• Title/Summary/Keyword: On-current

Search Result 53,856, Processing Time 0.061 seconds

A Study on the Stimulus Properties of Arac. acid and Phospholipid Organic Monolayer (Arac. acid와 인지질 유기단분자의 자격특성에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.104-107
    • /
    • 2000
  • It is well known that the state of existence of molecules on the surface of water changes during compression of the molecules. Electric methods, such as the measurement of the surface potential or displacement current, are also useful for investigating dynamic changes of the molecular state on the water surface during compression. Maxwell-Displacement-Current(MDC) measuring technique has been applied to the study of monolayers of Arachidic acid and L-$\alpha$-Dimyristoyl Phosphatidylcholine(L-$\alpha$-DMPC). The displacement current was generated from monolayers on a water surface by monolayer compression. Displacement current was generated in the gas state, gas/liquid state, and liquid state in the course of monolayer compression. The researchers examined diplacement current of electric conduction organic monolayer generated due to orient change of monolayers alkylchain.

  • PDF

A case study of remote wireless monitoring system for stray current due to subway system (지하철 누설전류 무선 원격 감시시스템 적용 사례)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

A Study on Current Blocking Configuration of V-Groove Quantum Wire Laser (V형 양자선 레이저의 전류 차단층에 대한 연구)

  • 조태호;김태근
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1268-1272
    • /
    • 2003
  • In order to enhance current Injection efficiency of Y-groove inner strife(VIS) quantum wire lasers, three different current configurations, n-blocking on p-substrate(VIPS), p-n-p-n blocking on n-substrate(VI(PN)nS), p-blocking on n-substrate(VINS) have been designed and fabricated. Among them VIPS laser showed the most stable characteristics of lasing up to 5 mW/facet, a threshold current of 39.9 mA at 818 nm, and an external differential quantum efficiency of 24 %/facet. The current tuning rate was almost linear 0.031 nm/mA, and the temperature tuning rate was measured to be 0.14 nm/$^{\circ}C$.

The Effect of Train Motion on Dynamic Characteristics of Current Collection System (고속전철의 주행조건이 집전계의 동특성에 미치는 영향)

  • Kim Jung-Soo
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.1 s.32
    • /
    • pp.18-22
    • /
    • 2006
  • The dynamic characteristics of the current collection system are investigated by conducting a test run in which signals from accelerometers and load cells attached to the various parts of the pantograph are analyzed in both the time and frequency domains. The dynamic characteristics of the current collection system are found to be strongly influenced by the train speed; the fluctuation in the pantograph motion increases in direct proportion to the train speed. There exist two major fequency components in the pantograph motion related to the current collection, a speed-dependent component arising from the train traversing a span of the catenary, and a speed-independent component related to the pantograph resonant frequency. The train acceleration is also found to exert strong influence on the current collection system characteristics. The effect of the train motion is found to be stronger on the speed-dependent frequency component than on the speed-independent one.

A Commutation Torque Ripple Reduction for Brushless DC Motor Drives

  • Won, Chang-hee;Song, Joong-Ho;Ick Choy
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.174-182
    • /
    • 2002
  • This paper presents a comprehensive study on reducing commutation torque ripples generated in brushless DC motor drives with only a single do-link current sensor provided. In such drives, commutation torque ripple suppression techniques that are practically effective in low speed as well as high speed regions are scarcely found. The commutation compensation technique proposed here is based on a strategy that the current slopes of the incoming and the outgoing phases during the commutation interval can be equalized by a proper duty-ratio control. Being directly linked with deadbeat current control scheme, the proposed control method accomplishes suppression of the spikes and dips superimposed on the current and torque responses during the commutation intervals of the inverter. Effectiveness of the proposed control method is verified through simulations and experiments.

Estimation of Delta Winding Current and Its Application to a Compensated-Current-Differential Relay for a Y-Δ Transformer

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, En-Shu
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.255-263
    • /
    • 2010
  • The compensated-current-differential relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Delta winding current is necessary to obtain the modified differential current for a $Y-\Delta$ transformer. This paper describes an estimation algorithm of the delta winding current and its application to a compensated-current-differential relay for a $Y-\Delta$ transformer. Prior to saturation, the core-loss current is calculated and used to modify the differential current. When the core first enters saturation, the initial value of the core flux is obtained by inserting the modified differential current into the magnetization curve. This flux value is used to derive the magnetizing current and consequently the modified differential current. The operating performance of the proposed relay was compared against a conventional current differential relay with harmonic blocking. Test results indicate that the proposed relay remained stable during severe magnetic inrush and over-excitation, and its operating time is significantly faster than a conventional relay. The relay is unaffected by the level of remanent flux and does not require an additional restraining or blocking signal to maintain stability. This paper concludes by implementing the proposed algorithm into a prototype relay based on a digital signal processor.

A Study on the Supply and Stray Current Distribution of the DC Railway Power System (직류전기철도 급전시스템에서 공급 및 누설전류 분포에 관한 연구)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.160-168
    • /
    • 2010
  • This paper presents the analysis of the current as stray current and supplied current of the substation, on the DC railway power system. In DC railway power supply system, the running rails are usually used as the return conductor(negative-polarity) for traction load current. This condition mainly focuses on economic considerations, since it does not require the installation of an additional return conductor. But, problems of low resistance between the running rails for the return conductor and earth allows a significant part of the return load current to leak into the earth. This current is normally called to as leakage or stary current. This stary currents creates serious problems for any electrified matter in the underground. Therefore, reduction of stray current of the DC railway power supply system is also of direct benefit to the operational and safety aspects of the DC railway systems. In this paper, deal with the analysis of the current distribution on the DC railway power system applied the common grounding system, using SPLIT of CDEGS program.

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.

Current Effect on the Motion and Drift Force of Cylinders Floating in Waves (주상체(柱狀體)의 운동(運動) 및 표류력(漂流力)에 미치는 해류(海流)의 영향(影響))

  • Sei-Chang,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.23 no.4
    • /
    • pp.25-34
    • /
    • 1986
  • A two-dimensional linear method has been developed for the motion and the second-order steady force arising from the hydrodynamic coupling between waves and currents in the presence of a body of arbitrary shape. Interaction between the incident wave and current in the absence of the body lies in the realm beyond our interest. A Fredholm integral equation of the second kind is employed in association with the Haskind's potential for a steadily moving source of pulsating strength located in or below the free surface. The numerical calculations at the preliminary stage showed a significant fluctuation of the hydrodynamic forces on the surface-piercing body. The problem is approximately solved by using the asymptotic Green function for $U^2{\rightarrow}0$. The original Green function, however, is applied for the fully submerged body. Numerical calculations are made for a submerged and for a half-immersed circular cylinder and extensively for the mid-ship section of a Lewis-form. Some of the results are compared with other analytical results without any available experimental data. The current has strong influence on roll motion near resonance. When the current opposes the waves, the roll response are generally negligible in the low frequency region. The current has strong influence on roll motion near resonance. When the current opposes the wave, the roll response decreases. When the current and wave come from the same direction, the roll response increases significantly, as the current speed increases. The mean drift forces and moment on the submerged body are more affected by current than those on the semi-immersed circular cylinder or on the ship-like section in the encounter frequency domain.

  • PDF