DC Motor for Carrier by using the modified Seek Mode Control)

  • 임달호;윤상백;이우균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.74-76
    • /
    • 1995
  • This paper describes the precise position control of the linear DC motor for carrier. We analyze the switching line of seek mode control and propose the modified switching line according to the mass and distance. Experimental results demonstrate that good performance is achieved by the proposed controller.

  • PDF

겨울철 동해상의 대상수렴운과 그 주위의 대류운에 관한 WRF 수치모의 연구 (WRF Numerical Study on the Convergent Cloud Band and Its Neighbouring Convective Clouds)

  • 김유진;이재규
    • 대기
    • /
    • 제24권1호
    • /
    • pp.49-68
    • /
    • 2014
  • This study analyzed atmospheric conditions for the convergent cloud band (Cu-Cb line) in developing stage and its neighbouring convections formed over the East Sea on 1 February 2012, by using synoptic, satellites data, and WRF numerical simulation output of high resolution. In both satellite images and the WRF numerical simulation outputs, the Cu-Cb line that stretched out toward northwest-southeast was shown in the East Sea, and cloud lines of the L mode were aligned in accordance with the prevailing surface wind direction. However, those of the T mode were aligned in the direction of NE-SW, which was nearly perpendicular direction to the surface winds. The directions of the wind shear vectors connecting top winds and bottom winds of the moist layers of the L mode and the T mode were identical with those of the cloud lines of L mode and T mode, respectively. From the WRF simulation convection circulations with a convergence in the lower layer of atmosphere and a divergence above 1.5 km ASL (Above Sea Level) were identified in the Cu-Cb line. A series of small sized vortexes (maximum vortex: $320{\times}10^{-5}s^{-1}$) of meso-${\gamma}$-scale formed by convergences was found along the Cu-Cb lines, suggesting that Cu-Cb lines, consisting of numerous convective clouds, were closely associated with a series of the small vortexes. There was an absolute unstable layer (${\partial}{\theta}/{\partial}z$ < 0) between sfc and ~0.3 km ASL, and a stable layer (${\partial}{\theta}/{\partial}z$ > 0) above ~2 km ASL over the Cu-Cb line and cloud zones. Not only convectively unstable layers (${\partial}{\theta}_e/{\partial}z$ < 0) but also neutral layers (${\partial}{\theta}_e/{\partial}z{\approx}=0$) in the lower atmosphere (sfc~1.5 km ASL) were scattered around over the cloud zones. Particularly, for the Cu-Cb line there were convectively unstable layers in the surface layer, and neutral layers (${\partial}{\theta}_e/{\partial}z{\approx}=0$) between 0.2 and ~1.5 km ASL over near the center of the Cu-Cb line, and the neutralization of unstable layers came from the release of convective instability.

슬라이딩 모드 PID 제어법을 이용한 유도 전동기의 위치제어 (Position Control of Induction Motor Using the Sliding Mode PID Control Method)

  • 이윤종;김희준;손영대;장동제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.341-345
    • /
    • 1990
  • This paper presents the three section sliding mode control algorithm based on hysteresis current control add indirect field oriented control method, and applies it to the position control of induction motor. The three section sliding trajectories are defined in such a way that the system responds following a max acceleration line, then a max speed line, and finally a max deceleration line. This control scheme solves the problem of robustness loss during the reaching phase that occurs in conventional VSC strategy, and ensures the stable sliding mode and robustness enhancement throughout an entire response. Also, the PID controller operating in parallel is adopted to eliminate the sliding mode's collapse phenomenon near the origin caused by steady state chattering phenomenon Digital simulation results confirm that the dynamic performance of the system is insensitive to parameter variations and disturbances.

  • PDF

정전류 철도 부하를 이용한 교류 전기 철도 급전 시스템 해석 (Analysis for Autotransformer-Fed AC Electric Railroad System Using Constant Current Mode)

  • 이승혁;정현수;김진오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.329-334
    • /
    • 2001
  • This paper presents exact autotransformer-fed AC electric railroad system modeling using constant current mode. The theory is based on the solution of algebraic. The proposed modeling is considered the line self-impedances and mutual-impedances. Besides, the load modeling improved results are obtained as application to the proposed constant current mode. In the analysis on AT-fed AC electric railroad system circuit, a generalized analysis method using the loop equation on a case by case. the simulation objectives are to calculate the catenary and rail voltages with respect to ground, as the train moves along a section of line between two adjacent ATs. The model contains assumptions regarding the representation of the autotransformer, the impedance of the track/catenary system, and the grounding arrangements, which all effect the accuracy of the result. The modeling results seem very reasonable. It is established that techniques for the AC electric railroad system modeling and analysis.

  • PDF