• Title/Summary/Keyword: On-Line Testing

Search Result 566, Processing Time 0.03 seconds

Development of Hardware In-the-Loop Simulation System for Testing Power Management of DC Microgrids Based on Decentralized Control (분산제어 기반 직류 마이크로그리드 전력관리시스템의 HIL 시뮬레이션 적용 연구)

  • To, Dinh-Du;Le, Duc-Dung;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.191-200
    • /
    • 2019
  • This study proposes a hardware-in-the-loop simulation (HILS) system based on National Instruments' PXI platform to test power management and operation strategies for DC microgrids (MGs). The HILS system is developed based on the controller HIL prototype, which involves testing the controller board in hardware with a real-time simulation model of the plant in a real-time digital simulator. The system provides an economical and effective testing function for research on MG systems. The decentralized power management strategy based on the DC bus signaling method for DC MGs has been developed and implemented on the HILS platform. HILS results are determined to be similar to those of the off-line simulation in PSIM software.

A Technical Trend on UHF Techniques for On-Line PD Monitoring and Site Testing for Transformer (전력용 변압기의 온라인 PD 모니터링과 시험을 위한 UHF 기술 동향)

  • Kim, Byung-Woo;Kim, Yun-Seok;Kim, Chang-Bok;Cho, Soo-Young;Choi, Young-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1972-1973
    • /
    • 2007
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a transformer. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Performance Testing of Composite Web-Service with Aspect-Based WS-BPEL Extension

  • Kim, Jong-Phil;Sung, Dong-Hyuk;Hong, Jang-Eui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.10
    • /
    • pp.1841-1861
    • /
    • 2011
  • The advance in Service-Oriented Architecture (SOA) and web services has led to the development of new types of a system in which heterogeneous service components can connect and compose to solve a complex business problem. In the SOA, even though these service components are valid in their functionality, there is a need to test their behaviors when those services are composited. In recent years, WS-BPEL has received a wide acceptance as a means of integrating distributed service components. To test the composite service, the existing testing techniques have been focused on the functional features based on the WS-BPEL process. However as SOA approach is applying to real-time software development, the performance of composite service becomes one of important issues. This paper proposes a technique to the performance testing of a composite service with WS-BPEL extension which combined with the concept of aspect. Our WS-BPEL extension has been made towards annotating aspect component which is measuring the response time of the composite service. This paper also explains the procedure of performance testing with on-line transaction system. Our technique can apply to choose an adequate component in service composition with considering the performance among several candidate web service components.

A case study of a testing duties of on-line games (온라인게임 테스트 직무에 관한 사례 연구)

  • Eun, Kwang-Ha;Lee, Dong-Lyeor
    • Journal of Digital Convergence
    • /
    • v.10 no.1
    • /
    • pp.435-443
    • /
    • 2012
  • Online game has been made of total products which user was given the experimental properties of a variety such as fun and the total of hardware and software products. Through this processes, The company earned a profitable benefits, in addition to the user was given satisfactory service. In this sense the parts of the game production process, the service earlier in the game testing a variety of ways needs to the user through the game as a condition for providing the content can be. Contact a professional game testing job is done systematically through the game's completion of a game developed by companies to see that service to complement previous significant. In this study, search for independent testing cases and the systematical cases as experts needs a range of the testing services.

Construct Test Line of Light Rail Transit for Overall Test and Commissioning (경량전철 기술개발 종합시험을 위한 시험선로 건설 사례)

  • Lee, An-Ho;Lee, Duck-Young
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1118-1123
    • /
    • 2004
  • Launched in 1999 and funded by the Korean government, the R&D project of developing the. light train system technology is finally wrapped up to produce its prototype train prototype and all the research activities on signal, communication, power supply third rail Type and infra-structure have been completed. In an attempt to verify the usability of the system through an actual testing and as a preliminary step to the application of the system to overall light train construction projects to be implemented in different cities in Korea, testing lines are under construction now. Here we'd like to introduce people to the general overview of the test line construction and interface found in the process of project.

  • PDF

Recent Development in Ultrasonic Guided Waves for Aircraft and Composite Materials

  • Rose, Joseph L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.525-533
    • /
    • 2009
  • Emphasis in the paper is placed on describing guided wave successes and challenges for applications in aircraft and composite materials inspection. Guided wave imaging methods discussed includes line of sight, tomography, guided wave C-scan, phased array, and ultrasonic vibration methods. Applications outlined encircles lap splice, bonded repair patch, fuselage corrosion, water loaded structures, delamination, and ice detection and de-icing of various structures.

On-Line Partial Discharge Detecting Method for Insulation Diagnosis of High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 절연진단을 위한 운전중 부분방전 측정기법)

  • Hwang, D.H.;Shin, B.C.;Sim, W.Y.;Park, D.Y.;Kim, Y.J.;Song, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1727-1729
    • /
    • 2001
  • Partial discharge testing are rapidly becoming the most powerful tool to assess the condition of high voltage generator and motor stator windings. Recently, on-line monitoring scheme with trending technique is widely applied in insulation diagnosis. This paper describes the on-line partial discharge detecting techniques in the high voltage motor stator windings. Also, on-line monitoring system for an insulation diagnosis are proposed.

  • PDF

A Design Methodology on Signal Paths for Enhanced Signal Integrity of High-speed Communication System and a BIST Design for Backplane Boards Testing (고속 통신 시스템의 신호충실성 향상을 위한 선로 설계 방법론 및 Backplane Boards Testing를 위한 BIST 설계)

  • Jang, Jong-Gwon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1263-1270
    • /
    • 2000
  • The operation frequency of High-speed Communication System becomes very fast with the advanced technology of VLSI chips and system implementation. There may exist various types of noise sources degrading the signal integrity in this system. The present main system is made of backplane, so faults can be brought whenever a board is removed, replaced or added. This backplane boards testing is a very important process to verify the operation of system. firstly, we model the effects of the internal noises in the High-speed Communication System to the signal line and propose a new design method to minimize these effects. For the design methodology, we derive the characterization value for each mode land them construct the optimal simulation model. We compare the result of own proposing method with that fo the existing methods, through simulation and show that the quality of High-speed Communication System is significantly enhanced. Secondary our proposing BIST for the Backplane Boards Testing is designed to guarantee that there is no fault in the high-speed communication system.

  • PDF

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.