• 제목/요약/키워드: On-line PD

검색결과 209건 처리시간 0.026초

수력 발전기 권선에서의 운전중 부분방전 측정기법 (On-line partial discharge measurement techniques of hydro-generator windings)

  • 황동하;김진봉;김용주;박명수;김택수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Glucocorticoid Receptor Induced Down Regulation of Metalloproteinase-9 (bfMP-9) by Ginseng Components, Panaxadiol (PD) and Panaxatriol (PT), Contributes to Inhibition of the Invasive Capacity of HTl080 Human Fibrosarcoma Cells

  • Park, Moon-Taek;Cha, Hee-Jae;Jeong, Joo-Won;Kim, Shin-Il;Kim, Kyu-Won
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1998년도 Advances in Ginseng Research - Proceedings of the 7th International Symposium on Ginseng -
    • /
    • pp.224-230
    • /
    • 1998
  • This study showed the anti-invasive activity of ginseng components, panaxadiol (PD) and panamatrlol (PT) on the highly metastatic HT1080 human flbrosarcoma cell line. PD and PT reduced tumor cell invasion through a reconstitute basement membrane in the transwell chamber. A significant down regulation of MMP-9 by PD and PT was detected by northern blot analysis. However, MMP-2 was constantly expressed. Quantitative gelatin based zymography confirmed a marked reduced expression of MMP-9 but not MMP-2 in the treatment of PD and PT. Since the chemical structures of PD and PT are very similar to that of dexamethasone, a synthetic glucocorticoid, it was investigated whether PD and PT act through GR. Western blot analysis and immunocytochemistry showed that PD and PT increased the GR fraction in the nucleus. These results suggest that ursolic acid may induce repression of MMP-9 by stimulating the nuclear translocation of GR and hence inhibiting the activity of AP-1 to TPA-responsible element of MMP-9 promoter region. In conclusion, we suggest that CR-induced down-regulation of MMP-9 by PD and PT contributes to reduce the invasive capacity of HT 1080 cells.

  • PDF

고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발 (Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings)

  • 황돈하;심우용;박도영;강동식;김용주;송상옥;김회동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

초음파 신호측정에 의한 변압기내의 부분방전위치측정 (The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal)

  • 문영재
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1992년도 학술논문발표회 논문집 제11권 1호
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

6.6kV 회전기 부분방전 측정용 Capacitive Coupler 특성 (Characteristics of Capacitive Coupler for Partial Discharge Measurement in 6.6kV Rotating Machines)

  • 강동식;윤대희;김용주;윤영호;이정준;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1619-1622
    • /
    • 2001
  • Recently many researches on the diagnosis of stator winding insulation for large rotating machines have been developed sine the 1970s. Capacitive coupler has been the most widely used sensor for on-line partial discharge(PD) in rotating machines. The 105 [pF] ceramic coupler(CC) has been developed to continuously measure the PD activity in operating motor stator windings. This paper presents frequency characteristics and laboratory test to compare traditional 80 [pF] epoxy-mica coupler(EMC) and 105 [pF] CC for PD measurement in 6.6 [kV] stator windings.

  • PDF

A Study on Automatic Berthing Control of an Unmanned Surface Vehicle

  • Vu, Mai The;Choi, Hyeung-Sik;Oh, Ji-Youn;Jeong, Sang-Ki
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권4호
    • /
    • pp.192-201
    • /
    • 2016
  • This study examined a PD controller and its application to automatic berthing control of an unmanned surface vehicle (USV). First, a nonlinear mathematical model was established for the maneuvering of the USV in the presence of environmental forces. A PD control algorithm was then applied to control the rudder and propeller during an automatic berthing process. The algorithm consisted of two parts, namely the forward velocity control and heading angle control. The control algorithm was designed based on longitudinal and yaw dynamic models of the USV. The desired heading angle was obtained using the "line of sight" method. Finally, computer simulations of automatic USV berthing were performed to verify the proposed controller subjected to the influence of disturbance forces. The results of the simulation revealed a good performance of the developed berthing control system.

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

Variance component analysis of growth and production traits in Vanaraja male line chickens using animal model

  • Ullengala, Rajkumar;Prince, L. Leslie Leo;Paswan, Chandan;Haunshi, Santosh;Chatterjee, Rudranath
    • Animal Bioscience
    • /
    • 제34권4호
    • /
    • pp.471-481
    • /
    • 2021
  • Objective: A comprehensive study was conducted to study the effects of partition of variance on accuracy of genetic parameters and genetic trends of economic traits in Vanaraja male line/project directorate-1 (PD-1) chicken. Methods: Variance component analysis utilizing restricted maximum likelihood animal model was carried out with five generations data to delineate the population status, direct additive, maternal genetic, permanent environmental effects, besides genetic trends and performance of economic traits in PD-1 chickens. Genetic trend was estimated by regression of the estimated average breeding values (BV) on generations. Results: The body weight (BW) and shank length (SL) varied significantly (p≤0.01) among the generations, hatches and sexes. The least squares mean of SL at six weeks, the primary trait was 77.44±0.05 mm. All the production traits, viz., BWs, age at sexual maturity, egg production (EP) and egg weight were significantly influenced by generation. Model four with additive, maternal permanent environmental and residual effects was the best model for juvenile growth traits, except for zero-day BW. The heritability estimates for BW and SL at six weeks (SL6) were 0.20±0.03 and 0.17±0.03, respectively. The BV of SL6 in the population increased linearly from 0.03 to 3.62 mm due to selection. Genetic trend was significant (p≤0.05) for SL6, BW6, and production traits. The average genetic gain of EP40 for each generation was significant (p≤0.05) with an average increase of 0.38 eggs per generation. The average inbreeding coefficient was 0.02 in PD-1 line. Conclusion: The population was in ideal condition with negligible inbreeding and the selection was quite effective with significant genetic gains in each generation for primary trait of selection. The animal model minimized the over-estimation of genetic parameters and improved the accuracy of the BV, thus enabling the breeder to select the suitable breeding strategy for genetic improvement.

다양한 절연열화 분석을 위한 카오스 분석방법 적용 연구 (A POSSIBLE APPLICATION OF CHAOTIC ANALYSIS FOR THE INVESTIGATE OF THE INSULATION DEGRADATION CAUSED BY THE VARIOUS DEFECTS)

  • 윤정훈;임윤석;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1606-1608
    • /
    • 2001
  • In connection with the monitoring of the insulation degradation of the large power apparatus, a statistical treatment, such as phase resolved partial discharge analysis (PRPDA) has been established for the on-line monitoring system during the past two decades. However, it has shown some inconveniences to distinguish the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis(CAPD) is proposed describing the fundamental ideas, outcomes and different view points from conventional PRPDA. In order to make a model for the possible defects causing sudden failures in service, several types of specimen were prepared. And partial discharge signals, originated from those samples, were measured and analyzed by means of PRPDA and CAPD respectively. In this paper, it seems that the correlation between the consecutive PD pulses depending on the nature of PD could be investigated by CAPD. Therefore, it could be considered that the nature of PD source can be distinguished more distinctively when the PRPDA is combined with CAPD.

  • PDF

다양한 결함으로부터 발생되는 절연열화를 검출하기 위한 새로운 접근기법으로써의 카오스 분석 (CHAOTIC ANALYSIS OF PARTIAL DISCHARGE (CAPD) AS A NOVEL APPROACH TO INVESTIGATE INSULATION DEGRADATION CAUSED BY THE VARIOUS DEFECTS)

  • 김성홍;박재준;임윤석;윤정훈;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.221-224
    • /
    • 2001
  • In connection with the monitoring of insulation degradation of large power apparatus in order to predict their unexpected service failures, a statistical treatment, such as phase resolved partial discharge analysis(PRPDA), has been established for the on-line monitoring system during the past decades. However, this method has shown some inconveniences to distinguish the nature of the PD source in power apparatus. In this regard, a novel approach based on the chaotic analysis(CAPD) is proposed describing the fundamental ideas, outcomes and different view points from conventional PRPDA. In order to make a model for the possible defects causing sudden failures in service, several types of specimen were prepared. And partial discharge signals, originated from those samples, were measured and analysed by means of PRPDA and CAPD respectively. Throughout this paper, it seems that the correlation between the consecutive PD pulses depending on the nature of PD could be investigated by CAPD. Therefore, it could be considered that the nature of PD source can be distinguished more distinctively when the PRPDA is combined with CAPD.

  • PDF