• Title/Summary/Keyword: On-line Company

Search Result 459, Processing Time 0.04 seconds

Development and application of on-line lightning information service (온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용)

  • Kwak, J.S.;Woo, J.W.;Kang, Y.W.;Koo, G.S.;Choi, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

Effect of Work Environment and Low Back Pain on the Structural and Muscle Strength Changes in Lumbar Spine (작업환경과 요통이 요추의 구조 및 근력의 변화에 미치는 영향)

  • Kim, Na-Yeon;Kang, Jae-Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.27 no.3
    • /
    • pp.93-104
    • /
    • 2010
  • Objectives : The purpose of this study is to observe the effects of work environment and low back pain on the structural and muscle strength changes in lumbar spine to helpful for preventation and cure of low back pain. Methods : Through measuring of lumbosacral angle, lumbar lordotic angle, lumbar gravity line ratio analyzed structure of lumbar spine and using Trunk Extension Flexion Program of CYBEX NORM System(cybex770+TMC, USA) analyzed Flex. PT, Ext. PT, E/F ratio of lumbar spine of company employees given a medical examination. Results : According to work environment, lumbar gravity line ratio is higher in white collar group than in blue collar group, Ext. PT is significantly lower in white collar group than in blue collar group. According to low back pain or not, lumbar gravity line ratio, Ext. PT is lower in low back pain group than in non-low back pain group. Conclusions : Work environment and low back pain effects on the structural and muscle strength changes in lumbar spine.

Study on Thermal Load Capacity of Transmission Line Based on IEEE Standard

  • Song, Fan;Wang, Yanling;Zhao, Lei;Qin, Kun;Liang, Likai;Yin, Zhijun;Tao, Weihua
    • Journal of Information Processing Systems
    • /
    • v.15 no.3
    • /
    • pp.464-477
    • /
    • 2019
  • With the sustained and rapid development of new energy sources, the demand for electric energy is increasing day by day. However, China's energy distribution is not balanced, and the construction of transmission lines is in a serious lag behind the improvement of generating capacity. So there is an urgent need to increase the utilization of transmission capacity. The transmission capacity is mainly limited by the maximum allowable operating temperature of conductor. At present, the evaluation of transmission capacity mostly adopts the static thermal rating (STR) method under severe environment. Dynamic thermal rating (DTR) technique can improve the utilization of transmission capacity to a certain extent. In this paper, the meteorological parameters affecting the conductor temperature are analyzed with the IEEE standard thermal equivalent equation of overhead transmission lines, and the real load capacity of 220 kV transmission line is calculated with 7-year actual meteorological data in Weihai. Finally, the thermal load capacity of DTR relative to STR under given confidence is analyzed. By identifying the key parameters that affect the thermal rating and analyzing the relevant environmental parameters that affect the conductor temperature, this paper provides a theoretical basis for the wind power grid integration and grid intelligence. The results show that the thermal load potential of transmission lines can be effectively excavated by DTR, which provides a theoretical basis for improving the absorptive capacity of power grid.

Servo Drives State of the Art in Industrial Applications - A Survey

  • Kennel R.;Kobs G.;Weber R.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.321-325
    • /
    • 2001
  • Servo drives with microcomputer control provide the possibility of using modem and sophisticated control algorithms. As an additional feature it is possible to implement parallel and/or redundant software and hardware structures to realise safe motion or similar security functions. Unfortunately microcomputer control also has some impact on the behaviour of servo drives. Control algorithm, cycle time, sensors and interface have to be perfectly synchronised. Special control schemes are necessary on the line side (power supply) to meet the actual requirements concerning EMC. This contribution presents experiences and results obtained from a modem digital drive system pointing out the influences of low and high accuracy position sensors and the interdependencies mentioned above.

  • PDF

Various underwriting methods through case audit (증례점검 사례를 통한 다양한 언더라이팅 접근 방향 모색)

  • Choi, So-Yung
    • The Journal of the Korean life insurance medical association
    • /
    • v.27 no.1
    • /
    • pp.18-20
    • /
    • 2008
  • I have taught various case audit underwriting methods to underwriters for many years. Underwriting requires specialized medical knowledge and experience of comprehensive individual risk analysis. Decisions in individualized underwriting depend on the insurance company's management philosophy and vision, marketing strategies, culture, product line etc. They also depend on the information acquired through proposal forms, inspection reports, laboratory results and disclosures. Underwriters match this acquired information to each insurance product, search appropriate medical resources, assess the probabilities of future claims, and decide what, if any, further medical information should be gathered. Sources include doctors' reports, medical records, biopsies, blood and urine tests, CT, MRI, Holter monitoring, sonography etc. Insurance medical directors help and teach underwriters to analyze individual medical risks and make effective.

  • PDF

Research on Friction Characteristics of Constant Velocity Joint Grease (등속조인트용 그리스 마찰특성 연구)

  • Lee, Sung Uk;Bae, Dae Yoon
    • Tribology and Lubricants
    • /
    • v.29 no.4
    • /
    • pp.223-227
    • /
    • 2013
  • A GAF (generated axial force) is produced at a plunging-type CVJ (constant velocity joint). A high GAF can cause vibrations in a vehicle. Grease is used to reduce friction between the roller and the track of the outer case of a CVJ. The grease performance depends on the surface conditions and operating temperature. The surface of the outer case is extremely rough and hard. In recent times, the maximum operating temperature of CVJs has crossed $140^{\circ}C$, because the exhaust line is now located close to the CVJ. In this study, we examined the friction characteristics of friction additives at $25-150^{\circ}C$ and determined an optimal formulation with a low friction coefficient. This formulation can be used to develop low-friction grease that can reduce the GAF produced at a CVJ by approximately 7-26%.

Analysis of OLAP-based CRM Development Strategies and Effects (OLAP 기반의 CRM 개발전략 및 효과에 관한 연구 유통산업의 사례를 중심으로)

  • 조남재;이용범;정창미
    • Proceedings of the Korea Database Society Conference
    • /
    • 2001.06a
    • /
    • pp.251-260
    • /
    • 2001
  • For a continuous revenue increase, a new scheme to increase sale volume is a necessity. This new scheme is based on a revaluation of the customer value for the sake of the future of a company. The concept and use of CRM and OLAP(On-Line Analytical Processing) are introduced in this report. The effectiveness of OLAP-based CRM is demonstrated through a case study of a typical retail company. The research suggests the need for the establishment of a marketing strategy to build a long-term relationship with individual customers. The needs for a scientific and systematic analysis of the industry, competitors and customers are elaborated.

  • PDF

Design of an Input-Parallel Output-Parallel Multi-Module DC-DC Converter Using a Ring Communication Structure

  • Hu, Tao;Khan, Muhammad Mansoor;Xu, Kai;Zhou, Lixin;Rana, Ahmad
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.886-898
    • /
    • 2015
  • The design feasibility of a micro unidirectional DC transmission system based on an input-parallel output-parallel (IPOP) converter is analyzed in this paper. The system consists of two subsystems: an input-parallel output-series (IPOS) subsystem to step up the DC link voltage, and an input-series output-parallel (ISOP) subsystem to step down the output voltage. The two systems are connected through a transmission line. The challenge of the delay caused by the communication in the control system is addressed by introducing a ring communication structure, and its influence on the control system is analyzed to ensure the feasibility and required performance of the converter system under practical circumstances. Simulation and experiment results are presented to verify the effectiveness of the proposed design.

A Study on the Process Improvement of Commutator Press Fitting by 6 Sigma Process (6시그마 프로세스를 이용한 정류자(Commutator) 압입 공정개선에 관한 연구)

  • Cheong, Seon-Hwan;Choi, Seong-Dae;Yang, Se-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.2
    • /
    • pp.37-42
    • /
    • 2005
  • Recently $6{\sigma}$ quality control is an most important strategy to many enterprises in order to be a top company in the world, because it is an excellent scientific method to achieve the best quality control for their management and products. SY company is a small and medium one that has the quality problem for a long time such as occurring cracks on the surface of commutator at his assembly line while being assembled a rotor shaft and commutator of DC motor. This research was started to improve this problem by $6{\sigma}$ process, and as the results of this study, first, to find three vital fews, second, to get an achievement of about 21% improvement for the fracture strength of commutator, and third, to be recognized to change into $6{\sigma}$ quality control in SY company.

  • PDF