• 제목/요약/키워드: On-Center

검색결과 73,669건 처리시간 0.072초

Delayed Surgical Management of Traumatic Pseudoaneurysm of the Ascending Aorta in Multiple Trauma

  • Ma, Dae Sung;Kim, Sung Jin;Joo, Seok;Hyun, Sung Youl;Jeon, Yang Bin
    • Journal of Trauma and Injury
    • /
    • 제31권1호
    • /
    • pp.29-33
    • /
    • 2018
  • Traumatic blunt aortic injury especially on proximal ascending aorta is a rare injury with a few reports. Generally emergency surgical management was performed. In this case, however, in multiple trauma with brain injury, emergency surgical management of aortic injury might result in unexpected secondary injury of the brain. Herein, we report a case of a 33-year-old man who was driving a truck was injured in a head-on collision. Evaluation revealed a pseudoaneurysm on his ascending aorta concomitant with epidural hemorrhage. He was treated by surgical management of his ascending aorta after 3 days from accident. There were no postoperative and neurologic complications and the patient was discharged after 18 days.

공동체 복합지원시설인 주민자치센터의 복합화 현황 및 특성에 관한 연구 - 서울시를 중심으로 - (A Study on the Present Complex Conditions and Characteristics of Community Centers - Focused on the Seoul Metropolis -)

  • 이미숙;서귀숙
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.280-284
    • /
    • 2008
  • This study is a research for revitalized characteristics of compounded community center which is a complex aid facility with a key position of regional culture and welfare. Recent complex conditions of community center and public facility is studied on this research. The methods are searches in the Internet, telephone interviews, and documents of present local conditions. The results are as follow : The community center in Seoul City support 2 million people per a center in average and self-supporting financial rate came out low. The community center formed physical shape in one building with community facilities. A district complex community center type, which is a village office united to public facilities, expected to be increased. The community center compound 1 or 2 facilities, divided 15 types. Most of community center is complex type of community center with village office and the other types are complex type of community center with a hall for the aged, nursery, and library. Accordingly, the community center keeps up the complex type of community center with village office type as a physical shape in one building and the district complex community center type complexes with hall for the aged, nursery and library.

  • PDF

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

도심 어린이집 주변 도로상 대기오염도 특징 (On-road Air Pollution Characteristics around a Day-care Center in Urban Area)

  • 우성호;이승복;김경환;이광재;류성희;김종범;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.61-75
    • /
    • 2014
  • Five on-road measurements were made using a mobile laboratory (ML) to characterize spatial and temporal air pollutant distributions over roads around a day-care center in urban area on 30 August 2013. Fixed monitoring was also done near the day-care center using the ML during the periods between on-road measurements. On-road air pollution monitoring route was classified into seven sections and three zones to identify severe polluted roads among many roads having different traffic volumes and directions. Typical pollutants emitted from vehicles such as $NO_x$, black carbon, particle-bound polycyclic aromatic hydrocarbons, and submicron particles including nanoparticles were monitored using real-time instruments. Peak concentration episodes were frequently observed during the on-road measurements and most peaks were simultaneously monitored at four pollutants. Colored on-road air pollution map for each pollutant provides an insight on spatial air pollution distribution, showing heavily polluted roads and sections. Average on-road $NO_x$ concentration of each run was similar to that monitored at the nearest roadside air monitoring station.

Center-body 디퓨져 형상설계를 위한 수치적연구 (Numerical Study for Design of Center-body Diffuser)

  • 김종록;김재수
    • 한국추진공학회지
    • /
    • 제18권3호
    • /
    • pp.34-39
    • /
    • 2014
  • center-body디퓨져에 대한 형상 설계 요소를 분석하고 수치적 기법을 통한 설계형상 변수를 구성하였다. 수치기법으로는 Center-body 디퓨져의 내부유동해석을 위하여 2차원 축대칭 Navier-Stokes equation와 $k-{\epsilon}$ 난류모델을 사용하였다. 또한 center-body디퓨져의 시동압력과 진공도 및 형상설계변수에 대해서 2차목 디퓨져와 비교하였다. 냉각시스템의 성능향상 방안으로 CBD의 원추선단에 역류제트를 활용한 TPS시스템의 개념을 제시하였다.

Highly Robust Bendable a-IGZO TFTs on Polyimide Substrate with New Structure

  • Kim, Tae-Woong;Stryakhilev, Denis;Jin, Dong-Un;Lee, Jae-Seob;An, Sung-Guk;Kim, Hyung-Sik;Kim, Young-Gu;Pyo, Young-Shin;Seo, Sang-Joon;Kang, Kin-Yeng;Chung, Ho-Kyoon;Berkeley, Brain;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.998-1001
    • /
    • 2009
  • A new flexible TFT backplane structure with improved mechanical reliability is proposed. Amorphous indium-gallium-zinc-oxide (a-IGZO) thin film transistors based on this structure have been fabricated on a polyimide substrate, and the resultant mechanical durability has been evaluated in a cyclic bending test. The panel can withstand 10,000 bending cycles at a bending radius of 5 mm without any noticeable TFT degradation. After 10K bending cycles, the change of threshold voltage, mobility, sub-threshold slope, and gate leakage current were only -0.22V, -0.13$cm^2$/V-s, -0.05V/decade, and $-3.05{\times}10^{-13}A$, respectively.

  • PDF

4.1” Transparent QCIF AMOLED Display Driven by High Mobility Bottom Gate a-IGZO Thin-film Transistors

  • Jeong, J.K.;Kim, M.;Jeong, J.H.;Lee, H.J.;Ahn, T.K.;Shin, H.S.;Kang, K.Y.;Park, J.S.;Yang, H,;Chung, H.J.;Mo, Y.G.;Kim, H.D.;Seo, H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.145-148
    • /
    • 2007
  • The authors report on the fabrication of thin film transistors (TFTs) that use amorphous indium-gallium-zinc oxide (a-IGZO) channel and have the channel length (L) and width (W) patterned by dry etching. To prevent the plasma damage of active channel, a 100-nm-thckness $SiO_{x}$ by PECVD was adopted as an etch-stopper structure. IGZO TFT (W/L=10/50${\mu}m$) fabricated on glass exhibited the high performance mobility of $35.8\;cm^2/Vs$, a subthreshold gate voltage swing of $0.59V/dec$, and $I_{on/off}$ of $4.9{\times}10^6$. In addition, 4.1” transparent QCIF active-matrix organic light-emitting diode display were successfully fabricated, which was driven by a-IGZO TFTs.

  • PDF

다중 부하중심점에 기반한 온라인 퍼지 ULTC 제어기 설계에 대한 연구 (A Study on the On-Line Fuzzy ULTC Controller Design Based on Multiple Load Center Points)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.514-521
    • /
    • 2006
  • The existing ULTC operation control strategy based on the measured data deteriorates the voltage compensation capability making the efficient corresponding to the load variation difficult by following the fixed load center point voltage. Accordingly, this paper proposes a new on-line fuzzy ULTC controller based on the designed multiple load center points which can improve the voltage compensation capability of ULTC and minimize voltage deviation by moving in real-time the load center point according to the load variation to an adequate position among the multiple load center points designed using the clustering technique. The Max-Min distance technique is adopted as the clustering technique for the decision of multiple load points from measured MTr load current and PTr voltage, and the minimum distance classifier is adopted for the decision of fuzzy output membership function. To verify the effectiveness of the proposed strategy, Visual C++ MFC-based simulation environments is developed. Finally, the superiority the proposed strategy is proved by comparing the fuzzy ULTC operation control results based on multiple load center points with the existing ULTC operation control results based on fixed load center point using the data for three day.

U-민원 콜센터 상담원 조직 공정성이 조직몰입과 직무만족을 통해 직무성과에 미치는 영향 (U-complaints call center agents organization fairness impact on job performance through organizational commitment and job satisfaction)

  • 남상민;황찬규;권두순;홍순근
    • 디지털산업정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.125-143
    • /
    • 2015
  • As improving the life quality of citizen because of development of Urbanization and Information, civil application service of public institutions has been changed. The government provides a 24-hour civil service of e-government, public institutions operate U-complaints call center to pursue a personalized service to customers. As customer service are diversified, the inconvenience of service is increased. Therefore, public institutions instituted U-complaints call center to solve increased complaints. In early days, public institutions operated simple call center. However, it became intelligent U-complaints call center by SNS. The more increase the importance of agents' contact customer service, the more increase Job Performance considered by Organizational Commitment & Job Satisfaction of call center agents. This study analyzed that applied to Fairness Theory with Organizational Commitment, Job Satisfaction and analyze U-complaints call center agents' role and job performance of public institutions. Proposed a research model applied to job satisfaction with key variables, organizational commitments, job satisfaction. It's expected to impact on job performance of U-complaints call center agents in public institutions. For empirical study of research model, conducted a survey of the U-complaints call center agents of public institutions. 170 samples were collected from the survey and analyze relationship between the factors. Procedural justice, distribution fairness, fairness interaction are significant influence on organizational commitment of parameters by analysis U-complaints call center agents. Procedural justice and fairness of interaction was found not to effect on parameters of job satisfaction. Also, parameter, organizational commitment have significant influence on job satisfaction. However, have no influence on job performance. Therefore, the parameters of job satisfaction have significant influence on job performance. Public institutions should adopt to improve the quality of citizen services through U-complaints call center agents.